Dip Switch Functional Instruction
:
Instruction:
SW1
:
Selects ON, counts screws number forward as 1-----2-----3------4------5-------------------1….
Selects Off, count down the screws number as 5-----4-----3-----2------1---------------------5…
SW2: Sensing Switch, select ON means Counter needs external sensing switch, SKP-C32HL must be in
accordance with the sensing switch mode to determine if electric screwdriver will work. Select OFF means
unnecessary for external switch, count number don't have to consider external switch to determine if it
works.
SW3: The Count number Reset Mode, when counting screws number reach to the setting value, counter must be
reset to default value, if select ON which stands for manual reset, user must press "SELECT/CONFIRM"
Key on the panel back the setting count number, otherwise Electric Screwdriver is unable to start under no
confirming situation on the device. Select OFF makes system automatically to recover from the setting
count number.
SW4: Switching Mode: Select ON means the external SENSOR need to have two signals been sent to
SKP-C32HL which stands for the fastener on operational process need to go through the sensor on machine
table to identify the fastener has been removed from working table, and new fastener goes through another
SENSOR for confirming the new fastener that has reached the working table. Therefore two confirming
signals allow SKP-C32HL to start the Electric Screwdriver running. Select OFF means only need one
SENSOR to confirm the fastener that has been removed from this working table, this allows Electric
Screwdriver starts to work.
CONFIRM :
Code Instruction
Notations
A switch to confirm SENSOR.
SW2 (ON)+SW3(OFF)+SW4(OFF)
Output
Two switches to confirm SENSOR.
SW2 (ON)+SW3(OFF)+SW4(ON)
Output
Confirm on the panel .
SW3 (ON)+SW2(OFF)+SW4(OFF)
Panel CONFIRM
A switch SENSOR c manual CONFIRM on the Panel
SW2(ON)+SW3(ON)+SW4(OFF)
Panel
CONFIRM
SW2(ON)+SW3(ON)+SW4(ON) Two switch SENSOR c manual
CONFIRM Panel
SW2(ON)+SW3(ON)+SW4(ON)
Panel
CONFIRM
Information back to initial.
CLEAR
※
Making mistake in the middle of CONFIRM mode, when system detect abnormal, it will show Error
and buzzer sound. It must be reconfirmed SENSOR, push CONFIRM again.
SW Name
OFF
ON
1
Counting Mode
Count Down
Count Forward
2 Sensor
Switch
Stop
Work
3
Manual Confirm
Mold
Auto Zero
Start the Manual
Confirmation
4 Switching
Mode
Confirm by One
Switch
Confirm by Two
Switches
5
Auto Calculating
Mode
Stop Work
6
Units arrangement
Mode
Stop Work