Kilews SKP-BC32HL-100N Operation And Maintenance Manual Download Page 16

                                                                                       

                                                                                 

 

                                                                                                                                                                                           

 

15 

 

操作前請閱讀全部說明

 

   

(內附零件分解圖)

 

 

 

 

為了安全起見,在使用電動螺絲起子控制器前請詳閱電動螺絲起子控制器操作說明書,且務必

 

依照說明書指示操作,並注意所有的警示

 

 
 

 
 
 

1.

 

使用電動螺絲起子控制器說明書規定的電壓。

 

2.

 

使用電源時請確定電流回路與安全開關裝置,並同時將地線接妥。

 

3.

 

電動螺絲起子控制器勿置重物或堆積物品,且保持在適當的溫度與濕度狀態下工作。

 

4.

 

勿將電動螺絲起子控制器放在通風不良之室內,或暴露在塵埃和金屬屑中

 

5.

 

勿將電動螺絲起子控制器放在高溫潮濕的環境或易燃氣體的地方。

 

6.

 

勿將電動螺絲起子控制器裝置在高處,應放于安全、平穩、固定的位置,以防止掉落的危險。

 

7.

 

不可用電源線拉扯電動螺絲起子控制器,或將電源線從插座上猛拉開。

 

 
 

                                                     

     

 

    1

、此控制器請搭配整組的專用電動起子

SKD-BC

系列起子使用。

 

    2

、此控制器請配合

  KILEWS    SKD-BC

系列計數器電動起子使用,控制器若搭配非

  KILEWS

起子使用,

以及使用非

  KILEWS

原廠的零配件維修,而造成控制器發生故障或品質不良,導致一切保證失效本

廠恕不負責。

 

    3

、起子在進行中,若瞬間切換正反開關,機器將會啟動保護程式,起子將停止運轉。

 

4

、起子運轉中,禁止切換高低速開關。

 

    5

、電源關閉後

,

需待

LED

燈熄滅後才可插拔

DC

連接線。

 

 
 
 
 

1

 

操作前請詳細閱讀操作手冊,並且按照安全規範操作此電源供應器。

 

2

 

當插入或拔開起子連接線和電源線之插頭時,需抓緊電纜線之插頭部分。

 

3

 

請將此電源供應器固定,避免因拉扯而造成危險。

 

4

 

請勿靠近油

 

、化學物質或熱的物體,同時也注意不要讓電纜線在工作中刮磨到銳利的物品。

 

5

 

此型控制器,只能專門供

  KILEWS 

無碳刷電動起子計數器專用,勿將電動螺絲起子控制器使用於其

他機械。

 

6

 

假如控制器過熱,或負載使用電流超過保險絲最大額定電流時,快速型保險絲會自動熔斷,切斷電源,
持續跳脫或開關動作不正常時,請立即停止操作,並將電動螺絲起子控制器送回修理。

 

7

 

起子在進行中,若瞬間切換正反轉開關,機器將會啟動保護程式,起子會停止運轉。

 

8

 

請勿任意拆卸電動螺絲起子控制器嘗試自行修復。

 

9

 

不使用時將主要電源開關

 

”OFF”,並且拔掉電源插頭。

 

10

 

SKP

系列的輸出電壓調整至

Lo

的位置或小於

32V

的位置時,電動螺絲起子的扭力設定請低於刻

  4

位置以下使。

 

 

重要安全說明事項

 

 

 

 

 

 

 

 

 

Summary of Contents for SKP-BC32HL-100N

Page 1: ...OPERATION AND MAINTENANCE MANUAL SKP BC32HL 100N In AC 100 240V Out DC 24V 32V KILEWS INDUSTRIAL CO LTD http www kilews com Y2F077 1 004...

Page 2: ...n this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the...

Page 3: ...itable for outdoor use Use of cord suitable for outdoor use reduces the risk of electric shock 3 Personal Safety a Stay alert watch what you are doing and use common sense when operating a power tool...

Page 4: ...tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits ect in accordance with these instructions and in the manner intended fo...

Page 5: ...the protection program to force Electric Screwdriver stop 8 Please do not disassemble Electric Screwdriver casually and try to repair it by self 9 When Controller is not in use please turn the main p...

Page 6: ...F External Connection Input Confirm key Reset Key AffirmativeAffirmativeswitch recovery switch External Connection Output OK NG OK ALL Electric Screwdriver Speed Control HI LO Slow Start Size mm 200 1...

Page 7: ...Selection Confirm Key 4 BC 6Pin Connector 15 Buzzer hole 5 WORK Light 16 Power point 6 OK Light 17 POWER SWITCH 7 N G Light 18 I O Inserting Hole Instruction 8 24V Light 19 Functional Dip Switch Inst...

Page 8: ...t user set up number and unit during the process U1 No 1 setting number U2 No 2 setting number U3 No 3 setting number U4 No 4 setting number U5 No 5 setting number DOWN In system menu pressing the key...

Page 9: ...0mA CN4 OK ALL Output Output one signal after finishing the setting value of screw number count Auto start If operator needs to input voltage please do not exceed DC 12V 10mA CN5 COM CN6 GATE Input co...

Page 10: ...OR for confirming the new fastener that has reached the working table Therefore two confirming signals allow SKP BC32HL 100N to start the Electric Screwdriver running Select OFF means only need one SE...

Page 11: ...use the Slow Start setting Rc SW6 Arrangement form The memory can save five units number user can push switch ON the system will automatically arrange five units easy for user to make arrangement at w...

Page 12: ...PROCESS TO SET UP SYSTEM 1 Please connect the cord turn on the power switch until LED shows number 2 Please press SELECT key over three seconds till buzzer making sound the panel will show to push UP...

Page 13: ...er if Ht and Lt is closer it will request more precise If the user press the push button of the screwdriver after Ht and Lt setting it is N G Ht Lt mainly set up the period of time If stop is within t...

Page 14: ...use Electric Screwdriver Controller it should be grounded to avoid operator getting electrical shock This controller is equipped with 3 leading wires and 3 pins of grounding plug to fit for grounding...

Page 15: ...e center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your ne...

Page 16: ...15 1 2 3 4 5 6 7 1 SKD BC 2 KILEWS SKD BC KILEWS KILEWS 3 4 5 LED DC 1 2 3 4 5 KILEWS 6 7 8 9 OFF 10 SKP Lo 32V 4...

Page 17: ...FF 1 Sensor 0 1 9 9 seconds 35 85 L0 L9 Rated speed 0 01 9 90 seconds 0 1 9 9 seconds On Off FF EF with LED and buzzer ON OFF OK NG OK ALL HI LO mm 200 130 100 Kg SKD BC512LF SKD BC512PF SKD BC519L SK...

Page 18: ...17 NO NO 1 LED 12 2 HI LO 13 3 14 4 BC6PIN 15 5 16 6 OK 17 7 N G 18 8 24V 19 I O 9 32V 20 10 11 16 17 18 19 2 3 4 5 8 11 9 10 6 7 13 12 1 14 20 15...

Page 19: ...18 POWER 8 7 LED WORK CLEAR SELECT 7 SL SC At RC SP Ht Lt LL CONFIRM DIP SW3 ON CONFIRM UP UP U1 1 U4 4 U2 2 U5 5 U3 3 DOWN UP U1 1 U4 4 U2 2 U5 5 U3 3 UP DOWN S RESET LC Un HL...

Page 20: ...12V 10mA CN3 NG DC 12V 10mA CN4 OK ALL DC 12V 10mA At CN5 COM CN6 GATE OFF ON COM CN5 CN7 CLR CLEAR COM CN5 CN8 9 OK CN8 9 60V 400mA CN10 11 NG CN10 11 60V 400mA CN12 13 OK ALL CN12 13 60V 400mA CN14...

Page 21: ...ELECT CONFIRM OFF SW4 ON SENSOR SKP BC32HL 100 SENSOR SENSOR SKP BC32HL 100 OFF SENSOR CONFIRM SENSOR SW2 ON SW3 OFF SW4 OFF Output SENSOR SW2 ON SW3 OFF SW4 ON SENSOR Er CONFIRM Er Output CONFIRM SW3...

Page 22: ...ON CONFIRM SW2 ON SW3 ON SW4 OFF Output CONFIRM SENSOR CONFIRM SW2 ON SW3 ON SW4 ON Output CONFIRM CLEAR CONFIRM SENSOR CONFIRM SW5 OK N G Ht Lt ON SL SC At Rc SP SW6 5 ON 5 SW7 ON OFF 3 3 U4 SC 00 SW...

Page 23: ...ECT UP DOWN 9 9 At 5 SELECT UP DOWN 9 9 Rc 6 SELECT UP DOWN L9 SP 7 SELECT UP DOWN 9 9 Ht 8 SELECT POWER UP DOWN 9 90 Lt 02 0 02 SL 01 05 SC 01 99 05 At 0 1 9 9 AUTO T 1 0 RC 0 1 9 9 SP L0 L9 35 85 L0...

Page 24: ...R UP DOWN 9 90 LL 02 0 02 10 SELECT Ht Lt Ht Lt LL Start Lt 0 02 Ht 2 0 LL 1 0 OK N G N G OK Lt Ht N G Lt Lt Ht Ht Lt N G Ht Lt OK Lt Ht N G Ht Lt Lt 0 00 SELECT STOP STAR T OK N G Lt 0 5 s Ht 2 0 s L...

Page 25: ...24 1 SW5 ON SW5 ON 2 ON LED CHECK 3 LED 0 0 LED DIP SW5 OFF Lt Ht 4 DIP SW5 OFF SELECT 7 SL SELECT SC SELECT At SELECT Rc SELECT SP SELECT Ht SELECT Lt SELECT LL SELECT CHECK ESD ON OFF...

Page 26: ...O DES BY CHKD BY APPD BY TITLE CUSTOMER DWG NAME DWG NO MATERIAL DATE DATE DATE UNIT SHRINK SCALE SHT NO OF SHTS 2 3 4 5 16 20 21 6 12 15 17 11 7 8 10 9 18 22 25 25 26 23 19 24 26 25 30 31 28 29 30 33...

Page 27: ...8 CONNECT 3P 1 6 EG50111 hypothesis PCB 1 28 X10068 BOLT 1 7 P11402 11 Hi Lo Switch ASS Y Hi Lo 1 29 X10067 WASHER 1 8 P11404 2 Key Switch ASS Y 1 30 CH20302 WASHER M4 6 9 P11404 1 Key 1 31 CH20401 BO...