6
3. Other Alarm Visual and Audible Indicators
Operational Mode
Visual Indications
Audible Indications
Action/Note:
normal (standby)
Green LED blink approx every
60 sec.
test (button press
when no alarm condi-
tion is present)
•
4 patterns of Red/Amber/Green.
•
Test: Red LED blinks in time with
alarm pattern.
•
Green LED fade on/off at test
complete
•
Button press sound
•
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4,
3, 2, 1."
•
3 long beeps, Voice "Fire!", 3 long
beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide,"
4 quick beeps, Voice "Test
Complete," Power on/reset sound.
•
Voice "Test Canceled" if button
pushed before test sequence begins.
Perform Test/Hush button
press once a week to verify
proper alarm operation
* Push/release button before
the countdown ends to
cancel test.
Smoke or co alarm
Memory (unit has
experienced a smoke
or co alarm event
within the last hour)
Red and Amber LED alternate on
1 sec, every 10 sec.
After button push: "Smoke
previously detected" or "Carbon
Monoxide previously detected"
only on the initiating alarm unit.
Push test button to clear
Alarm Memory. NOTE:
standard test sequence will
follow. (Push/release button
again to cancel test).
Smoke alarm Hush
Mode, (Hush
®
control)
Red LED blinks every 2 sec.
After button push: "Hush Mode
Activated." Smoke alarm pattern
stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke,
Alarm cannot be Hushed" Smoke
alarm pattern continues.)
This feature is to be used
only when a known alarm
condition, such as smoke
from cooking, activates
the alarm.
co alarm reset
None
After button push: CO alarm
pattern stops.
Unit is confirming if CO is
present or if it experienced a
nuisance situation. Re-alarm
means danger. Move to fresh
air and call 911.
Locate
None
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Use this to quickly locate the
alarm source and determine
if alarm is nuisance or real.
Smoke alarm Hush
Mode canceled
None
Voice message "Hush Mode
Canceled."
When smoke levels drop
below the alarm threshold,
the voice message "Hush
Mode Canceled" will occur .
initiating alarm,
(Multiple alarms in an
interconnected system)
Green LED blinks once per sec indi-
cating that this is the unit initiating
the alarm in an interconnected,
multiple alarm, system.
Unit in either Smoke or CO alarm
mode.
During alarm, the initiating
alarm red blink will be
interrupted by a green blink.