4 - Operation
It is very important that your battery chargers (solar charge controller, inverter/charger
or AC) can be set to settings appropriate for the HLX & CHLX. If it cannot, please
contact KiloVault Technical Support for guidance.
Also, some chargers just have settings for broad battery types like; flooded, gel, agm
or lithium. Before using these chargers on your battery, please contact KiloVault
technical support for guidance.
Note: If you cannot find a specific setting, remember to check the settings for
guidance. Also, please don’t hesitate to contact KiloVault technical support for help.
Voltages are per HLX in a single series string. Amperages are per total HLX strings in
parallel.
Adjust your settings as necessary until your system best fits your power use patterns
and needs.
4.1 - Inverter/Charger Settings
Setting
Values - Volts are per battery in a single
string, Amps are per string in parallel
1200 - Battery Capacity
1200 Wh. 100 Ah
1800 - Battery Capacity
1800 Wh. 150 Ah
3600 - Battery Capacity
3600 Wh, 300 Ah
1200 - Max Charge Current
80 A
1800/1600 Max Charge Current
150 A
Absorb End Amps
2 A
Absorb Time (some controllers do not allow a
selection under 6 minutes, please contact
KiloVault for additional information)
2 minutes or less
Absorb Voltage
14.1 V