Two-Oscilloscope System

2

Keysight UXR-Series MultiScope Hardware Configuration Guide

15

 

7

Connect the oscilloscopes to the Leader oscilloscope (or external host 

computer) through the desired remote interface connection (LAN, USB, etc.).

8

If these are the last oscilloscopes to be connected, se

Chapter 4

, “Next Steps,” 

starting on page 23.

Summary of Contents for MultiScope UXR Series

Page 1: ...Keysight UXR Series MultiScope Hardware Configuration Guide ...

Page 2: ...S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not require or permit amo...

Page 3: ...ning the necessary cables adapters and power dividers are required N2164A UXR Series Multi Frame Base Kit First Two Frames N2165A UXR Series Multi Frame Expansion Kit Add One Frame The N2164A and N2165A rack mount expansion accessories are set up so that you can expand your system one oscilloscope at a time NOTE The Infiniium UXR Series oscilloscope software supports up to 40 channels in a MultiSc...

Page 4: ... an external host computer MultiScope software is included as a standard feature This software allows time synchronized acquisitions for systems of up to ten oscilloscopes with very low oscilloscope to oscilloscope jitter and drift This software can be used to configure capture and store real time voltage signals Not Included MultiScope systems also require Equipment rack Rack mount kits N2156A fo...

Page 5: ...n in the following table After you have set up and connected the MultiScope system see Chapter 4 Next Steps starting on page 23 See Also The Infiniium UXR Series oscilloscope software s online help for information on using the MultiScope Hosted Instruments software of channels required 4 ch oscilloscopes of channels required 2 ch oscilloscopes Configuration required See 5 8 3 4 2 oscilloscope conf...

Page 6: ...6 Keysight UXR Series MultiScope Hardware Configuration Guide ...

Page 7: ...n Kit 13 Connecting the Oscilloscopes 14 3 Three to Five Oscilloscope Systems Expansion Equipment Required 18 Mounting Oscilloscopes in Rack 19 Connecting the Equipment 20 Parts in the N2165A Add One Expansion Kit 20 Connecting the Follower 2 Through Follower 4 Oscilloscopes 21 4 Next Steps Calibrate the Oscilloscopes in the MultiScope System 23 Use MultiScope Control Software 24 Infiniium Oscillo...

Page 8: ...8 Keysight UXR Series MultiScope Hardware Configuration Guide ...

Page 9: ...illoscopes environmental and rack Oscilloscopes are sensitive measurement instruments and some environmental conditions must be present to ensure that the oscilloscope delivers the best possible measurement accuracy Refer to the Infiniium UXR Series Real Time Oscilloscopes User s Guide for information on power requirements airflow cooling requirements and rack cabinet requirements ...

Page 10: ...10 Keysight UXR Series MultiScope Hardware Configuration Guide 1 UXR Series MultiScope System Requirements ...

Page 11: ... Equipment Required Table 1 Equipment Required for Two Oscilloscope Rack Mount System Model Description Quantity N2164A UXR Series Multi Frame Base Kit First Two Frames 1 N2156A Rack mount kit 2 Figure 2 Expansion Accessories Required for Two Oscilloscope Rack Mount System UXR Series oscilloscope UXR Series oscilloscope N2164A 2 oscilloscope kit for rack Rack 2 oscilloscope rack mount system ...

Page 12: ... Rack Mount Kit User s Guide mount oscilloscopes in their designated rack locations NOTE Locate oscilloscopes in the rack so that the overall rack center of gravity is about half way up the rack Because of cable lengths use the recommended power divider location relative to the Leader and Follower oscilloscope locations Figure 3 Oscilloscope Locations in Rack Leader Oscilloscope 7U Top of Rack Fol...

Page 13: ...m These parts are used to create a long cable for performing channel deskew Part number Qty Description 54964 61632 5 1 m phase stable cable 54964 60401 1 6 way splitter assembly with rack mount shelf 1250 3745 4 50 Ω SMA terminator Part number Qty Description 54964 61632 2 1 m phase stable cable 1250 2818 2 Right angle male to female SMA adapter 1250 3758 1 Female female SMA adapter connector sav...

Page 14: ...puts 3 Connect one 54964 61632 cable from the Leader Sample_CLK_Out output to the power divider input 4 Connect two 54964 61632 cables between the power divider assembly outputs and the oscilloscopes Sample_CLK_In inputs 5 Connect one 54964 61632 cable between the Leader Trig Out and Follower 1 Aux Trig In connectors 6 Connect one 54964 61632 cable between the Leader Reference CLK Out and Follower...

Page 15: ...re Configuration Guide 15 7 Connect the oscilloscopes to the Leader oscilloscope or external host computer through the desired remote interface connection LAN USB etc 8 If these are the last oscilloscopes to be connected see Chapter 4 Next Steps starting on page 23 ...

Page 16: ...16 Keysight UXR Series MultiScope Hardware Configuration Guide 2 Two Oscilloscope System ...

Page 17: ...17 Keysight UXR Series MultiScope Hardware Configuration Guide 3 Three to Five Oscilloscope Systems Expansion Equipment Required 18 Mounting Oscilloscopes in Rack 19 Connecting the Equipment 20 ...

Page 18: ... Frame of scopes 2 N2156A Rack mount kit of scopes Figure 4 Expansion Accessories Required for Three to Five Oscilloscope Rack Mount System UXR Series oscilloscope UXR Series oscilloscope N2164A 2 oscilloscope kit for rack UXR Series oscilloscope N2165A 1 oscilloscope expansion kit UXR Series oscilloscope N2165A 1 oscilloscope expansion kit UXR Series oscilloscope N2165A 1 oscilloscope expansion k...

Page 19: ...oscilloscopes in their designated rack locations NOTE Locate oscilloscopes in the rack so that the overall rack center of gravity is about half way up the rack Because of cable lengths use the recommended power divider location relative to the Leader and Follower oscilloscope locations Figure 5 Oscilloscope Locations in Rack Top of Rack Leader Oscilloscope 7U Follower 1 Oscilloscope 7U Follower 2 ...

Page 20: ... Series MultiScope Hardware Configuration Guide 3 Three to Five Oscilloscope Systems Connecting the Equipment Parts in the N2165A Add One Expansion Kit Part number Qty Description 54964 61632 3 1 m phase stable cable ...

Page 21: ... Follower 4 Power divider Place 1250 3745 terminators on all unused divider outputs Connections Back Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out...

Page 22: ...e power divider output that will be used for the oscilloscope 2 Connect one 54964 61632 cable between the power divider output and the oscilloscope s Sample_CLK_In input 3 Connect one 54964 61632 cable between the previous oscilloscope s Trig Out connector to this oscilloscope s Aux Trig In connector 4 Connect one 54964 61632 cable between the previous oscilloscope s Reference CLK Out connector to...

Page 23: ...perating temperature of the oscilloscopes in the rack s or stackmount configuration once the entire system has reached a stable thermal condition The temperature deviation from the previous calibration is displayed in the Calibration dialog box of each oscilloscope If the inlet air temperature is not within the calibration temperature range the oscilloscope will provide a visual warning on the scr...

Page 24: ...om the Infiniium Offline software you have only edge and glitch trigger modes No additional computer is required to run the Infiniium Offline software No space for an additional computer is necessary MultiScope software is included as a standard feature Refer to the Infiniium oscilloscope software s Online Help for instructions on setting up and controlling the MultiScope system In particular note...

Page 25: ...nfiguration Guide 25 Host Computer Requirements For the D9010BSEO Infiniium Offline oscilloscope analysis software Keysight recommends a host computer with A Windows 10 64 bit operating system with at least 8 GBytes of RAM and 25 GBytes of hard drive space ...

Page 26: ...lti Frame Base Kit The parts used to perform channel deskew are These parts are used to create a long cable that can be connected from Cal Out to each input channel in the MultiScope system Part number Qty Description 54964 61632 2 1 m phase stable cable 1250 2818 2 Right angle male to female SMA adapter 1250 3758 1 Female female SMA adapter 3 5 mm f 1250 3347 1 Push on male SMA to female SMA adap...

Page 27: ...50 2818 right angle SMA adapter are included with the UXR Series oscilloscope UXR Series oscilloscope input connector type Adapter needed for channel deskew cable connection 3 5 mm 5061 5311 adapter 3 5 mm female to female 1 85 mm 5061 5311 adapter 3 5 mm female to female 1 0 mm 5067 1393 adapter 1 mm ruggedized female to 2 92 mm female ...

Page 28: ...28 Keysight UXR Series MultiScope Hardware Configuration Guide 4 Next Steps ...

Page 29: ...es 3 F final steps 23 follower oscilloscope 3 H host computer 4 host computer requirements 25 I in the box MultiScope control software 24 IO Libraries Suite 24 M MultiScope hardware configuration 3 MultiScope product overview 3 N N2156A rack mount kit 11 18 N2164A UXR Series Multi Frame Base Kit First Two Frames 3 11 13 18 N2165A UXR Series Multi Frame Expansion Kit Add One Frame 3 18 20 P parts i...

Page 30: ...30 Keysight UXR Series MultiScope Hardware Configuration Guide Index ...

Reviews: