5
1) Whenever c
hanging a bit, make certain the Forward / Reverse Switch is in the “ OFF “ position and tool is unplugged.
2) Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or other similar chemicals to
come in contact with the screwdriver housing as damage will result.
3) Do not drop or abuse the screwdriver.
4) Do not adjust the torque setting higher than 8 on the torque scale.
5) Operation frequency: The original setting of the frequency is 1 sec on / 3 sec off. The number of screw fastened is
about 15 pcs. Over frequently using makes the motor overheated and damage to screwdriver.
Enough heat-dissipation is good for screwdriver.
6) Do not use this screwdriver for tightening wood screws. This is “ Metal Assembly ScrewDriver ”
7) Do not operate the Forward / Reverse Switch the motor is running.
8) Whenever a tool is not being used, move the Forw
ard / Reverse Switch to the “OFF” position and unplug the
screwdriver.
9) Don't touch For&Rew Switch during operating for keeping system from wrong judgement.
10)
Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference
Use Anti-interference lines.
● Do not drop or abuse the tool.
● Whenever a tool is not being used, position the Power Switch to the “OFF” position and unplug the power cord.
Slow speed (rpm) operation frequency
Slow speed (rpm)
operation frequency
Slow speed (rpm)
operation frequency
900
1.0 ON 3.0 OFF
600
1.0 ON 3.0 OFF
300
2.0 ON 5.0 OFF
850
1.0 ON 3.0 OFF
550
2.0 ON 5.0 OFF
250
2.0 ON 5.0 OFF
800
1.0 ON 3.0 OFF
500
2.0 ON 5.0 OFF
200
2.0 ON 5.0 OFF
750
1.0 ON 3.0 OFF
450
2.0 ON 5.0 OFF
150
2.0 ON 5.0 OFF
700
1.0 ON 3.0 OFF
400
2.0 ON 5.0 OFF
100
2.0 ON 5.0 OFF
650
1.0 ON 3.0 OFF
350
2.0 ON 5.0 OFF
Operations Cautions
CAUTION
Slow speed Duty Cycle Conversion (for reference)
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650
,
650/1000%=65%
ON= 1*1.65= 1.65
,
OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF
This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off.