Power on the scale: When the scale is off, press ON / OFF to turn it on; 

Power off the scale: When the scale is on, press ON / OFF to turn it off;

ZERO:  When the weight is stable and within the zero range (2% FS), press the ZERO key to set  

the new zero point. 

When the weight superceeds the zero range, press the ZERO key to tare the weight.

Symbol Definitions and Troubleshotting

The zero point is higher than the setting range.

0

The zero point is lower than the setting range.

AD

Signal to ADC is higher than the setting range.

AD

Signal to ADC is lower than the setting range.
The weight is higher than the upper limitation, or the  

display data is over limitation.
The weight is below the lower limitation.

EEP.E1  

The parameters CONFIG or CAL are not correctly set.

EEP.E2  

USER parameter is not correctly set.

CAP.- - - 

Capacity will be the next displaying content.

CAP.ER 

Capacity parameters are not correct.

OFF

Power OFF the indicator.

KPOS 1530, 851508, Page 7 of 9

Operation

Summary of Contents for KPOS 1530

Page 1: ...www kilotech com KPOS 1530 851508 Page 1 of 9 KPOS 1530 851508 POS Scale 15 kg Pole with display optional Version 1 0 Quick Start Manual Contents subject to change without notice...

Page 2: ...tech directly to properly repair your scale Do not dissemble the scale yourself This will void the warranty Contact your local distributor or Kilotech directly to properly repair your scale Do not ove...

Page 3: ...you can set it so it works when an item is placed on the platter Auto Power Off Power Adapter AC 7 9 V DC 500mA or USB Product Dimensions 355mm x 305mm x 88 5 mm 14 x 12 x 3 5 Platter Size 355mm x 30...

Page 4: ...and off With some scale models this key is also used to exit from the program menu On some scales the on off key is only present as the main switch located at the bottom of the scale and not as a but...

Page 5: ...rt USB Virtual RS232 RS232 Baud rate selectable 1200 2400 4800 9600 19200 38400 bps Data output format 8N1 7O1 7E1 Protocol Programmable Faceplate Illuminates when the scale is at zero and the gross w...

Page 6: ...ween AL ON WT ON or AL OFF AL ON backlight on WT ON backlight automatically is on during key operation or when changing weight and will auto off after 30 seconds have elapsed AL OFF backlight off Pres...

Page 7: ...point is higher than the setting range 0 The zero point is lower than the setting range AD Signal to ADC is higher than the setting range AD Signal to ADC is lower than the setting range The weight is...

Page 8: ...t measure c Reset some parameters in CONFG or USER Weight reading is below the Under load limit a Install platform on scale b Perform the zero calibration EEP E1 CONFIG or CAL parameters are not corre...

Page 9: ...851508 Page 9 of 9 Packing List No Item Qty 1 Scale 1 2 Quick Start Guide 1 3 AC Adapter 1 4 RS232 cable 1 5 USB cable 1 6 Post display option Optional VERSION DESCRIPTION DATE V1 0 Initial version 2...