Table 1 Electrical Specifications
Parameter
Description
Input voltage
3M2280N: Single-phase 220V AC +/-15%
(50Hz)(187VAC~253VAC)
Phase
current(peak,
unit: A)
2.8, 3.2, 3.6, 4.0, 4.4, 4.8, 5.2, 5.6, 6, 6.4, 6.8, 7.2, 7.6 8.0
Micro step(unit:
pulse/rev)
400, 500, 600, 800, 1000, 1200, 1500, 2000, 3000, 4000, 5000,
6000, 10000, 20000
Input signal
Three control signal ports: PLS(CW)/DIR(CCW)/FRE; current
range: 6 ~16 mA
Control signal
input method
PLS+DIR; CW/CCW
Output signal
ERR, open collector output,
max current: 10 mA.
Protection
Over-voltage, under-voltage, short circuit, and overheat protection
Absorbing
circuit*
Need customize, used to absorb the energy feed back by the
motor
Table 2 Operating Environment
Cooling method
Forced air cooling
Environment
Operation
environment
Avoid the environment with great amount of
metallic powder, oil mist, or erosive gases.
Operation humidity
<85%, RH (non-condensing or water drops)
Operation
temperature
0
C ~ +40
C
Storage temperature
-20
C ~ +70
C
Weight (net)
1.5Kg
Dimensions
201mm×147mm×66mm
Ingress protection
IP20
3.2 Description of Wiring Terminal
Wiring terminals of the driver are divided into three types: control signal port, motor power
cable port, and power input port. Control signal port can receive differential signal,
single-ended common-cathode and common-anode signals, and can prevent the
interference of ambient environment on the driver with the built-in high-speed optocoupler.
The twisted pairs are recommended as signal lines for enhanced interference immunity in
environments with strong electromagnetic interference. The definitions of the driver ports
are detailed below:
Summary of Contents for 3M2280N
Page 1: ...Kinco N 3M2280N V1 2...
Page 2: ......
Page 4: ...2 3M2280N 310VDC 60 1 25...
Page 9: ...3M2280N 7 3 3 R0 24VDC 2K 12VDC 1K 6 16mA ERR OC 30V ERR...
Page 10: ...8 3 4 400KHz 1ms 10 1 5mm2 10mm...
Page 12: ...10 2 PLS DIR...
Page 13: ...3M2280N 11 3 6 50mm IP20...
Page 14: ...12 4 1 N Power Run Error Chop 0 5Hz 5Hz ERR 4 2 1 130 80 90 2 P 2 n 60 A B C...
Page 16: ......
Page 17: ...Kinco N Series Stepper Motor Driver 3M2280N User Manual Version V1 0...
Page 18: ......