![Kilews SKP-BC32HL Operation And Maintenance Manual Download Page 11](http://html1.mh-extra.com/html/kilews/skp-bc32hl/skp-bc32hl_operation-and-maintenance-manual_1966875011.webp)
SKP-BC32HL POWER
CONTROLLER (E)
CE
10
SW5: Auto-Learning Mode: The Counter counts screws number with the judging value OK & NG which is set up
by Ht and Lt, this Auto-Learning Mode is completely using Electric Screwdriver to fasten screws practically,
memorize the screwing time from beginning to complete fastening automatically, user can only change this
switch to ON, then system will ask how many screws (SC) of the fastening position been required? If need
auto response time setting (At) or if need to use the Slow-Start setting (Rc)?
SW6:
Arrangement form: The memory can save five units number, user can push switch ON, the system will
automatically arrange five units, easy for user to make arrangement at work.
※If using three units of data only and let three units in cycles. It can set up “00" in counting number on
U4, when SW6 switch ON, the system will automatically move in circle from U1~U3.