INSTALLATION

Mounting

KickAss DRAWER refrigerators have been designed and constructed exclusively for 
recessed installation and installation that is in compliance with standard dimensions. The 
refrigerator must always be in a horizontal position, with the compressor’s rubber feet at 
the bottom. The compressor is capable of functioning at angles of up to 30°. The 
compressor can become damaged with any higher inclinations.

Ventilation

It is extremely important for the compressor/condensing unit located behind the 

refrigerator to be well ventilated so that the fresh air can enter at the bottom and 
pass behind the refrigerator, with the hot air being allowed to escape from the top or 
sides.

Electrical Connections

• Before turning on the appliance, check to make sure that the voltage of the electrical 

system and/or battery complies with that which is indicated on the unit’s data plate.

• Connect the refrigerator directly to the battery or to the relative main switch and make 

sure that the system is equipped with an electric device that’s capable of protecting the 
circuit against possible overcurrents.

• The product is supplied with a 10 A fuse. A separate switch that simultaneously 

disconnects the power cables must be installed upstream from the refrigerator. Check to 
make sure that this switch supports the 10 A current load.

SIZE OF THE ELECTRICAL CABLES

Always use cables of a suitable cross-section. The minimum cross-sections are listed in the table 
below:

Cross-

section in 

mm²

AWG section

Max 12 V cable length m/ft

Max 24V cable length m/ft

2.5

13

2.5/8

5/16

4

11

4/13

8/26

6

9

6/19

12/39

10

8

10/33

20/66

For system protection, the fuse must be installed in the positive wires (+) as close as possible to 
the battery. We recommend using 15 A fuses for 12 V and 7.5 A fuses for 24 V. If using a main 
switch, it must be able to withstand a minimum current of 20 A. Avoid extra junctions in wiring to 
prevent voltage drops that can influence battery protection settings.

4

Summary of Contents for KAF-30DS

Page 1: ...30L DC COMPRESSOR DRAWER FRIDGE KAF 30DS ...

Page 2: ...or Efficient electronic technology low energy consumption Multi voltage system DC 12 24 Volt and AC 220 240 Volt Adjustable low voltage battery protection IMPORTANT SAFETY SYMBOLS Warning Safety Directive Failure to observe this directive could lead to serious injury Caution Safety Directive Failure to observe this directive could lead to injury or damage to the appliance Note Important Information ...

Page 3: ...2 ...

Page 4: ...VDC Refrigerant gas and charge R134a 0 044 kg CFC Free CO2 eq 0 063 t Dimensions 260 x 440 x 695 mm Net weight 18 Kg Installed power 45 Watt SPECIFICATIONS PRODUCT FEATURES Slide out drawer Drawer latch Soft touch controls Power connection Compressor cooling vents 3 ...

Page 5: ...te Connect the refrigerator directly to the battery or to the relative main switch and make sure that the system is equipped with an electric device that s capable of protecting the circuit against possible overcurrents The product is supplied with a 10 A fuse A separate switch that simultaneously disconnects the power cables must be installed upstream from the refrigerator Check to make sure that...

Page 6: ...he offset1 value will appear This value can be changed from 8 to 8 using buttons 2 and 3 Press 1 to confirm the new data entered and go to setting for the next parameter The offset2 value will appear This value can be changed from 8 to 8 using buttons 2 and 3 Press 1 to confirm the new data entered and go to setting for the next parameter The offset3 value will appear This value can be changed from 8 t...

Page 7: ...GRAPHICAL DISPLAY OF THE SEQUENCE FOR SETTING THE PRO MENU 6 ...

Page 8: ...cated on the digital thermometer Offset Temperature Interval 1 T 6 C 2 12 C T 7 C 3 T 13 C Data which is used to align the temperature shown on the display with the actual internal temperature Adjustment for each offset can vary from 8 8 POWER OPTIONS LOW VOLTAGE PROTECTION In order to prevent excessive battery depletion a protection device shuts off the compressor in case of insufficient voltage and t...

Page 9: ... compressor starts up with the bridge the thermostat is defective Replace the thermostat The compressor only performs brief attempts at starting up There is insufficient voltage or else a drop in voltage during the attempt to start The protection device is activated The Batteries are drained Check the cables and connections remove any traces of oxidation or corrosion Charge the batteries start the m...

Page 10: ...otate the thermostat to off position If the refrigerator continues to function then there is continuity on the control unit Correct the problem on thermostat connections make sure the bridge is present on C and P and not on C and T on the electronic control unit Rotate the thermostat to off position If the compressor switches off but it is impossible to regulate temperature replace the thermostat or ...

Page 11: ...de portal including videos user guides and product tips so you can view or download the latest product information at any time This also helps to save our environment which we are committed to just as much as we are committed to our customer service To get started with this product please visit and search for your SKU code ONLINE USER GUIDES SCAN QR CODE USERGUIDES KICKASS COM AU ...

Page 12: ...ave not been used in accordance with the KickAss user guide or are outside the warranty terms and conditions AUSTRALIAN DIRECT PRODUCT QUALITY QUESTIONS AND COMMENTS Customer Support For any technical or warranty enquires please visit our customer service portal at warranty kickass com au Please visit us at kickass com au or email us at support kickass com au This KickAss product comes with a 3 ye...

Page 13: ......

Reviews: