background image

use an open flame to test your alarm, you could damage the
alarm or ignite combustible materials and start a structure fire.

Alarm Memory:

This smoke alarm is equipped with an alarm 
memory feature which produces a rapid 
chirping sound when the test button is 
pushed. This sound indicates that the alarm 
has been activated since it was last tested. 
Releasing the test button clears the memory. 
If the alarm memory sound is heard, release 
the test button and press the test button 
again to enter the normal test mode.

TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. Erratic
or low sound coming from your alarm may indicate a defective
alarm, and it should be returned for service (see section 12).

NOTE:  WEEKLY TESTING IS REQUIRED.

5. NUISANCE ALARMS

Smoke alarms are designed to minimize nuisance alarms.
Cigarette smoke will not normally set off the alarm, unless the
smoke is blown directly into the alarm.  Combustion particles from
cooking may set off the alarm if the alarm is located close to the
cooking area.  Large quantities of combustible particles are gener-
ated from spills or when broiling.  Using the fan on a range hood
which vents to the outside (non-recirculating type) will also help
remove these combustible products from the kitchen.

If the alarm does sound, check for fires first.  If a fire is discovered,
get out and call the fire department.  If no fire is present, check to
see if one of the reasons listed in section 2 may have caused the
alarm.

The Model PI 9000 has a “HUSH” control that is extremely useful
in a kitchen area or other areas prone to nuisance alarms. For
more information refer to section 4, OPERATION AND TESTING.

6. MAINTENANCE

BATTERY REPLACEMENT

If tamper resist feature has been used, refer to TAMPER RESIST
FEATURE in section 3 for removal instructions.

 

Summary of Contents for PI9000 UK

Page 1: ...is smoke alarm It is an important part of your family s home safety plan You can trust this prod uct to provide the highest quality safety protection We know you expect nothing less when the lives of...

Page 2: ...S OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE ALARMS 6 MAINTENANCE 7 LIMITATIONS OF SMOKE ALARMS 8 GOOD...

Page 3: ...the room Ceiling mounting is preferred in ordinary residential construc tion For mobile home installation select locations carefully to avoid thermal barriers that may form at the ceiling For more de...

Page 4: ...utside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling In such units install the smoke...

Page 5: ...areas Kitchens Normal cooking may cause nuisance alarms If a kitchen alarm is desired it should have an alarm silence feature or be a photoelectric type Near fluorescent lights Electronic noise may c...

Page 6: ...e screws and anchors provided to secure the mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper insta...

Page 7: ...sist tab is engaged press down on the tamper resist tab and rotate the alarm off of the trim ring see figure 6 After installation test your alarm by depressing and holding down the test button for at...

Page 8: ...he red LED will flash every 30 40 seconds to indicate that the smoke alarm is operating properly Alarm Condition When the alarm senses products of combustion and goes into alarm the red LED will flash...

Page 9: ...alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if the alarm is located close to t...

Page 10: ...ANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL...

Page 11: ...different ways and are often unpredictable For maximum protection Kidde recom mends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the speci...

Page 12: ...e extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all s...

Page 13: ...is manufactured and dis tributed under license from the U S Nuclear Regulatory Commission 10 NFPA REQUIRED PROTECTION The National Fire Protection Association s Standard 72 provides the following inf...

Page 14: ...LOCAL FIRE DEPARTMENT AND INSURANCE COM PANY OF YOUR SMOKE ALARM INSTALLATION 11 CAUTION AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL FOR UNITED STATES ONLY Early warning fire detection is best a...

Page 15: ...dequate AC or DC electrical power This guarantee does not cover batteries This guarantee applies only to individuals situated in the United Kingdom This guarantee is nontransferrable MAKING A CLAIM UN...