background image

Notices

© Keysight Technologies, Inc. 2012-2016

No part of this manual may be reproduced in 

any form or by any means (including 

electronic storage and retrieval or 

translation into a foreign language) without 

prior agreement and written consent from 

Keysight Technologies, Inc. as governed by 

United States and international copyright 

laws.

Manual Part Number

N2771-92013

Edition

Sixth edition, 2016

Published in USA

Keysight Technologies, Inc.

1400 Fountaingrove Parkway

Santa Rosa, CA 95403 USA

Warranty

The material contained in this document 

is provided “as is,” and is subject to 

being changed, without notice, in future 

editions. Further, to the maximum 

extent permitted by applicable law, 

Keysight disclaims all warranties, either 

express or implied, with regard to this 

manual and any information contained 

herein, including but not limited to the 

implied warranties of merchantability 

and fitness for a particular purpose. 

Keysight shall not be liable for errors or 

for incidental or consequential damages 

in connection with the furnishing, use, 

or performance of this document or of 

any information contained herein. 

Should Keysight and the user have a 

separate written agreement with 

warranty terms covering the material in 

this document that conflict with these 

terms, the warranty terms in the 

separate agreement shall control.

Technology Licenses 

The hardware and/or software described in 

this document are furnished under a license 

and may be used or copied only in 

accordance with the terms of such license.

U.S. Government Rights

The Software is "commercial computer 

software," as defined by Federal Acquisition 

Regulation ("FAR") 2.101. Pursuant to FAR 

12.212 and 27.405-3 and Department of 

Defense FAR Supplement ("DFARS") 

227.7202, the U.S. government acquires 

commercial computer software under the 

same terms by which the software is 

customarily provided to the public. 

Accordingly, Keysight provides the Software 

to U.S. government customers under its 

standard commercial license, which is 

embodied in its End User License Agreement 

(EULA), a copy of which can be found at 

www.keysight.com/find/sweula

. The 

license set forth in the EULA represents the 

exclusive authority by which the U.S. 

government may use, modify, distribute, or 

disclose the Software. The EULA and the 

license set forth therein, does not require or 

permit, among other things, that Keysight: 

(1) Furnish technical information related to 

commercial computer software or 

commercial computer software 

documentation that is not customarily 

provided to the public; or (2) Relinquish to, 

or otherwise provide, the government rights 

in excess of these rights customarily 

provided to the public to use, modify, 

reproduce, release, perform, display, or 

disclose commercial computer software or 

commercial computer software 

documentation. No additional government 

requirements beyond those set forth in the 

EULA shall apply, except to the extent that 

those terms, rights, or licenses are explicitly 

required from all providers of commercial 

computer software pursuant to the FAR and 

the DFARS and are set forth specifically in 

writing elsewhere in the EULA. Keysight 

shall be under no obligation to update, 

revise or otherwise modify the Software. 

With respect to any technical data as 

defined by FAR 2.101, pursuant to FAR 

12.211 and 27.404.2 and DFARS 227.7102, 

the U.S. government acquires no greater 

than Limited Rights as defined in FAR 27.401 

or DFAR 227.7103-5 (c), as applicable in any 

technical data.

Safety Notices

CAUTION

CAUTION

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or 

adhered to, could result in damage 

to the product or loss of important 

data. Do not proceed beyond a 

CAU-

TION

 notice until the indicated con-

ditions are fully understood and 

met.

WARNING

A WARNING notice denotes a haz-

ard. It calls attention to an operat-

ing procedure, practice, or the like 

that, if not correctly performed or 

adhered to, could result in personal 

injury or death. Do not proceed 

beyond a WARNING notice until the 

indicated conditions are fully 

understood and met.

WEEE Compliance

This product complies with 

the WEEE Directive 

2012/19/EU marking 

requirements. The affixed 

label indicates that you 

must not discard this 

electrical/electronic product 

in domestic household waste.

Product Category: With reference to the 

equipment types in the WEEE Directive 

Annex I, this product is classed as a 

"Monitoring and Control Instrumentation" 

product.

Do not dispose in domestic household 

waste.

To return unwanted products, contact your 

local Keysight office, or see 

www.keysight.com

 for more information.

Summary of Contents for N2771B

Page 1: ...Keysight N2771B 15 kV High Voltage Probe User s Guide...

Page 2: ...odify distribute or disclose the Software The EULA and the license set forth therein does not require or permit among other things that Keysight 1 Furnish technical information related to commercial c...

Page 3: ...and nominal input capacitance between 6 and 20 pF The N2771B is a 1000 1 divider which extends the voltage measurement capability to maximum 15 kV DC AC peak 10 kVrms AC or 30 kVpeak 20 ns pulse widt...

Page 4: ...ory I CAT I only Do not use the probe for measurements performed on circuits defined by any other measurement category or transient overvoltages of more than 1500V Refer to IEC Measurement Category De...

Page 5: ...nnecting the probe WARNING The probe body should be kept clean and free of any conductive contamination Refer to the section on cleaning WARNING The ground lead is critical to the safe operation of th...

Page 6: ...II is for measurements performed on circuits directly connected to the low voltage installation Example Household appliances portable tools and similar equipment Measurement Category III CAT III Measu...

Page 7: ...r than the oscilloscope waveform if the probe attenuation on the oscilloscope has been set to 1 1 8 Turn off the high voltage source 9 Disconnect the Keysight N2771B High Voltage Probe from the high v...

Page 8: ...8 kV DC or 5 kV AC rms Keysight recommends that an interval of 5 minutes be taken between measurements WARNING This high voltage probe is designed for use within Measurement Category I CAT I only Do...

Page 9: ...imately 10 volts amplitude 4 Adjust the oscilloscope time base for 20 s div 5 Use a trimmer tool to adjust the compensation capacitor for the flattest pulse top See the figure below for the location o...

Page 10: ...tio For input capacitance of 6 pF to 20 pF 1000 1 Bandwidth Designed For Use In 50 MHz 3 dB POLLUTION DEGREE 2 Input Resistance Operating Temperature 100 M when terminated by 1 M 0 C to 50 C Cable Len...

Page 11: ...Voltage Derating 11 Voltage Derating The following graph shows the voltage versus frequency derating curve for the Keysight N2771B High Voltage Probe Figure 2 Voltage Versus Frequency Derating Curve...

Page 12: ...12 Contacting Keysight Contacting Keysight Information on contacting Keysight Technologies can be found at www keysight com find contactus...

Reviews: