The fuse blows.
The wrong fuse is being
used. Defective electronic
control unit.
Check the fuse: see table in section
4.4. Replace the electronic control unit.
The compressor is
operating intermittently.
Battery low or electrical
cables in poor condition.
Check wiring conditions, examining for
loose connections, rust or corosion. If
wiring needs to be replaced, see the
manual for correct sizing. If wiring is in
good condition, check battery function
and replace if in poor condition.
The compressor never
stops (correct fridge
performance)
Incorrect thermostat
connection on the electronic
control unit. Thermostat
broken. Condensation
is not working properly,
evaporator cools but not
enough to cause the
thermostat to stop the
compressor.
Rotate the thermostat to off position. If
the refrigerator continues to function,
then there is continuity on the control
unit. Correct the problem on thermostat
connections (make sure the bridge
is present on C and P and not on C
and T on the electronic control unit).
Rotate the thermostat to off position.
If the compressor switches off but it is
impossible to regulate temperature,
replace the thermostat or recharge the
cooling system.
The compressor never
stops (poor fridge
performance)
Environment very hot +
insufficient ventilation or
little gas in the refrigerant
circuit.
Check ventilation. The compressor
must be installed in a well-ventilated
location. If possible, remove the
refrigerator from the installation hole.
If the refrigerator operates better,
improve ventilation, consulting the
manual for correct installation. If
ventilation is instead optimal, check
for the presence of gas in the system,
contacting a specialised technician.