![Kimaldi BioMax2 Installation And Programming Manual Download Page 7](http://html1.mh-extra.com/html/kimaldi/biomax2/biomax2_installation-and-programming-manual_1967217007.webp)
BioMax2 / KBio2-Online
Installation and Programming Manual
Page
7 of 91
3. Technical Specifications
3.1. BioMax2
Size:
OEM board: 134 mm x 106 mm x 25 mm
Supply Voltage:
5 VDC. ± 10%
Maximum consumption
1
: 450 mA
Ethernet Interface:
10/100 Base-T
RS232 Interface:
Baud Rate between 9600 and 57600; n,8,1
5VDC Output:
Limited to 1 Amp by means of a retriggerable fuse. Maxi-
mum recommended current to external readers: 500 mA.
User interface:
2x20-character, backlit LCD Display; 4x4 numerical keypad,
buzzer on-board; output drivers for 2 LEDs (green and red)
and external buzzer.
Optical Barrier:
4-pin connector for LED and phototransistor
2
Relay contacts:
4 relay contacts, normally open, 24V / 1A
Digital inputs:
4 relay-type digital inputs. In open circuit (contact open) their
logic value will be 0. In contact with GND (contact closed),
logic value 1.
Clock&Data Inputs:
2 ports for Clock&Data readers, ABA-Track 2 encoding.
3.2. KBio2 Online
Size:
OEM board: 96 mm x 59 mm x 25 mm
Supply Voltage:
5 VDC. ± 10%
Maximum consumption
3
: 400 mA
Ethernet Interface:
10/100 Base-T
RS232 Interface:
Baud Rate between 9600 and 57600; n,8,1
5VDC Output:
Limited to 1 Amp by means of a retriggerable fuse. Maxi-
mum recommended current to external readers: 500 mA.
User Interface:
3-key pad with 3 LEDs and buzzer.
1. Consumption of the raw board, without peripheral devices connected to it.
2. The LED optical barrier has been discontinued on devices featuring FIM5360 or equivalent.
See
for further information
3. Consumption of the raw board, without peripheral devices connected to it.