background image

                                                                                       

                                                                                 

 

                                                                                                                                                                                           

 

12 

 

 

9

To press SELECT, the screen will show                  ,                  push POWER key                , adjust decimals   

00. push UP/DOWN to increase or decrease number, the maximum can set up 9.90. 
LL: No times confirmed within set-

up time after fastening. “02.” means 0.02 

 
10

To press SELECT                    to confirm. 

 
 

Data Chart

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

Execute under general pre-set program

 

 

 

 

 

 

 

Start     

 

 

 

 

If the screwdriver stop time is in dotted line. 

it is normal fastening. “OK”will be shown. 

 

If the screwdriver stop time is before Lt or over Htstop is before Ht or over Lt, 

it is “N.G.”. 

 

User can freely adjust Ht. However, if Ht and Lt is closer, it will request more precise. 

 

If the user press the push button of the screwdriver after Ht and Lt setting, it is 

“N.G”. 

 

 
 

Ht/Lt mainly set up the period of time. If stop is within the set period, it means OK. In 
contras, it will be (NG), as stop before Lt or after Ht. and should reconfirm whether wrong 
screws is taken. More precise requested means more correct Ht/Lt set-up should be. The 
LT accepts 0.00, but it can be increased or decreased in SELECT.   

 

 

 

 

 

 

 

 

STAR

STOP 

  Lt   

0.5 s 

          Ht 

2.0 s 

If screwdriver stops before Lt.

 

If screwdriver has no stop after Ht. 

N.G 

N.G 

OK 

It is “OK” as 

screwdriver stops 

between Lt and Ht. 

Screws stuck or wrong screws 

Screws stripped or wrong screws 

Lt=0.02 

Ht=2.0 

LL=1.0 

OK 

N.G 

N.G 

Summary of Contents for SKP-BC32HL-100N

Page 1: ...OPERATION AND MAINTENANCE MANUAL SKP BC32HL 100N In AC 100 240V Out DC 24V 32V KILEWS INDUSTRIAL CO LTD http www kilews com Y2F077 1 004...

Page 2: ...n this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the...

Page 3: ...itable for outdoor use Use of cord suitable for outdoor use reduces the risk of electric shock 3 Personal Safety a Stay alert watch what you are doing and use common sense when operating a power tool...

Page 4: ...tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits ect in accordance with these instructions and in the manner intended fo...

Page 5: ...the protection program to force Electric Screwdriver stop 8 Please do not disassemble Electric Screwdriver casually and try to repair it by self 9 When Controller is not in use please turn the main p...

Page 6: ...F External Connection Input Confirm key Reset Key AffirmativeAffirmativeswitch recovery switch External Connection Output OK NG OK ALL Electric Screwdriver Speed Control HI LO Slow Start Size mm 200 1...

Page 7: ...Selection Confirm Key 4 BC 6Pin Connector 15 Buzzer hole 5 WORK Light 16 Power point 6 OK Light 17 POWER SWITCH 7 N G Light 18 I O Inserting Hole Instruction 8 24V Light 19 Functional Dip Switch Inst...

Page 8: ...t user set up number and unit during the process U1 No 1 setting number U2 No 2 setting number U3 No 3 setting number U4 No 4 setting number U5 No 5 setting number DOWN In system menu pressing the key...

Page 9: ...0mA CN4 OK ALL Output Output one signal after finishing the setting value of screw number count Auto start If operator needs to input voltage please do not exceed DC 12V 10mA CN5 COM CN6 GATE Input co...

Page 10: ...OR for confirming the new fastener that has reached the working table Therefore two confirming signals allow SKP BC32HL 100N to start the Electric Screwdriver running Select OFF means only need one SE...

Page 11: ...use the Slow Start setting Rc SW6 Arrangement form The memory can save five units number user can push switch ON the system will automatically arrange five units easy for user to make arrangement at w...

Page 12: ...PROCESS TO SET UP SYSTEM 1 Please connect the cord turn on the power switch until LED shows number 2 Please press SELECT key over three seconds till buzzer making sound the panel will show to push UP...

Page 13: ...er if Ht and Lt is closer it will request more precise If the user press the push button of the screwdriver after Ht and Lt setting it is N G Ht Lt mainly set up the period of time If stop is within t...

Page 14: ...use Electric Screwdriver Controller it should be grounded to avoid operator getting electrical shock This controller is equipped with 3 leading wires and 3 pins of grounding plug to fit for grounding...

Page 15: ...e center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your ne...

Page 16: ...15 1 2 3 4 5 6 7 1 SKD BC 2 KILEWS SKD BC KILEWS KILEWS 3 4 5 LED DC 1 2 3 4 5 KILEWS 6 7 8 9 OFF 10 SKP Lo 32V 4...

Page 17: ...FF 1 Sensor 0 1 9 9 seconds 35 85 L0 L9 Rated speed 0 01 9 90 seconds 0 1 9 9 seconds On Off FF EF with LED and buzzer ON OFF OK NG OK ALL HI LO mm 200 130 100 Kg SKD BC512LF SKD BC512PF SKD BC519L SK...

Page 18: ...17 NO NO 1 LED 12 2 HI LO 13 3 14 4 BC6PIN 15 5 16 6 OK 17 7 N G 18 8 24V 19 I O 9 32V 20 10 11 16 17 18 19 2 3 4 5 8 11 9 10 6 7 13 12 1 14 20 15...

Page 19: ...18 POWER 8 7 LED WORK CLEAR SELECT 7 SL SC At RC SP Ht Lt LL CONFIRM DIP SW3 ON CONFIRM UP UP U1 1 U4 4 U2 2 U5 5 U3 3 DOWN UP U1 1 U4 4 U2 2 U5 5 U3 3 UP DOWN S RESET LC Un HL...

Page 20: ...12V 10mA CN3 NG DC 12V 10mA CN4 OK ALL DC 12V 10mA At CN5 COM CN6 GATE OFF ON COM CN5 CN7 CLR CLEAR COM CN5 CN8 9 OK CN8 9 60V 400mA CN10 11 NG CN10 11 60V 400mA CN12 13 OK ALL CN12 13 60V 400mA CN14...

Page 21: ...ELECT CONFIRM OFF SW4 ON SENSOR SKP BC32HL 100 SENSOR SENSOR SKP BC32HL 100 OFF SENSOR CONFIRM SENSOR SW2 ON SW3 OFF SW4 OFF Output SENSOR SW2 ON SW3 OFF SW4 ON SENSOR Er CONFIRM Er Output CONFIRM SW3...

Page 22: ...ON CONFIRM SW2 ON SW3 ON SW4 OFF Output CONFIRM SENSOR CONFIRM SW2 ON SW3 ON SW4 ON Output CONFIRM CLEAR CONFIRM SENSOR CONFIRM SW5 OK N G Ht Lt ON SL SC At Rc SP SW6 5 ON 5 SW7 ON OFF 3 3 U4 SC 00 SW...

Page 23: ...ECT UP DOWN 9 9 At 5 SELECT UP DOWN 9 9 Rc 6 SELECT UP DOWN L9 SP 7 SELECT UP DOWN 9 9 Ht 8 SELECT POWER UP DOWN 9 90 Lt 02 0 02 SL 01 05 SC 01 99 05 At 0 1 9 9 AUTO T 1 0 RC 0 1 9 9 SP L0 L9 35 85 L0...

Page 24: ...R UP DOWN 9 90 LL 02 0 02 10 SELECT Ht Lt Ht Lt LL Start Lt 0 02 Ht 2 0 LL 1 0 OK N G N G OK Lt Ht N G Lt Lt Ht Ht Lt N G Ht Lt OK Lt Ht N G Ht Lt Lt 0 00 SELECT STOP STAR T OK N G Lt 0 5 s Ht 2 0 s L...

Page 25: ...24 1 SW5 ON SW5 ON 2 ON LED CHECK 3 LED 0 0 LED DIP SW5 OFF Lt Ht 4 DIP SW5 OFF SELECT 7 SL SELECT SC SELECT At SELECT Rc SELECT SP SELECT Ht SELECT Lt SELECT LL SELECT CHECK ESD ON OFF...

Page 26: ...O DES BY CHKD BY APPD BY TITLE CUSTOMER DWG NAME DWG NO MATERIAL DATE DATE DATE UNIT SHRINK SCALE SHT NO OF SHTS 2 3 4 5 16 20 21 6 12 15 17 11 7 8 10 9 18 22 25 25 26 23 19 24 26 25 30 31 28 29 30 33...

Page 27: ...8 CONNECT 3P 1 6 EG50111 hypothesis PCB 1 28 X10068 BOLT 1 7 P11402 11 Hi Lo Switch ASS Y Hi Lo 1 29 X10067 WASHER 1 8 P11404 2 Key Switch ASS Y 1 30 CH20302 WASHER M4 6 9 P11404 1 Key 1 31 CH20401 BO...