background image

Kieback&Peter GmbH & Co. KG
Tempelhofer Weg 50, 12347 Berlin/Germany
Telefon: +49 30 60095-0, Telefax: +49 30 60095-164
www.kieback-peter.de, [email protected]

Datasheet 1.10-60.010-01-EN

RBW301-C, RBW302-C, RBW304-C, RBW305-C

Issue 2017-07-20

A

Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications -

 

Reservado el derecho a modificación

 

- Wijzigingen

voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения

 

-

A változtatások jogát fenntartjuk -

 

؍⮉ᵚ㓿䙊⸕㘼᭩ࣘⲴᵳ࣋

Product Description

RBW301-C, RBW302-C, RBW304-C, RBW305-C 
Room Control Module

Application

Room control module with display, room temperature 
sensor and manual setting of the room temperature 
setpoint for the following room controllers and 
automation systems: 

RCN150-L, RCN151-L, RCN152-L, RCN155-L

RCC200-L or RCN200-L

RCN420-B

DDC4000, DDC420

Different variants with a graded range of functions are 
available: Set room temperature, manual and automatic 
fan control, presence button (present/absent).

Content

Page

Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3

Technical Data.....................................................................................................................................................3
Accessories (not included in delivery) .................................................................................................................3
Compatibility ........................................................................................................................................................4
Dimensions ..........................................................................................................................................................4
Connection...........................................................................................................................................................5

Mounting ................................................................................................................................................................6
Function/Operation ................................................................................................................................................8

Setting the room temperature ..............................................................................................................................9
Energy saving function (RBW304-x, RBW305-x) ................................................................................................9
Schedule..............................................................................................................................................................9

CAN Address Setting...........................................................................................................................................10
Installation............................................................................................................................................................11
Notes for service technicians...............................................................................................................................11

Summary of Contents for RBW301-C

Page 1: ...le Application Room control module with display room temperature sensor and manual setting of the room temperature setpoint for the following room controllers and automation systems RCN150 L RCN151 L...

Page 2: ...ystem installer or operator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are pers...

Page 3: ...splay Feedback presence fan status heating cooling window contact weekly schedule time date project specific messages service level Knob with confirmation key for setting the temperature time and week...

Page 4: ...CN200 L or RCN420 B room controllers up to four room control modules depending on the application DDC420 automation station up to 3 room control modules DDC4200 L DDC4200 DDC4002 DDC4400 DDC4200e DDC4...

Page 5: ...20 RBW20X C RBW30X C RCN420 B 21 20 19 22 0V 12VDC CAN CAN 0V DC 12V DC 19 18 17 20 52 53 50 51 9 8 7 16 15 10 3 2 1 6 5 4 57 60 59 58 GND K1 P1 GND K3 GND P3 GND K2 P2 13 12 11 14 GND K4 GND P4 GND P...

Page 6: ...removal may only be carried out by qualified technicians when the power is switched off Choose an installation location that is subject to the air flow of the room to ensure that the room controller...

Page 7: ...RBW302 C RBW304 C RBW305 C Product Description Issue 2017 07 20 Mounting on standard flush mounted box 4 wire on terminal Direct wall mounting with Z146 adapter frame 4 wire on terminal 1 2 3 4 5 6 Z...

Page 8: ...witch on time for the utilization schedule timer and Absent No settings can be made Additionally Display of the switch off time for the utilization schedule timer and Fan in automatic operating mode T...

Page 9: ...ng days SA SU weekend MO SU week as well as MO TU WE TH FR SA SU for the individual days Press and hold the knob for three seconds The schedules are displayed Rotate the knob Select the schedule Press...

Page 10: ...the TIME function Press the knob Confirm selection Set the time Set the hour Confirm the setting Set the minute Confirm the setting Set the date Set the year Confirm the setting Set the month Confirm...

Page 11: ...trol modules that lights up green Notes for service technicians Additional indicators on the display Querying the service settings Press and hold the knob for three seconds Rotate the knob Select the...

Page 12: ...A Page 12 12 Product Description RBW301 C RBW302 C RBW304 C RBW305 C Datasheet 1 10 60 010 01 EN Issue 2017 07 20...