Notices

© Keysight Technologies, Inc. 2015
No part of this manual may be repro-

duced in any form or by any means 

(including electronic storage and retrieval 

or translation into a foreign language) 

without prior agreement and written con-

sent from Keysight Technologies, Inc. as 

governed by United States and interna-

tional copyright laws.

Manual Part Number

5000-0039

Edition

Eleventh Edition, August 2015

Printed in

Malaysia

Published by

Keysight Technologies, Inc.

900 S. Taft Ave.

Loveland, CO 80537 USA

Trademarks

PICMG

®

, Compact PCI

® 

are registered

trademarks of the PCI Industrial Com-

puter Manufacturers Group.
AdvancedTCA

®

 

and ATCA are registered

trademarks of the PCI Industrial Com-

puter Manufacturers Group.
PCI-SIG

®

, PCI Express

®

, and PCIe

®

 

are

registered trademarks of PCI-SIG.

Te

chnology Licenses 

The hardware and/or software described 

in this document are furnished under a 

license and may be used or copied only in 

accordance with the terms of such 

license.

Declaration of Conformity

Declarations of Conformity for this prod-

uct and for other Keysight products may 

be downloaded from the Web. Go to 

http://keysight.com/go/conformity

.

 You can then search by product number 

to find the latest Declaration of Confor-

mity. 

U.S. Government Rights

The Software is “commercial computer 

software,” as defined by Federal Acquisi-

tion Regulation (“FAR”) 2.101. Pursuant 

to FAR 12.212 and 27.405-3 and Depart-

ment of Defense FAR Supplement 

(“DFARS”) 227.7202, the U.S. govern-

ment acquires commercial computer 

software under the same terms by which 

the software is customarily provided to 

the public. Accordingly, Keysight pro-

vides the Software to U.S. government 

customers under its standard commercial 

license, which is embodied in its End 

User License Agreement (EULA), a copy 

of which can be found at 

http://

www.keysight.com/find/sweula

The 

license set forth in the EULA represents 

the exclusive authority by which the U.S. 

government may use, modify, distribute, 

or disclose the Software. The EULA and 

the license set forth therein, does not 

require or permit, among other things, 

that Keysight: (1) Furnish technical infor-

mation related to commercial computer 

software or commercial computer soft-

ware documentation that is not custom-

arily provided to the public; or (2) 

Relinquish to, or otherwise provide, the 

government rights in excess of these 

rights customarily provided to the public 

to use, modify, reproduce, release, per-

form, display, or disclose commercial 

computer software or commercial com-

puter software documentation. No addi-

tional government requirements beyond 

those set forth in the EULA shall apply, 

except to the extent that those terms, 

rights, or licenses are explicitly required 

from all providers of commercial com-

puter software pursuant to the FAR and 

the DFARS and are set forth specifically 

in writing elsewhere in the EULA. Key-

sight shall be under no obligation to 

update, revise or otherwise modify the 

Software. With respect to any technical 

data as defined by FAR 2.101, pursuant 

to FAR 12.211 and 27.404.2 and DFARS 

227.7102, the U.S. government acquires 

no greater than Limited Rights as defined 

in FAR 27.401 or DFAR 227.7103-5 (c), as 

applicable in any technical data.

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” AND 

IS SUBJECT TO BEING CHANGED, 

WITHOUT NOTICE, IN FUTURE EDI-

TIONS. FURTHER, TO THE MAXIMUM 

EXTENT PERMITTED BY APPLICABLE 

LAW, KEYSIGHT DISCLAIMS ALL WAR-

RANTIES, EITHER EXPRESS OR IMPLIED, 

WITH REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT LIMITED 

TO THE IMPLIED WARRANTIES OF MER-

CHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE. KEYSIGHT 

SHALL NOT BE LIABLE FOR ERRORS OR 

FOR INCIDENTAL OR CONSEQUENTIAL 

DAMAGES IN CONNECTION WITH THE 

FURNISHING, USE, OR PERFORMANCE 

OF THIS DOCUMENT OR OF ANY INFOR-

MATION CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A SEP-

ARATE WRITTEN AGREEMENT WITH 

WARRANTY TERMS COVERING THE 

MATERIAL IN THIS DOCUMENT THAT 

CONFLICT WITH THESE TERMS, THE 

WARRANTY TERMS IN THE SEPARATE 

AGREEMENT SHALL CONTROL.
Keysight Technologies does not warrant 

third-party system-level (combination of 

chassis, controllers, modules, etc.) per-

formance, safety, or regulatory compli-

ance unless specifically stated.

Safety Information

A CAUTION denotes a hazard. It calls 

attention to an operating procedure 

or practice that, if not correctly per-

formed or adhered to, could result in 

damage to the product or loss of 

important data. Do not proceed 

beyond a CAUTION notice until the 

indicated conditions are fully under-

stood and met. 

A WARNING denotes a hazard. It 

calls attention to an operating pro-

cedure or practice, that, if not cor-

rectly performed or adhered to, 

could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 

met. 

Summary of Contents for E4451-67000

Page 1: ...buy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of th...

Page 2: ...Keysight Power Distribution Unit PDU Installation Guide For use with Keysight PDU kits and PDU installation kits for Keysight racks ...

Page 3: ... rights in excess of these rights customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No addi tional government requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of comme...

Page 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod uct have been impaired either through physical damage excessive moisture or any other reason REMOVE POWER and do not use the product until safe operation can be verified by service trained personnel ...

Page 5: ... this ISM device complies with the Canadian ICES 001 This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use Forty years is the expected useful life of this product South Korean Class A EMC Declara tion this equipment is Class A suitable for professional use and is for use in electromagnetic environments out...

Page 6: ...llation Guide v Contents General Information 6 E7685A PDU Installation Kit Contents 7 Tools Required 7 PDU Kit Contents 7 PDU Specifications 9 General Installation Information 10 Installation procedure 10 Connecting the Old Style Switch 20 ...

Page 7: ...sight E7685A PDU Installation Kit allows the installation of any of the following PDU kits The above listed PDU kits are intended to be used only in the following Keysight rack enclosures E3661B E3662B and E7590A The low voltage master switch removes power only from the PDU outlet receptacles To completely remove power from the PDU and rack system the PDU power cord must be removed from the premis...

Page 8: ...llation Kit This kit provides hardware and rack components required to complete the installation The installation of a second PDU does not require an additional kit However you will need the kit s switch and hardware if the first PDU was not switched and you are adding a switched PDU The voltage of a second PDU must match that of the installed PDU for correct operation of the illuminated switch Wh...

Page 9: ...Guide 8 All 3 Machine Screw Torx T25 10 32x0 5 inch p n 2680 0278 All 2 Washer external tooth 10 p n 2190 0565 All 1 Nut Hex w Ext tooth lock washer 10 32 p n 2740 0003 All 1 Cable assembly ground p n C2786 60065 PDU Kit Number Quantity Description ...

Page 10: ...5A 1 IEC 320 C19 Receptacle 10 IEC 320 C13 Receptacles Operating Temperature 0 C to 40 C 0 C to 40 C 0 C to 40 C 0 C to 40 C Operating Humidity 5 to 80 RH non condensing 5 to 80 RH non condensing 5 to 80 RH non condensing 5 to 80 RH non condensing Operating Environment Indoor Location Indoor Location Indoor Location Indoor Location Input 100 120V 50 60 Hz N America 200 240V 50 60 Hz International ...

Page 11: ... switched D Second PDU Unswitched first one was switched E Second PDU Switched first one was unswitched Needs PDU Installation Kit F Second PDU Unswitched first one was also unswitched A shaded cell means the step applies A non shaded cell means that the step does not apply Step A B C D E F 1 Turn off power to the rack and disconnect AC power Failure to disconnect AC power could result in a severe...

Page 12: ...ews securing the top cap to the frame at the rear of the rack Slide the top cap towards the rear and liftoff the top cap completely See Figure 1 Step A B C D E F 3 If your rack is configured with a rear door open the door and remove the four screws securing the side cover to the rear door hinges Figure 1 Removing the top cap ...

Page 13: ...over to the base of the rack enclosure Lift the side cover slightly up and remove completely See Figure 2 Step A B C D E F 5 Remove the three screw used to secure the non switchable forehead assembly completely Retain the three screws as they will be re used in step 12 See Figure 3 Figure 2 Removing the side covers ...

Page 14: ...kets see the table below Attach the two PDU brackets using four 10 32 x 0 5 inch machine screws See Figures 4 and 5 Clip Nut Placement Rack Size Top PDU Bracket Bottom PDU Bracket Door Catch 1100mm 4th Increment Mark 16th Increment Mar 1st Increment Mar 1300mm 7th Increment Mar 26th Increment Mar 4th Increment Mar 1600mm 7th Increment Mar 25th Increment Mar 13th Increment Mar 2000mm 16th Increment...

Page 15: ...Keysight Power Distribution Unit Installation Guide 14 Figure 4 Attaching sheet metal clip nuts to the column Figure 5 Attaching the PDU brackets ...

Page 16: ...cond PDU place the second PDU against the PDU brackets and align the outer holes on the brackets with the mounting holes of the PDU Secure using 10 32 x 0 5 screws from the kit See Figure 6 Figure 6 Attaching the PDUs Step A B C D E F 8 Attach one end of the PDU ground cable assembly to the PDU at the bottom of the PDU using one 10 ext tooth star washer and one 10 31 x 0 5 machine screw Make sure ...

Page 17: ...nal wiring terminals power cord or supplied cord set Whenever it is likely that the protection has been impaired disconnect the power cord until the ground has been restored Protect from Shock Hazards As the number of instruments that connect to a PDU increases the magnitude of leakage current also increases The magnitude of the leakage current depends on the characteristics of each instrument To ...

Page 18: ... as shown See Figure 7 Step A B C D E F 10 Route the PDU switch cable harness up through the provided channel at the top of the rack enclosure and secure the cable harness with the pre mounted cable clips See Figure 8 Step A B C D E F 11 Install the power switch supplied with your PDU Installation Kit Align the switch so that the LED indicator is toward the left side when viewed from the front and...

Page 19: ...nto the spade terminals on the back of the switch See Figure 9 Connection from the PDU front panel switch harness and the switch in the forehead must be made correctly to ensure normal PDU operation Failure to do so can result in PDU failure or inconsistent PDU operation The power switch supplied has five terminals If you have an older installation with a six terminal switch see Connecting the Old...

Page 20: ...itch The power switch supplied has five terminals If you have an older installation with a six terminal switch see Connecting the Old Style Switch on page 20 The low voltage master switch removes power only from the PDU outlet receptacles To completely remove power from the PDU and rack system the PDU power cord must be removed from the premise electrical system or if the rack is connected to a de...

Page 21: ...on the right side when installed If your system has this older six terminal switch the correct wiring connections are as shown in Figure 10 below Figure 10 Main Power Switch Connection old style switch If you replace the old six terminal switch in your rack installation with the new five terminal switch provided in the PDU Installation Kit you must wire the PDU s as shown in Figure 9 The low volta...

Page 22: ...21 Keysight Power Distribution Unit Installation Guide Connecting the Old Style Switch ...

Page 23: ...This information is subject to change without notice Keysight Technologies 2015 Edition 11 August 2015 Published in USA 5000 0039 www keysight com ...

Page 24: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...