Installation—K16005
11
Step One: Disconnect pump from power supply
Step Two: Disconnect inlet and outlet fittings from pump
Remove steel clips from inlet and outlet ports of the pump.
Pull inlet and outlet fittings out of the pump. Do not disconnect hoses from
fittings.
Step Three: Remove pump from sprayer
Remove four screws from pump mounting feet.
Remove pump from sprayer.
Step Four: Assemble fittings to regulator
Remove steel clips from outlet
and bypass ports of regulator.
Install QC x 3/8" HB fitting
into bypass port of
regulator. To insert quick connect
fittings, lubricate O-ring with
water and twist fitting while
inserting into pump port. Secure
with steel clip.
Thread pressure gauge into 1/4"
NPT port on front side of
regulator (the side of the
regulator with the “BYPASS”
label).
Thread 1/4" NPT plug
into 1/4" NPT port on back side
of regulator.
Install QC x 3/8" HB, elbow
into outlet port of
regulator. To insert quick connect
fittings, lubricate O-ring with
water and twist fitting while
inserting into pump port. Secure
with steel clip.
Step Five: Assemble regulator and fittings to pump
Install inlet port of the regulator into outlet port of the pump. Secure with steel
clip.
Turn regulator to orient knob toward the top of the pump.
Step Six: Drill hole in tank
Align the four circles on the supplied drill template sheet with the pump mounting
holes on the sprayer tank.
Using a 9/16" drill bit (not included) drill a hole through the top of the tank in the
position indicated by the appropriate X on the template.
Remove plastic debris from inside the tank (if chemicals have been used inside
the tank, refer to pg. 18 step 4 for personal decontamination after removing
debris).
Summary of Contents for K16003
Page 1: ...Specifications...
Page 3: ...Hazard Signal Word Definitions 3...
Page 24: ...24 Page intentionally left blank...
Page 25: ...25...