13
6.2 Quiet Night Mode
When charging a battery at high current, the charger fan turns on to cool the unit down. This
can at times be undesirable, especially when trying to get some sleep at your campsite.
While charging a battery (after pre-charging period), holding the mode button for 4 seconds
will make the charger go into Quiet Night Mode, which lowers the output current to 5A, and at
the same time turns off the fan. This mode can be activated from any charge setting.
When activated the charging mode icons will flash while in this mode. For example, if the
charger is in fast AGM mode before entering Quiet Night Mode, the fast AGM mode icons will
start flashing once the charger goes into Quiet Night Mode. The original AGM fast Charging
mode will be remembered.
6.3 Recondition Mode
Recondition mode can be used on AGM batteries only to give the battery a specialised
charge if the battery has not been used in some time. We recommend you consult your
battery manual or vendor when using Recondition mode as it can shorten battery life.
Recondition mode is selected using the standard selection via the mode button as described
above. Note that in recondition mode the charge stage will stop at stage 6 as shown below.
Once the display reaches this stage the recondition mode has finished.
BATTERY
240V AC
Note:
that #6 (RECON) only appears
while in AGM (RECON) mode.