Installation Note  N5232-90101   

  3

Description of the Upgrade 

This upgrade adds the following items to your N5231A Option 200, N5232A Option 200, or N5239A Option 200 

network analyzer:
• 60 dB source step attenuators with brackets and wire harnesses
• front panel jumpers
• cable guards for front panel jumpers
• front panel overlay replacement
• new  cables
After installation of this upgrade, your analyzer will be an N5231A Option 216, N5232A Option 216, or N5239A 

Option 216.

Getting Assistance from Keysight

By internet 

or 

phone, get assistance with all your test and measurement needs.

Contacting Keysight

Assistance with test and measurements needs and information on finding a local Keysight office are available 

on the Web at:

 

http://www.keysight.com/find/assist

If you do not have access to the Internet, please contact your Keysight field engineer.

NOTE

 In any correspondence or telephone conversation, refer to the Keysight product by its model 

number and full serial number. With this information, the Keysight representative can 

determine whether your product is still within its warranty period.

If You Have Problems With the Upgrade Kit Contents

Keysight stands behind the quality of the upgrade kit contents. If you have problems with any item in the kit, 

email Keysight Component Test Division (CTD) Support at 

[email protected]

, or telephone the 

CTD Hotline at (707) 577-6802 and leave a voice mail message. Please include details of the problem.

Summary of Contents for N5231A Option 200

Page 1: ...e Test Set and Source Attenuators Upgrade Kit Installation Note To Upgrade PNA N5231A N5232A or N5239A Option 200 to Option 216 Upgrade Kit Order Numbers N5231AU 216 N5232AU 216 or N5239AU 216 Keysigh...

Page 2: ...Installation Note N5232 90101 1...

Page 3: ...al item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Softw...

Page 4: ...urements needs and information on finding a local Keysight office are available on the Web at http www keysight com find assist If you do not have access to the Internet please contact your Keysight f...

Page 5: ...rade adjustments and full instrument calibration To view the equipment list click the Chapter 3 bookmark Tests and Adjustments in the PDF Service Guide1 License Key Redemption NOTE The enclosed Option...

Page 6: ...rvice Guide is displayed scroll through the Contents section bookmarks to locate the information needed Protecting Your Workspace from Electrostatic Discharge For information click on the Chapter 1 bo...

Page 7: ...scription Qty Part Number T 10 TORX driver set to 9 in lbs 1 02 N m 1 N A T 20 TORX driver set to 21 in lbs 2 38 N m 1 N A 5 16 in 8 mm nutsetter or open end torque wrench set to 10 in lbs 1 13 N m 1...

Page 8: ...5232 80005 Front panel jumper cable guard 2 N5242 00029 Dust caps for test ports 2 1401 0214 W11 RF cable A21 MASSY to A29 60 dB step attenuator 1 N5232 20026 W12 RF cable A21 MASSY to A30 test port 2...

Page 9: ...n this upgrade kit It is normal for some of these items to remain unused after the upgrade is completed Wire harness A19 test set motherboard J8 to A29 60 dB step attenuator 1 8121 0982 Wire harness A...

Page 10: ...a Keyword and Verify the Information Step 2 Remove the Outer Cover Step 4 Remove the Front Panel Assembly Step 5 Remove Some Existing Cables Step 6 Assemble the A29 and A30 Source Attenuator Assembli...

Page 11: ...For instructions click the Chapter 7 bookmark Removing the Covers in the PDF Service Guide1 Step 4 Remove the Front Panel Assembly For instructions click the Chapter 7 bookmark Removing and Replacing...

Page 12: ...le N5235 20040 A4 13 5 GHz Source Synthesizer board to test set deck cable bracket W10 N5232 20081 A24 mixer brick to test set deck cable bracket Step 6 Assemble the A29 and A30 Source Attenuator Asse...

Page 13: ...specially wire harness connections Incorrect connections can destroy components resulting in additional customer costs CAUTION Be careful not to damage the center pins of the semirigid cables Some fle...

Page 14: ...32 20031 Figure 3 Location of Cable Clamps to Secure W19 W22 and W23 W19 N5232 20025 A21 MASSY to REF 2 SOURCE OUT As shown in Figure 3 install two cable clamps part number 1400 1334 to secure W19 par...

Page 15: ...le bracket W12 N5232 20019 A21 MASSY to A30 test port 2 source attenuator W18 N5232 20032 A21 MASSY to REF 1 SOURCE OUT As shown in Figure 4 install one cable clamp part number 1400 1334 to secure W18...

Page 16: ...connect to the front panel bulkhead These cables were shipped with hex nuts If not already done secure the cable connectors to the front panel bulkhead with the hex nuts torquing to 21 in lbs Step 10...

Page 17: ...16 Installation Note N5232 90101 Figure 5 Lower Front Panel Overlay Replacement...

Page 18: ...f the procedure Although a 4 port PNA is shown in the graphic the concept is the same for the 2 port PNA New parts are listed in Table 1 on page 7 1 Remove the protective backing from the new front pa...

Page 19: ...front panel jumper cables part number N5222 20091 Torque to 10 in lbs Figure 7 Front Panel Jumper Cables Installation Step 14 Reinstall the Inner Cover For instructions click the Chapter 7 bookmark Re...

Page 20: ...t 4 Using the keyboard enter the license key in the box provided The license key is printed on the the license message you received from Keysight Enter this key exactly as it is printed on the message...

Page 21: ...structions click the Chapter 3 bookmark Tests and Adjustments in the PDF Service Guide1 If you experience difficulty with the basic functioning of the analyzer contact Keysight Refer to Contacting Key...

Page 22: ...This information is subject to change without notice Keysight Technologies 2012 2014 August 2014 N5232 90101 N5232 90101 www keysight com...

Reviews: