Kimans HYDRASONIC S8 User Manual Download Page 2

Table of content 

 

1.

 

General Information

 ................................................................................................................................................... 3 

1.1 Application and Function

 ....................................................................................................................................... 3 

1.2

 

Contents of the package

 ........................................................................................................................................ 3 

1.3 Standards

 .................................................................................................................................................................. 3 

2.

 

Installation procedure

 ............................................................................................................................................... 4 

2.1 Installation of the meter

 ........................................................................................................................................ 4 

2.2 Installation angle

 ..................................................................................................................................................... 5 

2.3 Straight inlet

 ............................................................................................................................................................. 5 

2.4 Installation of temperature sensors

 ................................................................................................................... 6 

2.5 Temperature sensor pocket installation

 ............................................................................................................ 6 

3.

 

Installation procedure

 ............................................................................................................................................... 7 

4.

 

Lay length of BTU meter

 ........................................................................................................................................... 7 

5.

 

Display Menu

 ............................................................................................................................................................... 8 

5.1 Overall Menu Structure

 ........................................................................................................................................... 9 

5.2 Main Display

 ............................................................................................................................................................ 10 

5.3 Test Display

 ............................................................................................................................................................. 11 

5.4 Information Display

 ............................................................................................................................................... 12 

5.5 Error Display

 ........................................................................................................................................................... 13 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HYDRASONIC S8

Page 1: ...personnel Violation and removal of the manufacturer s seals is not allowed otherwise the warranties are void Welding on pipes near the meter is prohibited The device must be dismounted before welding...

Page 2: ...Installation of the meter 4 2 2 Installation angle 5 2 3 Straight inlet 5 2 4 Installation of temperature sensors 6 2 5 Temperature sensor pocket installation 6 3 Installation procedure 7 4 Lay length...

Page 3: ...irective on Electromagnetic Compatibility EMC Directive 2014 30 EU The identification plate of the instrument and the seals must not be removed or damaged otherwise the guarantee and the approved appl...

Page 4: ...ipe section Use gaskets between mating flanges on pipe and meter The meter can be installed in supply or return flow lines Please consult with factory on ordering to program the meter for either the s...

Page 5: ...eter will a straight inlet section be necessary We recommend following the guidelines in CEN CR 13582 Optimal position can be obtained by taking the below mentioned installation methods into considera...

Page 6: ...nsor in cold line o Red sensor in hot line The temperature sensors are to be installed symmetrically in the supply and return line The free temperature sensor can be installed in a pocket conforming t...

Page 7: ...Check the display for flow rate and temperature Seal the sensors Attach the seals to the calculator and temperature sensors Read the meter counts for energy volume and operating hours Ensure no errors...

Page 8: ...y At the start you are automatically in the main loop 1st level By pressing the push button longer than 4 seconds you change to the next display loop Keep the push button pressed until you reach the d...

Page 9: ...5 1 Overall Menu Structure...

Page 10: ...5 2 Main Display Short press 3 sec Long press 3 sec...

Page 11: ...5 3 Test Display...

Page 12: ...5 4 Information Display...

Page 13: ...5 5 Error Display...

Page 14: ...Kimans Inc www kimans com...

Reviews: