Chapter 3    Product Parameters and Installation 

3.1 Product Parameters 

Please learn carefully the driver parameters before use. Make sure the power supply and 

operating environment conform to relevant requirements. 

Table 1    Electrical Specifications 

Parameter 

Description 

Input voltage 

3M2280N: Single-phase 220V AC +/-15% 
(50Hz)(187VAC~253VAC) 

Phase 
current(peak, 
unit: A) 

2.8, 3.2, 3.6, 4.0, 4.4, 4.8, 5.2, 5.6, 6, 6.4, 6.8, 7.2, 7.6 8.0 

Micro step(unit: 
pulse/rev) 

400, 500, 600, 800, 1000, 1200, 1500, 2000, 3000, 4000, 5000, 
6000, 10000, 20000 

Input signal 

Three control signal ports: PLS(CW)/DIR(CCW)/FRE; current 
range: 6 ~16 mA 

Control signal 
input method 

PLS+DIR; CW/CCW 

Output signal 

ERR, open collector output,

 

max current: 10 mA. 

Protection 

Over-voltage, under-voltage, short circuit, and overheat protection 

Absorbing 
circuit* 

Need customize, used to absorb the energy feed back by the 
motor 

Table 2    Operating Environment 

Cooling method

 

Forced air cooling

 

Environment

 

Operation 
environment

 

Avoid the environment with great amount of 
metallic powder, oil mist, or erosive gases.

 

Operation humidity

 

<85%, RH (non-condensing or water drops)

 

Operation 
temperature

 

0

C ~ +40

Storage temperature

 

-20

C ~ +70

Weight (net)

 

1.5Kg 

Dimensions

 

201mm×147mm×66mm 

Ingress protection

 

IP20 

3.2 Description of Wiring Terminal 

Wiring terminals of the driver are divided into three types: control signal port, motor power 
cable  port,  and  power  input  port.  Control  signal  port  can  receive  differential  signal, 
single-ended  common-cathode  and  common-anode  signals,  and  can  prevent  the 
interference of ambient environment on the driver with the built-in high-speed optocoupler. 
The twisted pairs are recommended as signal lines for enhanced interference immunity in 
environments  with  strong  electromagnetic  interference.  The  definitions  of  the  driver  ports 
are detailed below: 

Summary of Contents for 3M2280N

Page 1: ...Kinco N 3M2280N V1 2...

Page 2: ......

Page 3: ...3M2280N 1 2 3 2 1 3 2 2 3 2 3 3 2 4 3 2 5 4 2 6 4 5 3 1 5 3 2 5 3 3 7 3 4 8 3 5 9 3 6 11 12 4 1 12 4 2 12 N 3M2280N V1 2 2013 11 08 V1 0 2010 8 5 V1 1 2011 10 13 V1 2 2013 11 08...

Page 4: ...2 3M2280N 310VDC 60 1 25...

Page 5: ...3M2280N 3 2 1 3M2280N 1 1 1 1 2k 3 10mm 10 3 15mm 12 3 2 2 2 3 N DSP 2 4 3M2280N 187V 253V 220V ERR 1 5S...

Page 6: ...4 400KHZ 14 2 5 3M2280N DSP 1 5 25 60RPM PLS DIR CW CCW 3M2280N 395VDC 3M2280N 200VDC 75 2 6 KINCO 110 130...

Page 7: ...87VAC 253VAC 2 8 3 2 3 6 4 0 4 4 4 8 5 2 5 6 6 6 4 6 8 7 2 7 6 8 0 A 400 20000pulse rev 14 110 130 PLS CW DIR CCW FRE 6 16 mA PLS DIR CW CCW ERR 1 5s 50 2 85 RH 0 40 20 70 1 5Kg 201mm 147mm 66mm IP20...

Page 8: ...6 DIR CCW 1 25uS 400KHz FREE FREE ERR 30VDC 10mA ERR 4 U U V W V W NC R R 5 L 3M2280N 220V N PE...

Page 9: ...3M2280N 7 3 3 R0 24VDC 2K 12VDC 1K 6 16mA ERR OC 30V ERR...

Page 10: ...8 3 4 400KHz 1ms 10 1 5mm2 10mm...

Page 11: ...6000 10000 20000 SET1 SET2 S2 Current S2 0 1 2 3 4 5 6 7 Peak A 2 80 3 20 3 60 4 00 4 40 4 80 5 20 5 60 Rms A 1 98 2 26 2 55 2 83 3 11 3 39 3 68 3 96 S2 8 9 A B C D E F Peak A 6 00 6 40 6 80 7 20 7 60...

Page 12: ...10 2 PLS DIR...

Page 13: ...3M2280N 11 3 6 50mm IP20...

Page 14: ...12 4 1 N Power Run Error Chop 0 5Hz 5Hz ERR 4 2 1 130 80 90 2 P 2 n 60 A B C...

Page 15: ...Kinco Electric Shenzhen Ltd 6 518057 86 755 26585555 86 755 26616372 http www kinco cn Email sales kinco cn...

Page 16: ......

Page 17: ...Kinco N Series Stepper Motor Driver 3M2280N User Manual Version V1 0...

Page 18: ......

Page 19: ...of Wiring Terminal 6 3 3 Wiring Diagram 8 3 4 Time Sequence Diagram of Control Signal 10 3 5 DIP Switch Settings 11 3 6 Installation of the Driver 13 Chapter 4 FAQ 14 4 1 Indications of Driver Indica...

Page 20: ...related technical specifications and electric installation standards during installation The driver must be securely grounded with the cross section of the ground cable not less than 1 25 mm 2 Do not...

Page 21: ...1 pcs 2k resistors 3 pcs Length 10mm diameter 10 insulated terminals 3 pcs Length 15mm diameter 12 insulated terminals 3 pcs 2 2 Product Model Description 2 3 Product Features High performance low cos...

Page 22: ...s after the driver stops Half current function If the half current setting is effective After the motor stops rotation and locks tight the driver will reduce the phase current of the motor by a half i...

Page 23: ...river and the motor is wrong To clear the alarm reconnect the wires correctly 2 5 Scope of Application The drivers are applicable to various large and medium automation equipment and instruments inclu...

Page 24: ...customize used to absorb the energy feed back by the motor Table 2 Operating Environment Cooling method Forced air cooling Environment Operation environment Avoid the environment with great amount of...

Page 25: ...time in this mode shall not be less than 1 25uS The maximum input frequency of the pulse signal is 400 KHz DIR CCW FREE This signal is offline signal If the signal is at a high level the driver turns...

Page 26: ...User Manual 8 3 3 Wiring Diagram General Way Control Signal Wiring Diagram Twisted pair Way Control Signal Wiring Diagram...

Page 27: ...when the control signal is at 12VDC a 1K resistor can be connected The current at the input port of the driver must be within 6 16 mA otherwise it may cause damage to the equipment ERR signal is open...

Page 28: ...ground of the driver and equipment 3 Due to endurance of heavy current conductors with cross section no less than 1 5mm 2 are recommended for the motor cabling or even thicker ones as appropriate Mot...

Page 29: ...0 D when driver is power off then power on the driver the motor will run automatically PLS DIR E E Set S1 and S2 as the MODE settings as the left table when driver is power off then power on the driv...

Page 30: ...unction setting flow Drive power off Driver power on S1 E S2 E F C D Setting success Driver work in setting mode Reboot the driver RUN SLINK POWER GREEN ERR RED CHOP OFF Drive power off RUN SLINK POWE...

Page 31: ...ossible frequent overheat alarms For better heat dissipation two drivers shall be installed at a clearance of at least 50mm 1 With an ingress protection class of IP20 the driver shall be installed in...

Page 32: ...to phase error On Off On Blink quickly The motor power supply disconnects and the motor shaft releases Over current alarm On Off Blink quickly Off The motor power supply disconnects and the motor shaf...

Page 33: ...lt cause lower torque or out of step of the motor Therefore the maximum allowable surface temperature of a stepper motor depends on the demagnetization point of different magnetic materials In general...

Page 34: ...Shenzhen Ltd Address Building 1 No 6 Langshan 1st Rd Hi tech Park North Nanshan Shenzhen China 518057 Tel 86 755 2658555 Fax 86 755 26616372 http www kinco cn Email sales kinco cn To be the partner o...

Reviews: