background image

1. Remove the mounting plate from the back of the alarm by hold-

ing the mounting plate and twisting the alarm in the direction
indicated by the “OFF” arrow on the alarm cover.

2. To insure aesthetic alignment of the alarm with the hallway or

wall, the “A” line on the mounting plate should be parallel with
the hallway when ceiling mounting or horizontal when wall
mounting.

3. After selecting the proper smoke alarm location as described in

section 1, attach the mounting plate to the ceiling as shown in
figure 4.  For wall mounting see figure 4.  Place mounting plate
on the wall. Be sure the “A” line is horizontal. Use the screws
and anchors provided to secure the mounting plate (use 3/16”
drill bit for anchor holes).  

4. Battery installation instructions are provided on the inside of the

battery door. 
To ensure proper installation of the smoke alarm battery, follow
the instructions.

5. When installing the battery, press the battery reminder finger

down into the battery compartment and install the battery (see
figure 5).

CAUTION! IF THE BATTERY REMINDER FINGER IS NOT HELD
DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY,
THE BATTERY DOOR WILL NOT CLOSE AND THE UNIT WILL
NOT ATTACH TO THE MOUNTING BRACKET.

6. Install the alarm on the trim ring and rotate the alarm in the

direction of the "ON" arrow on the cover until the alarm ratch-
ets into place (this ratcheting function allows for aesthetic align-
ment).

FIGURE 5

Battery
Reminder
Finger

Summary of Contents for PI9000 UK

Page 1: ...is smoke alarm It is an important part of your family s home safety plan You can trust this prod uct to provide the highest quality safety protection We know you expect nothing less when the lives of...

Page 2: ...S OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE ALARMS 6 MAINTENANCE 7 LIMITATIONS OF SMOKE ALARMS 8 GOOD...

Page 3: ...the room Ceiling mounting is preferred in ordinary residential construc tion For mobile home installation select locations carefully to avoid thermal barriers that may form at the ceiling For more de...

Page 4: ...utside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling In such units install the smoke...

Page 5: ...areas Kitchens Normal cooking may cause nuisance alarms If a kitchen alarm is desired it should have an alarm silence feature or be a photoelectric type Near fluorescent lights Electronic noise may c...

Page 6: ...e screws and anchors provided to secure the mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper insta...

Page 7: ...sist tab is engaged press down on the tamper resist tab and rotate the alarm off of the trim ring see figure 6 After installation test your alarm by depressing and holding down the test button for at...

Page 8: ...he red LED will flash every 30 40 seconds to indicate that the smoke alarm is operating properly Alarm Condition When the alarm senses products of combustion and goes into alarm the red LED will flash...

Page 9: ...alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if the alarm is located close to t...

Page 10: ...ANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL...

Page 11: ...different ways and are often unpredictable For maximum protection Kidde recom mends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the speci...

Page 12: ...e extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all s...

Page 13: ...is manufactured and dis tributed under license from the U S Nuclear Regulatory Commission 10 NFPA REQUIRED PROTECTION The National Fire Protection Association s Standard 72 provides the following inf...

Page 14: ...LOCAL FIRE DEPARTMENT AND INSURANCE COM PANY OF YOUR SMOKE ALARM INSTALLATION 11 CAUTION AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL FOR UNITED STATES ONLY Early warning fire detection is best a...

Page 15: ...dequate AC or DC electrical power This guarantee does not cover batteries This guarantee applies only to individuals situated in the United Kingdom This guarantee is nontransferrable MAKING A CLAIM UN...

Reviews: