7. Alarm Visual and Audible Indicators
Alarm
Mode
Visual
Indications
Audible
Indications
Smoke or Fire
detected
3 blinks
synchronized
with audible
alarm
3 long beeps, voice message “Fire! Feu!”, 3 long
beeps repeating.
Carbon
Monoxide
detected
4 blinks
syncronized
with audible
alarm
4 quick beeps, voice message “Warning!
Carbon Monoxide! Monoxyde de carbone!”,
repeating(First 4-5 minutes - The repeating
pattern is 4 quick beeps, “Warning! Carbon
Monoxide! Monoxyde de carbone!”, 4 quick
beeps. After 4-5 minutes, the pattern is 4 quick
beeps, “Warning! Carbon Monoxide! Monoxyde
de carbone!” once every minute).
Operational
Mode
Visual
Indications
Audible
Indications
Note:
Normal
Operation
Blink once
every
60 seconds
None
LED will flash
every 60 seconds
for 10 minutes
following power on
or reset. After initial
10 minutes, LED will
flash once every
10 minutes
Test/Hush
Button Press
Blink with each
alarm pattern
Two sets of 3 long
beeps with voice “Fire!
Feu!” and two sets
of 4 quick beeps with
voice “Warning! Carbon
Monoxide! Monoxyde de
carbone!”
Test/Hush button
press will initiate test
sequence
Smoke Alarm
Hush
Blink once
every
10 seconds
Voice message “Hush mode
activated. Mode Hush
activé.” (The voice message
“Hush Mode Cancelled.
Mode Hush annulé.” occurs
if: 1. The button is pushed
again, and the smoke level is
below the Alarm level. 2. The
Hush mode timer expires,
(approximately 9 minutes),
and the smoke level is below
the Alarm level.)
Alarm hush feature
silences smoke alarm
for approximately
9 minutes.
The following table describes the visual and audible alarm conditions
the unit may encounter and illustrates how the unit will indicate normal
standby, alarm and error conditions.