background image

Installation—K16005 

 

11 

Step One:  Disconnect pump from power supply 

 

Step Two:  Disconnect inlet and outlet fittings from pump 

 

Remove steel clips from inlet and outlet ports of the pump. 

 

Pull inlet and outlet fittings out of the pump.  Do not disconnect hoses from 

fittings. 

 

Step Three:  Remove pump from sprayer 

 

Remove four screws from pump mounting feet.   

 

Remove pump from sprayer. 

 

Step Four:  Assemble fittings to regulator 

 

Remove steel clips from outlet  

and bypass ports of regulator. 

 

Install QC x 3/8" HB fitting 

into bypass port of  

regulator. To insert quick connect 

fittings, lubricate O-ring with 

water and twist fitting while 

inserting into pump port. Secure 

with steel clip.  

 

Thread pressure gauge into 1/4"  

NPT port on front side of  

regulator (the side of the  

regulator with the “BYPASS”  

label). 

 

Thread 1/4" NPT plug   

into 1/4" NPT port on back side  

of regulator. 

 

Install QC x 3/8" HB, elbow              

into outlet port of  

             

regulator. To insert quick connect 

fittings, lubricate O-ring with 

water and twist fitting while 

inserting into pump port. Secure 

with steel clip. 

Step Five:  Assemble regulator and fittings to pump 

 

Install inlet port of the regulator into outlet port of the pump.  Secure with steel 

clip. 

 

Turn regulator to orient knob toward the top of the pump. 

 

Step Six:  Drill hole in tank 

 

Align the four circles on the supplied drill template sheet with the pump mounting 

holes on the sprayer tank. 

 

Using a 9/16" drill bit (not included) drill a hole through the top of the tank in the 

position indicated by the appropriate X on the template.   

 

Remove plastic debris from inside the tank (if chemicals have been used inside 

the tank, refer to pg. 18 step 4 for personal decontamination after removing 

debris). 

 

Summary of Contents for K16003

Page 1: ...Specifications...

Page 2: ...ts Pesticides are especially toxic to them DO NOT TURN ON POWER to sprayer until ready to spray in order to avoid unintentional spray release Improper use of the sprayer or handling of chemicals could...

Page 3: ...Hazard Signal Word Definitions 3...

Page 4: ...er Identification 7 Installation K16005 10 K16006 K16007 12 Checking Installation 14 Operation Preparing the Regulator for Each Use 15 Using the Regulator Step One Assess wind conditions and clear wor...

Page 5: ...in spraying pesticides in dry or aerosolized form or for use with fumigants SPRAYING OTHER LIQUIDS In addition to spraying pesticides this regulator may be used to spray other non flammable liquids Ex...

Page 6: ...s Pesticides are especially toxic to them Keep sprayer and spray materials away from them at all times DO NOT MIX OR POUR chemicals in an enclosed unventilated area DO NOT USE flammable or corrosive c...

Page 7: ...include a Eyes immediately flush with water b Skin wash all contaminated skin surfaces with soap and water c Clothing remove contaminated clothing Dispose of heavily contaminated clothing per chemical...

Page 8: ...nents please contact Kincrome Customer Service on 1300 657 528 Regulator Grommet Screw 4 QC Clip Pressure Gauge QC x 3 8 HB Elbow QC x 3 4 HB Elbow QC x 1 2 HB Elbow 50 QC x 3 8 HB Straight QC x 1 2 H...

Page 9: ...r Identification 9 Drill Template Sheet Use the four circle template when drilling the pump mounting holes on the sprayer tank The position of the holes needed for each sprayer model is indicated by a...

Page 10: ...may require a suitable thread sealer applied sparingly DO NOT over tighten maximum torque is 45 in lb 5 N m Tubing should be compatible with the spraying fluid At least 18 450mm length is suggested t...

Page 11: ...he side of the regulator with the BYPASS label Thread 1 4 NPT plug into 1 4 NPT port on back side of regulator Install QC x 3 8 HB elbow into outlet port of regulator To insert quick connect fittings...

Page 12: ...Press bypass fitting into the grommet Reinstall four screws through pump feet and into threaded holes in the tank Step Nine Reinstall hoses Install fitting on inlet hose into inlet port of the pump T...

Page 13: ...fitting removed from outlet fitting in Step Two into 1 4 NPT port on front side of regulator the side of the regulator with the BYPASS label Thread pressure gauge into 1 4 NPT port on back side of reg...

Page 14: ...s bypass fitting into the grommet Reinstall four screws through pump feet and into threaded holes in the tank Step Nine Reinstall hoses Install fitting on inlet hose into inlet port of the pump To ins...

Page 15: ...ry terminals Step Two Check and test completed assembly WARNING Check and test completed assembly Serious injury could result from chemical leaks if regulator is improperly assembled or the design of...

Page 16: ...cing the regulator Replacement parts If a part needs replacement only use parts that meet the manufacturer s specifications Replacement parts that do not meet specifications may result in a safety haz...

Page 17: ...bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the regulator WARNING ALWAYS wear personal protective equipment as directed on the chem...

Page 18: ...until the desired setting is reached Note If the pressure is still too low when the regulator knob is completely tightened smaller or fewer nozzles need to be used 7 Discontinue use if clogged or ino...

Page 19: ...de is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to be...

Page 20: ...eeze into the pump system Some antifreeze contain Ethanol which is alcohol based and highly flammable which should not be used 2 Spray briefly Turn on the pump and run the pump system briefly until fl...

Page 21: ...ensure the chemical is compatible with all materials in the system Note The regulator is not compatible with bleach or chlorine products Also pumping any petroleum based fluid gasoline diesel kerosen...

Page 22: ...K16140 Quick Connect x 3 8 Hose barb K16141 Quick Connect x 1 2 Hose barb K16142 Quick Connect x 1 2 MNPT K16143 Quick Connect x 3 8 Hose barb elbow K16144 Quick Connect x 1 2 Hose barb elbow Quick C...

Page 23: ...f this product has materials or workmanship defects other than defects caused by abnormal or non warranted use you can at your cost send the product to place of purchase an authorised Kincrome service...

Page 24: ...24 Page intentionally left blank...

Page 25: ...25...

Reviews: