NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL
FEATURE AND SOUND A CONTINUOUS ALARM.

CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THE
SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS.

LED INDICATORS:

This smoke alarm is equipped with red and green

LED indicators. The green LED (when illuminated) indicates the presence
of AC or battery backup power. The red LED operates in unison with the
sounder during alarm and error mode conditions:

Standby Condition:

The green LED will be lit continuously if AC power

is present or flash every 30 seconds if powered by battery backup only.

Alarm Condition:

When the alarm senses products of combustion and

goes into alarm, the red LED will flash with the sounder and the green
LED will flash once per second. The flashing red LED and pulsating alarm
will continue until the air is cleared. WHEN UNITS ARE INTERCONNECTED,
only the green LED of the alarm which senses the smoke or is being
tested (the originating unit) will flash. All other units in the interconnect
system will sound an alarm but their green LED’s will remain constat to
indicate AC power or flash once every 30 seconds when on battery backup.

Alarm Memory:

This smoke alarm is equipped with an alarm memory,

which provides a visual indication of when an alarm has been activated.
The green LED will flash once every 16 seconds to indicate the memory
condition (AC powered and battery backup). The memory will remain
activated until the button is pressed causing the alarm to rapidly beep 3
times and reset the alarm memory function. In an interconnected
installation only the memory of the originating alarm will be activated. If
the battery power is low due to insufficient charge, this feature is over
ridden and the green LED will function to indicate either AC power is
present or Battery backup operation

Hush

®

mode:

The green LED will blink every 3 seconds, indicating the

smoke alarm is in the Hush

®

mode.

Testing:

Test by pushing the Test/Hush button on the cover. This will

sound the alarm if the electronic circuitry and horn are working. In an
interconnected installation all interconnected alarms should sound when
the Test/Hush button on any of the interconnected alarm is pressed.
After completing its test cycle the Green LED will be off for
approximately 30 seconds while the unit completes its self test.

4. Operation and Testing

Summary of Contents for 900-0252

Page 1: ...nutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User s Guide 900 0252 With Rechargeable Battery Backup KN SMFM i...

Page 2: ...se steps and review with all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In le...

Page 3: ...ction of Kidde products to a non specified manufacturer s interconnect system or connection with non specified equipment from another manufacturer into an existing Kidde system could result in nuisanc...

Page 4: ...arms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing limitations Ionization sensing alarms may detect invisible fire particles associated...

Page 5: ...he ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential c...

Page 6: ...ORIZONTAL DISTANCE FROM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 0 9 m 3 0 9 m 3 NOT IN THIS AREA...

Page 7: ...n sloped peaked or cathedral ceilings at or within 0 9 m 3ft of the highest point measured horizontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 0 3m in 2 4 m 1 ft in 8 ft...

Page 8: ...larm silence feature or be a photoelectric type Near fluorescent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector guards unless the combination alarm and...

Page 9: ...er to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak voltages that will damage the alarm 3 Installation Instructions Wiring I...

Page 10: ...e into contact with any metal parts or the electrical box MOUNTING INSTRUCTIONS CAUTION This unit is sealed The cover is not removable 1 After selecting the proper smoke alarm location as described in...

Page 11: ...This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The HUSH feature cannot be activated unless the smoke alarm is sounding in the originating a...

Page 12: ...constat to indicate AC power or flash once every 30 seconds when on battery backup Alarm Memory This smoke alarm is equipped with an alarm memory which provides a visual indication of when an alarm h...

Page 13: ...e outside non recirculating type will also help remove these combustible products from the kitchen This model is equipped with a Hush feature that is extremely useful in a kitchen area or other areas...

Page 14: ...its end of life the label on the back of the unit should be pierced in the indicated location and the switch pressed to render the unit safe for disposal When doing so the alarm will produce 10 short...

Page 15: ...moke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a differen...

Page 16: ...als and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may...

Page 17: ...ended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room...

Page 18: ...or a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or cons...

Reviews: