31
control mode and the drive’s status before power failure.
See Table 6-1.
Table 6-1 Restarting conditions
Settin
g of
A1.10
Status
before
power
off
Panel
Serial
port
3-wire
modes
1 and
2
2-wire
modes 1
and 2
Without control command
With
0
Stop
0
0
0
0
0
Run
0
0
0
0
0
1
Stop
0
0
0
0
1
Run
1
1
1
0
1
Table 6-1 shows the drive’s action under different
conditions. ―0‖ means the drive enter ready status and
―1‖ means the drive start operation automatically.
Note:
1.When using the panel or serial port or 3-wire mode 1
and 2 to start or stop the drive, the command signal is in
pulse mode and there is no operating command when the
drive is switched on.
2.If there is a stopping command, the drive will stop
first. 3.When the function of restart after power failure is
enabled, the drive will start on the fly after power on if it
is not switched off totally (that is, the motor still runs
and drive’s LED displays ―P.OFF‖). It will start in the
starting mode defined in A1.00 after power on if it is
switched off totally (LED turns off).
A1.12
Anti-reverse
running
function
0
、
1
【
0
】
0: Disabled
1: Enabled
Note:
This function is effective in all control modes.
A1.13 Delay time of run reverse/
forward
0
~
3600s
【
0.0s
】
The delay time is the transition time at zero frequency
when the drive switching its running direction as shown
in Fig. 6-6 as t
1
.
Fig.6-6 Delay time from reverse running to forward
running or from forward running to reverse running
A1.14 Switch mode of run
reverse/forward
0
、
1
【
0
】
0:Switch when pass 0Hz
1:Switch when pass starting frequency
A1.15 Detecting frequency of
stop
0.00~150.00Hz
A1.16 Action voltage of
braking unit
650
~
750
【
700
】
A1.17 Dynamic braking
0
、
1
【
0
】
0
:
Dynamic braking is disabled
1
:
Dynamic braking is enabled
Note:
This parameter must be set correctly according to the
actual
conditions, otherwise the control performance may be
affected.
A1.18 Ratio of working time
of braking unit to drive’s total
working time
0.0
~
100.0
%【
80.0
%】
This function is effective for the drive with built-in
braking
resistor.
Note:
Resistance and power of the braking resistor must be
taken
into consideration when setting this parameters.
Time
t
1
Output
frequency