background image

 

© 2019 UTC Fire & Security Americas Corporation, Inc. 

1 / 4 

P/N 1077855 (ML) • REV B • ISS 12JUN19 

 

ATS1330 Power Distribution Board Installation 
Sheet 

EN  DE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN: Installation Sheet 

Description 

The power distribution board, model ATS1330, provides a 
simple means of star connecting ATS bus devices. It is fitted 
with a single protected input port and five paralleled output 
ports, providing either the traditional power and comms or 
power alone. It is a standard board size and provides a power 
OK LED (Figure 2, item 8) for easy diagnosis. 

The module has an incoming and outgoing data bus / power 
connection to achieve i.e. a proper stub connection for an 
Advisor Master bus reader.  

Mounting location 

The ATS1330 PCB (Figure 1) can be mounted in any Advisor 
Master cabinet, which supports the size B board.  

Connecting the ATS1330 

Figure 2 

(1)  ATS control panel (Mains powered device) 
(2)  TERM 

— termination link  

(3)  GND 

— earthing link 

(4)  Building earth 

(5)  Remote arming station (RAS) 
(6)  Shield connection between mains powered and non-mains 

powered device(s) 

(7)  4-door DGP (mains powered device) 
(8)  Power OK LED 
(9)  DGP (mains powered device i.e. ATS1201) 

TERM link fitted on first and last devices on the LAN. In a "star" 
wiring configuration the TERM link is only fitted on the devices 
at the ends of the two longest LAN cable runs. 

Recommended LAN cable 

WCAT52 

— 2 pair twisted shielded data cable. 

Note: 

The shield of each length of data cable is only 

connected at one end of a mains powered device with 
earthing. The shield of the data cable cannot be connected at 
the ATS1330. In case of a non-mains powered device, the 
shield should be connected to the shield of the nearest mains 
powered device (please refer to the shield connection between 
device 5 and 7 in Figure 2). 

Jumper settings 

Input 

Outputs 

 

D+, D

− = POWER 

D+, D

− = DATA 

P+ (12 VDC) 

P+ 

P+ 

P

− (GND) 

P

− 

P

− 

 

Reviews: