6

8. Interconnecting with Kidde CO, Smoke and Heat
Alarms

When compatible Kidde smoke alarms and heat alarms are interconnected
to your CO alarm, they will only respond to a smoke or heat related event. 

When mixing Kidde alarms which have battery back-up with models
without battery back-up, be advised that the models without battery back-
up will not function during an A.C. power failure. 

Testing

When pressing the Test/Reset button, if the unit is operating properly,  the
red LED will flash and you will then hear a series of quick beeps for 4 sec-
onds, followed by 1/2 second of silence, followed by another series of
quick beeps.  Models with digital display will show            and then show a
number (usually around 200) for several seconds.  After internal testing is
complete,            will be displayed and the alarm will begin monitoring of
carbon monoxide.

If interconnected to Kidde Fyrnetics Smoke/Heat alarms, pressing the
Test/Reset button on the CO alarm will have no effect on the Smoke/Heat
alarms. The Smoke/Heat alarms will not be tested and will not alarm.
However, when pressing the Test button on an interconnected Smoke/Heat
alarm, the CO alarm will emit a Smoke/Fire audible and visual alarm pat-
tern of 3 long beeps, 1 second of silence, repeated. Note: You do not need
to press the Test button to take a CO reading.

Smoke/Heat Alarm Indicator

When an interconnected Kidde Fyrnetics smoke alarm detects smoke, or a
heat alarm detects 57

o

C, this unit will sound an alarm pattern of 3 long

beeps, followed by a 1 second silence. This cycle repeats as long as
smoke signal persists to alert you of the condition. In addition on digital dis-
play models the word "FirE" will scroll across the digital display. If this hap-
pens, leave the premises immediately by your escape plan and call the
emergency services.

WARNING:

This unit is not a smoke alarm and will not detect smoke or

fire. The digital model will only display "FirE" and alarm for Smoke/Fire if it
receives a signal from an interconnected Kidde Fyrnetics Smoke/Heat
alarm.

Note: 

A smoke/heat alarm situation will override a CO alarm condition.

Refer to Operator’s Manual for additional instructions on testing the alarms.

2512-7205-01.qxd:_  2008.4.1  2:05 PM  Page 6

Summary of Contents for Fyrnetics 423/9HIR

Page 1: ...Section 2 Recommended Locations for CO Alarms Section 3 Where not to install your alarm Section 4 Installing the Alarm Section 5 Battery Checking and Charging Section 6 Initial Checking and Testing of Alarm Section 7 Interconnect Wiring Section 8 Interconnecting with Kidde CO Smoke and Heat Alarms Section 9 Timing of Installing Section 10 Decorating Section 11 Ongoing Maintenance Section 12 Repair...

Page 2: ... 560 7 1 This would include Smoke CO Heat Alarms 2 Recommended Locations for CO Alarms Where To Install The CO Alarm The Kidde CO alarm should be mounted in or near bedrooms and living areas It is recommended that a Kidde CO alarm is installed on each level of a multi level home You may use the number and location of smoke alarms installed in the home according to current requirements as a guide t...

Page 3: ...rty areas e g boiler rooms Any location where the free flow of air to the alarm s vents could be interrupted e g behind curtains furniture Areas where routine maintenance or operating test reset button is dif ficult e g top of stairwells 3 Where not to install your alarm 3 4 Installing the Alarm These are mains powered alarms so isolate the mains supply before commencing installation They are for ...

Page 4: ...The Lithium Ion battery is to supply short term backup during a power cut Do not attempt to replace the battery as the alarm has no user serviceable parts Opening the alarm will invalidate the guarantee and could expose you to live parts Digital model only During the first 10 hour initial charge period or until the battery has charged Lb will be displayed along with the CO level usually 0 and with...

Page 5: ...e section 1 Total cable length between alarms must not exceed 250m 273yds and be 1 0mm in diameter 3 core and earth BS6243Y Wiring must conform to the IEE regulations BS7671 or latest edition Interconnection Interconnects directly with Kidde Fyrnetics Ion Smoke Alarms 123i 123 9hi 123 9hill 1SF23 9hi 1SF23 9hir 1SF23 9hire Photo Smoke Alarms 223i 223 9i 223 9hi 223 9ill 223 9hill 2SF23 9hi 2SF23 9...

Page 6: ...t alarms will not be tested and will not alarm However when pressing the Test button on an interconnected Smoke Heat alarm the CO alarm will emit a Smoke Fire audible and visual alarm pat tern of 3 long beeps 1 second of silence repeated Note You do not need to press the Test button to take a CO reading Smoke Heat Alarm Indicator When an interconnected Kidde Fyrnetics smoke alarm detects smoke or ...

Page 7: ...list of substances that at high levels can damage the sensor or cause temporary readings on the digital display that are not carbon monoxide readings Ethylene ethanol alcohol iso propanol benzene tolulene ethyl acetate hydrogen hydrogen sulfide sulfur dioxides most aerosol spray alcohol based products paint thinner solvent adhesive hair spray after shave lotion perfume auto fumes cold start and so...

Page 8: ...dditional strobe accessories to give a visual alarm CO Alarms are not a substitute for annual routine servicing of appli ances by a qualified installer Symptom 1 Green L E D not lit 2 Unit flashing Lb at power up 3 Alarm Beeping every 30 seconds 4 Alarm does not sound when test button pressed 5 Interconnected alarms do not sound when test button is pressed and held Possible cause solutions a Loss ...

Page 9: ...tered after the date of purchase or if it fails to operate due to incorrect selection siting installation maintenance or inadequate AC electrical power or damage caused by failure to abide by the instructions supplied The liability of Kidde Fyrnetics arising from the sale of this alarm or under the terms of this guarantee shall not in any case exceed the cost of replacement of the alarm in no case...

Page 10: ...or the property owner e g near Consumer Unit Kidde Safety Europe Mathisen Way Colnbrook SL3 0HB UK www kiddefyrnetics co uk Kidde Fyrnetics 2005 Lic No KM 98848 EN50291 2001 P N 810 1873 Rev B 2512 7205 01 Patent Pending 2512 7205 01 qxd _ 2008 4 1 2 05 PM Page 10 ...

Reviews: