background image

 

Notices 

© Keysight Technologies, Inc. 

2018 
No part of this manual may be 

reproduced in any form or by any 

means (including electronic 

storage and retrieval or translation 

into a foreign language) without 

prior agreement and written 

consent from Keysight 

Technologies, Inc. as governed by 

United States and international 

copyright laws. 

Trademark 
Acknowledgements 

N/A 

Manual Part Number 

5992-3110EN 

Print Date 

December 2018  
Published in USA 
Keysight Technologies Inc.  

1400 Fountaingrove Parkway  

Santa Rosa, CA 95403 

Warranty 

THE MATERIAL CONTAINED IN 

THIS DOCUMENT IS PROVIDED 

“AS IS,” AND IS SUBJECT TO 

BEING CHANGED, WITHOUT 

NOTICE, IN FUTURE EDITIONS. 

FURTHER, TO THE MAXIMUM 

EXTENT PERMITTED BY 

APPLICABLE LAW, KEYSIGHT 

DISCLAIMS  ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED 

WITH REGARD TO THIS MANUAL 

AND ANY INFORMATION 

CONTAINED HEREIN, INCLUDING 

BUT NOT LIMITED TO THE 

IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY 

INFORMATION CONTAINED 

HEREIN. SHOULD KEYSIGHT AND 

THE USER HAVE A SEPARATE 

WRITTEN AGREEMENT WITH 

WARRANTY TERMS COVERING 

THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL. 

Technology Licenses 

The hardware and/or software 

described in this document are 

furnished under a license and may 

be used or copied only in 

accordance with the terms of such 

license. 
 

Restricted Rights Legend 

If software is for use in the 

performance of a U.S. Government 

prime contract or subcontract, 

Software is delivered and licensed 

as “Commercial computer 

software” as defined in DFAR 

252.227-7014 (June 1995), or as 

a “commercial item” as defined in 

FAR 2.101(a) or as “Restricted 

computer software” as defined in 

FAR 52.227-19 (June 1987) or any 

equivalent agency regulation or 

contract clause. Use, duplication 

or disclosure of Software is 

subject to Keysight Technologies’ 

standard commercial license 

terms, and non-DOD Departments 

and Agencies of the U.S. 

Government will receive no 

greater than Restricted Rights as 

defined in FAR 52.227-19(c)(1-2) 

(June 1987). U.S. Government 

users will receive no greater than 

Limited Rights as defined in FAR 

52.227-14 (June 1987) or DFAR 

252.227-7015 (b)(2) (November 

1995), as applicable in any 

technical data. 

Safety Notices 

 

CAUTION notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or 

adhered to, could result in damage 

to the product or loss of important 

data. Do not proceed beyond a 

CAUTION notice until the indicated 

conditions are fully understood and 

met. 

 

WARNING notice denotes a 

hazard. It calls attention to an 

operating procedure, practice, or the 

like that, if not correctly performed 

or adhered to, could result in 

personal injury or death. Do not 

proceed beyond a WARNING notice 

until the indicated conditions are 

fully understood and met.

Summary of Contents for N6731B

Page 1: ...idesthedocumentation forthefollowinginstruments N6731B through N6736B N6741B through N6746B N6751A through N6756A N6761A through N6766A N6773A through N6777A N6781A through N6786A N6791A and N6792A Declassification and Security Document ...

Page 2: ...cribed in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 ...

Page 3: ...y Buyer shall pay all shipping charges duties and taxes Where to Find the Latest Information Documentation is updated periodically For the latest information about these products including instrument software upgrades application information and product information see the following URL https www keysight com en pc 851482 n6700 modular power system nid 35714 0 00 cc US lc eng To receive the latest...

Page 4: ... Sales and Service Offices 5 2 Products Covered by this Document 6 3 Security Terms and Definitions 7 4 Instrument Memory 8 5 Summary of Memory Declassification Procedures 11 6 Procedure for Declassifying a Faulty Instrument 15 7 References 16 ...

Page 5: ...the Internet at http www keysight com find assist If you do not have access to the Internet please contact your field engineer In any correspondence or telephone conversation refer to the instrument by its model number and full serial number With this information the Keysight representative can determine whether your unit is still within its warranty period ...

Page 6: ...y the user in the instrument that needs to be saved is properly backed up before attempting to clear any of the instrument memory The model s user guide explains how to store states outside the product Keysight Technologies cannot be held responsible for any lost files or data resulting from the clearing or sanitization of memory Be sure to read this document entirely before proceeding with any fi...

Page 7: ...or both Keysight declassification procedures are designed to meet the requirements specified in DoD 5220 22 M Chapter 8 Sanitization As defined in Section 8 301b of DoD 5220 22 M sanitization is the process of removing or eradicating stored data so that the data cannot be recovered using any known technology Instrument sanitization is typically required when an instrument is moved from a secure to...

Page 8: ...and Size Writable During Normal Operation Data Retained When Powered Off Purpose Contents Data Input Method Location in Instrument and Remarks Clearing or Sanitization Procedure EEPROM Note 1 16K bit No Yes Used to store Model Number Serial Number Calibration data Calibration Date Programmed before installed and by Firmware operations cal routines Main PCA See Table 4 and See Table 5 FPGA 146KB 19...

Page 9: ...ion Date Programmed before installed and by Firmware operations cal routines Main PCA See Table 4 and See Table 5 FPGA 1 4MB No No Power module measurement and control infrastructure Programmed During power up in Mainframe DPM Power Cycle 32M bit SPI Flash No No Memory not used for module when installed in mainframe Memory not used in module when installed in mainframe DPM Power Cycle Notes 1 When...

Page 10: ...on in Instrument and Remarks Sanitization Procedure EEPROM 16K bit No Yes Used to store Model Number Serial Number Calibration data Calibration Date Programmed before installed and by Firmware operations cal routines Main PCA See Table 4 and See Table 5 FPGA 3 8MB No No Power module measurement and control infrastructure Programmed During power up in Mainframe DPM Power Cycle ...

Page 11: ...of user data For Sanitizing N6700C N6701C and N6702C mainframes From the Front Panel Menu Select System Admin Login enter password Sanitize Enter or select Display will show Warning that all user data will be Sanitized and unit will be rebooted Press Enter or Select wait 15 seconds for unit to reboot before shutting power off The mainframe is now Sanitized When using remote interface send SYSTem S...

Page 12: ...election 6 Erase any data displayed under date by pressing the back arrow key and press the Enter key 7 Press the Back key Select Save and the press the Enter key Press the Enter key again The unit will display Cal changes have been saved 8 Press the Back key three times 9 Select the Logout menu item and press the Enter key Press the Enter key again to log out 10 Repeat for all modules in the main...

Page 13: ...or Login Logout enter 6 Select nonvolatile RAM Reset enter 7 Select Reset enter Note pressing enter clears all Non Volatile memory to factory defaults and the internal drive will be cleared 8 Wait for unit to prompt you to cycle power 9 After you cycle power the saved states for all modules in the mainframe will be reset to default values NV Ram is now cleared B To clear module calibration date fi...

Page 14: ...ly module by pressing channel key 15 Enter the Administrator menu by pressing 16 Menu key 17 Select System enter 18 Select Admin enter 19 Select Login enter 20 Enter password enter 21 Enter 22 Select Cal enter 23 Select Date enter 24 Use the Back Space key to delete all the characters in the Date field and then press the Enter key 25 Press Back Key 26 Select Save enter 27 Select Save enter 28 Note...

Page 15: ...formation cannot be cleared using the front panel or the remote interface The only choice in this situation is to take manual steps to remove any user information that may be present To manually remove any user information from the power module you must remove the module from the mainframe and destroy it ...

Page 16: ...e downloaded in Acrobat PDF format from http www dss mil isp fac_clear download_nispom html 2 ISFO Process Manual for the Certification and Accreditation of Classified Systems under the NISPOM Defense Security Service DSS cleared industries may request a copy of this document via email by following the instructions at http www dss mil isp odaa request html ...

Page 17: ...This information is subject to change without notice Keysight Technologies 2018 December 2018 5992 3110EN www keysight com ...

Reviews: