recommended that the householder consider the use of additional
smoke alarms for those areas for increased protection.  The addi-
tional areas include the basement, bedrooms, dining room, fur-
nace room, utility room, and hallways not protected by the
required smoke alarms.  The installation of the smoke alarms in
the kitchen, attic (finished or unfinished), or garage is normally not
recommended, as these locations occasionally experience condi-
tions that can result in improper operation.

This equipment should be installed in accordance with the
National Fire Protection Association’s Standard 72 (NFPA,
Batterymarch Park, Quincy, MA 02269).

NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COM-
PANY OF YOUR SMOKE ALARM INSTALLATION.

11. CAUTION (AS REQUIRED BY THE CALIFORNIA
STATE FIRE MARSHAL FOR UNITED STATES ONLY)

“Early warning fire detection is best achieved by the installation of
fire detection  equipment in all rooms and areas of the household
as follows. A smoke alarm installed in each separate sleeping area
(in the vicinity of, but outside of the bedrooms), and heat or
smoke alarms in the living rooms, dining rooms, bedrooms,
kitchens,  hallways, attics, furnace rooms, closets, utility and stor-
age rooms, basements and attached garages.”

12. SERVICE AND WARRANTY

If after reviewing this manual you feel that your smoke alarm is
defective in any way, do not tamper with the unit.  Return it for
servicing to: Kidde Safety Europe, Mathisen Way, Colnbrook, SL
oHB, UK. (See Warranty for in-warranty returns).

 

Summary of Contents for PI9000 UK

Page 1: ...is smoke alarm It is an important part of your family s home safety plan You can trust this prod uct to provide the highest quality safety protection We know you expect nothing less when the lives of...

Page 2: ...S OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE ALARMS 6 MAINTENANCE 7 LIMITATIONS OF SMOKE ALARMS 8 GOOD...

Page 3: ...the room Ceiling mounting is preferred in ordinary residential construc tion For mobile home installation select locations carefully to avoid thermal barriers that may form at the ceiling For more de...

Page 4: ...utside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling In such units install the smoke...

Page 5: ...areas Kitchens Normal cooking may cause nuisance alarms If a kitchen alarm is desired it should have an alarm silence feature or be a photoelectric type Near fluorescent lights Electronic noise may c...

Page 6: ...e screws and anchors provided to secure the mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper insta...

Page 7: ...sist tab is engaged press down on the tamper resist tab and rotate the alarm off of the trim ring see figure 6 After installation test your alarm by depressing and holding down the test button for at...

Page 8: ...he red LED will flash every 30 40 seconds to indicate that the smoke alarm is operating properly Alarm Condition When the alarm senses products of combustion and goes into alarm the red LED will flash...

Page 9: ...alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if the alarm is located close to t...

Page 10: ...ANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL...

Page 11: ...different ways and are often unpredictable For maximum protection Kidde recom mends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the speci...

Page 12: ...e extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all s...

Page 13: ...is manufactured and dis tributed under license from the U S Nuclear Regulatory Commission 10 NFPA REQUIRED PROTECTION The National Fire Protection Association s Standard 72 provides the following inf...

Page 14: ...LOCAL FIRE DEPARTMENT AND INSURANCE COM PANY OF YOUR SMOKE ALARM INSTALLATION 11 CAUTION AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL FOR UNITED STATES ONLY Early warning fire detection is best a...

Page 15: ...dequate AC or DC electrical power This guarantee does not cover batteries This guarantee applies only to individuals situated in the United Kingdom This guarantee is nontransferrable MAKING A CLAIM UN...

Reviews: