5. Introduction, Product Features And Specifications
introduction
This alarm detects products of combustion using a multi-criteria optical sensor and carbon monoxide using an
electrochemical cell. Many times throughout this User Guide, we will refer to Carbon Monoxide as “CO.”
Ten (10) years after the unit was installed, this unit will automatically alert you that it is time to replace the unit.
This is called “End of Unit Life” mode. See Troubleshooting Guide. To help identify the date to replace the unit,
a label has been affixed to the side of the alarm. Write the “Install date” in the space provided, and then write
in the “Replace by” date (10 years from initial power up) in permanent marker on the label prior to installing the
unit. Two labels have been provided that have important information on what to do in case of a CO alarm. Place
one label at eye level on a wall near the alarm after it is mounted, and one near a fresh air source such as a door
or window.
product Features and Specifications:
•
Temperature Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
•
Humidity Operating range: 10-95% RH non-condensing
•
Audible Alarm: 85+ dB at 10’, 3.0 to 3.5 KHz pulsing alarm, with voice messages
“Fire!” and/or “Warning! Carbon Monoxide.”
•
Smoke Sensor: Multi-Criteria Optical
•
CO Sensor: Electrochemical
•
Voice message system
•
Smoke Alarm SMART Hush® Control
•
Powered by 120VAC (60 Hz, 53mA max, 20mA Ave., 9V battery back up) wire-in connector with front load
9V battery backup.
•
Hardwire interconnectable to other compatible alarms.
•
One large, user- friendly button.