TEN YEAR LIMITED WARRANTY

KIDDE warrants to the original purchaser that the enclosed smoke alarm (but not the
battery) will be free from defects in material and workmanship or design under normal
use and service for a period of ten years from the date of purchase.  The obligation of
KIDDE under this warranty is limited to repairing or replacing the smoke alarm or any
part which we find to be defective in material, workmanship or design, free of charge
to the customer, upon sending the smoke alarm with proof of date of purchase,
postage and return postage prepaid, to Warranty Service Department, KIDDE, 1016
Corporate Park Dr., Mebane, NC 27302.

This warranty shall not apply to the smoke alarm if it has been damaged, modified,
abused or altered after the date of purchase or if it fails to operate due to improper
maintenance or inadequate DC electrical power.

THE LIABILITY OF KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS
ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS
LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT
OF SMOKE ALARM AND, IN NO CASE, SHALL KIDDE OR ANY OF ITS PARENT OR SUB-
SIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES
RESULTING FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS
CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.

Since some states do not allow limitations on the duration of an implied warranty or
do not allow the exclusion or limitation of incidental or consequential damages, the
above limitations or exclusions may not apply to you.  While this warranty gives you
specific legal rights, you may also have other rights which vary from state to state.

Also, KIDDE makes no warranty, express or implied, written or oral, including that of
merchantability or fitness for any particular purpose, with respect to the battery.

The above warranty may not be altered except in writing signed by both parties hereto.

U.S. Patent No. 6,160,487; 6,753,786 and other Patents Pending

©Copyright Walter Kidde Portable Equipment 2005. All Rights Reserved.

QUESTIONS OR FOR MORE INFORMATION

Call our Consumer Hotline at 

1-800-880-6788

or contact 

us at our website at 

www.kidde.com

Kidde, 1016 Corporate Park Drive, Mebane, NC 27302

0919-7201-02.qxd  1969.12.31  4:15 PM  Page 19

Summary of Contents for RF-SM-DC

Page 1: ...o that when one unit sounds it will trigger all other units to sound thereby giving a family more time to escape Kidde estimates that nearly 100 million U S homes either do not have interconnected smo...

Page 2: ...sooner than ionization alarms Home fires develop in different ways and are often unpredictable For maximum protection Kidde recommends that both Ionization and Photoelectric alarms be installed WARNIN...

Page 3: ...of the ceiling places it clos est to all points in the room Ceiling mounting is preferred in ordinary resi dential construction For mobile home installation select locations carefully to avoid thermal...

Page 4: ...larm at a minimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see figure 1 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling a...

Page 5: ...an RF signal Electronic noise may cause nuisance alarms Near large metal surfaces and bundles of wire Smoke alarms are not to be used with detector guards unless the combination alarm and guard have...

Page 6: ...alarms 8 Read the user s guide and keep it in a safe place for future reference If your Wireless smoke alarms enter alarm mode first check to see if there is a fire If a fire does not exist and the t...

Page 7: ...nstalled Removal of any or all batteries will render the alarm inoperative CAUTION Alarm will not engage to bracket unless all three batter ies are installed Removal of any or all batteries will rende...

Page 8: ...sing the Test Button All interconnected alarms should respond CAUTION Due to the loudness of the alarm always stand an arm s length away from the unit when testing Tamper Resist Features This alarm ha...

Page 9: ...ir has been cleared of the condition causing the alarm Pushing the test button on the alarm will end the HUSH period Remote HUSH Control Press the button on any Kidde Wireless device to acti vate the...

Page 10: ...t reset button is pressed thus resetting the alarm HUSH MODE CONDITION The LED will flash every 2 seconds while the alarm is in HUSH mode TESTING TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION When...

Page 11: ...mely useful in a kitchen area or other areas prone to nui sance alarms For more information refer to Section 4 OPERATION AND TEST ING If the alarm does sound check for fires first If a fire is discove...

Page 12: ...t saving time CAUTION YOUR SMOKE ALARM IS SEALED AND THE COVER IS NOT REMOVABLE CAUTION Alarm will not engage to bracket unless all three batter ies are installed Removal of any or all batteries will...

Page 13: ...re devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing limitations Ionization sensing alarms may detect invisible fire particles associated with f...

Page 14: ...you all can meet if a fire occurs Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including...

Page 15: ...se a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products The radioactive element is safely contained in the chamber and r...

Page 16: ...ations occasionally experience conditions that can result in improper operation This equipment should be installed in accordance with the National Fire Protection Association s Standard 72 NFPA Batter...

Page 17: ...ame ID Devices may not have power Button not pressed long enough There may be too much interference between units Unit is set to the same ID as a system nearby Unit is located in area prone to cause f...

Page 18: ...the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The ter...

Page 19: ...CEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF ITS PARENT OR SUB SIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREAC...