M.FAEP50.1001-01 17/12/18
9
UK
1. SAFETY WARNINGS
This dehumidifier must be always connected using earthed electrical plugs as required for all electrical appliances; FRAL
Company declines any responsibility for any danger or damage whenever this norm is not complied with.
Any intervention on the machine using any instrument must be carried out only by a qualified technician.
When the machine is connected with a power socket, it must be in vertical position and any rough move must be avoided
because it could cause some water to come into contact with electrical parts; it is therefore recommended to remove the
plug from the socket before moving around the dehumidifier; if any water may have been spread on the machine, following
some rough handling of the same, then the dehumidifier must be turned off and can be started up again only after 8 hours.
Correct Distance: this dehumidifier draws in the air from the back and lets out through the front side grille: therefore the
back panel, which supports the air filter, must be kept at a minimum distance of 15 cm from the wall.
The dehumidifier, moreover, must not be set running in narrow areas, which do not allow a proper diffusion in the room of
the air coming out from the grille. It is, instead, allowed to set the machine sides near the walls.
This dehumidifier has been designed and manufactured in compliance with the strictest safety rules. Therefore, pointed
instruments (screw drivers, wool needles or similar ones) are not to be inserted in the grille or in the opening of the back
panel when it is opened to remove the filter.
The machine must not be cleaned using water. To clean the machine use a wet cloth. Remember to disconnect the plug from
the socket before.
The front panel should not be used to lay over it cloths or other things: it could cause damages or dangers.
The filter should be cleaned periodically (normally every month), but in dusty rooms it should be cleaned more often (see
chapter 7). Remember that when the filter is dirty, the air circulation and, consequently, the machine performance is reduced.
2. PERTINENT TECHNICAL NORMS AND REGULATIONS
The dehumidifier has been designed and manufactured in conformity to all following European Norms and Regulations:
MACHINES NORMS (
2006/42/CE - 17.05.2006
); SECURITY REGULATIONS FOR LOW TENSION APPLIANCES
2006/95/CE -
12.12.2006
; ELECTROMAGNETIC COMPATIBILITY (EMC)
–
2004/108/CE
– 15.12.2004
.
It is hereby certified that this Dehumidifier
conform to the: IEC Regulations
CEI-EN 60335-2-40, CEI-EN 55014-1, 55014-2.
The machine is built according to RoHS European Norms: 2011/65/UE year 2011 and CEI-EN 50581.
3. DESCRIPTION OF THE MACHINE
FUNCTIONING
This
dehumidifier
is a refrigerating cycle dehumidifier: its functioning is based on a physical principle according to which the air,
coming into contact with a cooled surface, it wets the surface by covering it with humidity in the form of condensed drops, or ice
with low ambient temperature. What really happens is that a refrigerating machine maintains in a refrigerated state the coil through
which is conveyed the incoming air that, in this way, is cooled and dehumidified. Then the air, passing through a warm heat-
exchanger, heats up and returns in the room dehumidified and at a slightly higher temperature.
Summary of Contents for 55L
Page 19: ...M FAEP50 1001 01 17 12 18 19 ...