![Kimaldi BioMax2 Installation And Programming Manual Download Page 61](http://html1.mh-extra.com/html/kimaldi/biomax2/biomax2_installation-and-programming-manual_1967217061.webp)
BioMax2 / KBio2-Online
Installation and Programming Manual
Page
61 of 91
9.6.15. Write Display, Backlit
Function: It shows the specified text via the display in 2 rows of 20 characters. The
timing of the backlighting and the buzzer assembled in the
BioMax2 / KBio2-Online
electronics are also specified.
9.6.16. Digital input status
Instruction
OP
0x14
NA
0x002A
ARG
Byte 1: Backlit time (from 0x00 to 0xFE tenths of a sec.)
Byte 2: Timing of the internal buzzer (from 0x00 to 0x19 tenths)
Bytes 3 to 22: Text of the first row
Bytes 23 to 42: Text of the second row
Response
OP
0x14
NA
0x0000
ARG
None
Instruction
OP
0x60
NA
0x0000
ARG
None
Response
OP
0x60
NA
0x0001
ARG
Bit 0: Status of DIN 0
Bit 1: Status of DIN 1
Bit 2: Status of DIN 2
Bit 3: Status of DIN 3