6. Installation / Mounting Instructions

WIRING INSTRUCTIONS FOR AC HARNESS 

!

 CAUTION! TURN OFF THE MAIN POWER TO THE CIRCUIT 

BEFORE WIRING THE ALARM.

•  For alarms that are used as single station, DO NOT CONNECT THE RED WIRE 

TO ANYTHING. Leave the red wire insulating cap in place to make certain 

that the red wire cannot contact any metal parts or the electrical box.

• When alarms are interconnected, all interconnected units must be 

powered from a single circuit.

• A maximum of 24 Kidde Safety devices may be interconnected in 

a multiple station arrangement. The interconnect system should 

not exceed the NFPA interconnect limit of 12 smoke alarms and/or 

18 alarms total (smoke, CO, Smoke/CO Combination, heat detector, 

etc.). With 18 alarms interconnected, it is still possible to interconnect 

up to a total of 6 remote signaling devices and /or relay modules (see 

below for details on interconnecting Kidde devices).

•  The following models can be interconnected using the standard AC 

wiring interconnect: i12020CA, i12020ACA, i12040CA, i12040ACA, 

i12060CA, i12060ACA, i12010SCA, i12010SCOCA, KN-SMFM-I-CA, 

KN-COB-ICB-CA, KN-COSM-IBCA, KN-COB-IC-CA, KN-COSM-ICA, 

KN-COP-IC-CA, KN-COPE-ICA, P12040CA, Pi2000CA, Pi2010CA, 

SM120X, CO120X, SLED177iCA, P4010ACLEDSCA.

•   The maximum wire run distance between the first and last unit in an  

  interconnected system is 305 m (1000’). 

WIRES ON ALARM HARNESS CONNECTED TO

Black  

 

Hot side of AC line

White  

 

Neutral side of AC line

Red  

 

Interconnect lines (red wires) of other  

 

 

units in the multiple station set up

Interconnect Wiring Diagram

 FIGURE 3

FUSE OR CIRCUIT BREAKER

RED

BLACK

WHITE

RED

BLACK

WHITE

First

Alarm

Additional

Alarm

Kidde Relay Module 

SM120X, CO120X

 or both 

Additional

Alarm

Optional 

Accessory

Summary of Contents for P4010ACLEDSCA

Page 1: ...take a few minutes to thoroughly read this user guide which should be saved for future reference and passed on to any subsequent owner Photoelectric Smoke Alarm with LED Strobe and Voice User Guide SI...

Page 2: ...ese combustible products from the kitchen If the alarm sounds check for fires first If a fire is discovered follow these steps Become thoroughly familiar with these items and review with all family me...

Page 3: ...fire department from your cell phone outside or from your neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so Do not reenter under any c...

Page 4: ...st Hush button on the initiating CO or Combination alarm unit will terminate the CO alarm on all interconnected units If the CO condition that caused the alarm in the first place continues the initiat...

Page 5: ...g less when the lives of your family are at stake Please take a few minutes to thoroughly read this user guide and save it for future reference Teach children how to respond to the alarms and that the...

Page 6: ...e by date 10 years from initial power up in permanent marker on the label prior to installing the unit Model Number P4010ACLEDSCA 3 wire interconnect unit Power 120 V AC 60Hz 863mA max wire in connect...

Page 7: ...t or Indirect and Supplementary Light Output 177 Candela minimum on axis measurement The following diagrams show that the light intensity gradually decreases as the viewing angle is increased Use this...

Page 8: ...s Photoelectric sensing alarms may detect visible fire particles associated with slow smouldering fires sooner than ionization alarms A battery powered alarm must have a battery of the specified type...

Page 9: ...arm in every Sleeping Room Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door c...

Page 10: ...OM FIRE EXTINGUISHERS SMOKE ALARMS CARBON MONOXIDE ALARMS SMOKE CO ALARM TOTAL HOME PROTECTION FIGURE 1C Install smoke alarms on sloped peaked or cathedral ceilings following the mounting guidelines o...

Page 11: ...IZONTAL DISTANCE FROM PEAK NOT IN THIS AREA ANYWHERE IN THIS AREA 0 9 m 3 MINIMUM BEST PLACEMENT S T A G N A N T A I R MINIMUM 10 cm 4 NEVER HERE ACCEPTABLE PLACEMENT 30 5 cm 12 MAXIMUM CEILING 10 cm...

Page 12: ...ection install at least one alarm close to the bedrooms For additional protection see Figure 1A WARNING Test your smoke alarm operation after mobile home has been in storage or unoccupied and at least...

Page 13: ...d be made by a qualified electrician and all wiring used shall be in accordance with codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the sa...

Page 14: ...ll possible to interconnect up to a total of 6 remote signaling devices and or relay modules see below for details on interconnecting Kidde devices The following models can be interconnected using the...

Page 15: ...o signal that power has been applied and a voice message will prompt you to push the test button If AC power is on at this time confirm the green LED is on constant 2 Rotate the unit fully onto the mo...

Page 16: ...strobe do not activate the unit must be replaced Weekly testing is required to ensure proper operation Erratic or low volume sound or no sound or no strobe activation from your alarm may indicate a de...

Page 17: ...ction What to do when the alarm sounds Smoke Alarm activation CO Alarm from an interconnected CO or Combo unit this unit is not a CO alarm Red LED blinks in time with alarm pattern Strobe will flash 4...

Page 18: ...ssage Low Bat tery Pile Faible will occur once every 15 minutes Ambient Light Sensor Feature Inhibits Low Battery chirps during the night The alarm should be replaced as soon as possible See section 1...

Page 19: ...8 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized by pushing the Test Hush button on the initiat...

Page 20: ...This alarm is equipped with a low battery monitor circuit While powered by AC the amber LED will blink 2 times a second and the unit will chirp once a minute followed by the voice message Low Battery...

Page 21: ...ion of Alarm WARNING Failure to DEACTIVATE alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard To Deactivate The Alarm Rotate the alarm counterclockwi...

Page 22: ...he alarm If the alarm is in Fault mode and the amber LED is blinking a fault code of 10 flashes the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not cle...

Page 23: ...h the sound and visual signals of a smoke a carbon monoxide and or strobe alarm and train them to leave your home when they hear or see it Practice a fire drill at least every six months including fir...

Page 24: ...e Once outside go to your selected meeting place and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire officials sa...

Page 25: ...ore Smoke Alarms Desirable Required number of smoke alarms as shown in Figure 1A and Figure 1B The required number of smoke alarms might not provide reliable early warning protection for those areas s...

Page 26: ...in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expens...

Reviews: