2 Installing the N1000A

n

Advanced Eye Analysis

n

Data Analytics Web Service Software

n

Enhanced Jitter Analysis

n

Equalizers (CTLE, DFE, LFE)

n

FlexDCA Remote Access Software

n

FlexEye Independent Eye Acquisition and Analysis

n

InfiniiSim-DCA Waveform Transformation Toolset

n

NRZ TDEC Measurement

n

PAM-N Analysis Software

n

Partial TDECQ Measurement and Equalizer

n

TDECQ Measurement and Equalizer

n

Unrestricted Data File Import

n

User Defined Measurements and Opterators

n

Keysight Arbitrary Waveform Generator Control

N1010200A Manufacturing Software Package. Provides the following features
that, on the 86100D, were included in options:

n

Data Analytics Web Service Software

n

Enhanced Impedance and S-Parameters

n

FlexDCA Remote Access Software

n

FlexEye Independent Eye Acquisition and Analysis

n

NRZ TDEC Measurement

n

PAM-N Analysis Software

n

TDECQ Measurement and Equalizer

N1010300A Signal Integrity Software Package. Provides the following features
that, on the 86100D, were included in options:

n

Automatic Fixture Removal in TDR Mode

n

Data Analytics Web Service Software

n

Enhanced Impedance and S-Parameters

n

FlexDCA Remote Access Software

n

User Defined Measurements and Operators

N1000A Quick Start Guide

19

Summary of Contents for DCA-X Series

Page 1: ...Keysight N1000A DCA X Series Wide Bandwidth Oscilloscope Quick Start Guide...

Page 2: ...commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find swe ula The license set forth in the EULA represents the exclusiv...

Page 3: ...ftware Options 18 Step 2 Work at a Static Safe Workstation 20 Grounding Receptacle 21 Daily ESD Self Check 21 Step 3 Position the N1000A 23 Step 4 Install the Modules 25 Step 5 Connect the Keyboard an...

Page 4: ...ntial requirements of the European Low Voltage Dir ective as well as current editions of the following standards dates and editions are cited in the Declaration of Conformity 42 COMPLIANCE WITH CANADI...

Page 5: ...formation 15 This chapter introduces you to the N1000A and contains important safety information To install your N1000A refer to Chapter 2 Installing the N1000A on page 17 The following picture shows...

Page 6: ...you should consider the following points to maintain security and protect your N1000A n Install Windows security updates as soon as they become available n Consider installing anti virus software n W...

Page 7: ...1 Introduction Front Panel Features Figure 3 Front Panel Features N1000A Quick Start Guide 7...

Page 8: ...1 Introduction Rear Panel Features Figure 4 Rear Panel Features 8 N1000A Quick Start Guide...

Page 9: ...module slots Although the instrument is not damaged when running with uncovered module bay slots the altered air flow may affect measurement accuracy All documentation including specifications for plu...

Page 10: ...1 Introduction include the N1090 2 4 series oscilloscopes and the N107x series clock recovery DCA Ms 10 N1000A Quick Start Guide...

Page 11: ...ectors or Electrical Con nectors If flammable fluids are used to clean connectors the fluid shall not be placed on the instrument during use or when connected to mains voltage Cleaning the connectors...

Page 12: ...disconnect the Keysight Technologies Model N1000A from mains before cleaning Use a dry cloth or one slightly dampened with water to clean the external case parts Do not attempt to clean internally Do...

Page 13: ...optical channels These adapters connect onto the front panel optical channel connectors FC PC adapters come pre installed on new optical modules Changing fiber optic adapters is easy Simply hand turn...

Page 14: ...Fiber Optic Adapters Description Keysight Part Number Diamond HMS 10 81000AI FC PC 81000FI SC 81000KI DIN 81000SI ST 81000VI Table 1 Front Panel Fiber Optic Adapters for Optical Channels 14 N1000A Qui...

Page 15: ...lass I Product provided with a protective earthing ground incorporated in the power cord The mains plug shall only be inserted in a socket outlet provided with a protective earth contact Any interrupt...

Page 16: ...further recommends that the maximum operating temperature of the cabinet be reduced 10 C from the lowest of the maximum operating temperature of a single instrument If there are any concerns or speci...

Page 17: ...ts and the trigger input circuit can be damaged by electrostatic discharge ESD Therefore avoid applying static discharges to the front panel input connectors Prior to connecting any coaxial cable to t...

Page 18: ...adapters or connector savers either pre installed or in their own packaging Package Contents n N1000A DCA X Series Wide Bandwidth Oscilloscope n Keyboard USB n Mouse USB n Power cord n Module bay fill...

Page 19: ...or Control N1010200A Manufacturing Software Package Provides the following features that on the 86100D were included in options n Data Analytics Web Service Software n Enhanced Impedance and S Paramet...

Page 20: ...wrist strap combination n Conductive floor mat and heel strap combination Figure 6 Example of Static Safe Workstation The following suggestions may reduce ESD damage that occurs during testing and ser...

Page 21: ...to prevent buildup of static charge Wear a wrist strap or heel strap Grounding Receptacle If the instrument has a grounding receptacle you can plug the wrist strap into the grounding receptacle For ex...

Page 22: ...an approved static attention label on the outside 8 Make sure that all cleaners solvents coatings and sprays used at your workstation are types approved by your ESD Coordinator 9 Put on wrist strap an...

Page 23: ...characteristic 20 5 kg 43 lb Module characteristic 1 2 kg 2 6 lb Dimensions excluding handle Without front connectors and rear feet 221 mm H x 426 mm W x 530 mm D 8 7 inch x 16 76 inch x 20 9 inch Wit...

Page 24: ...nts may cause product damage and serious injury Install the instrument so that the detachable power cord is readily identifiable and is easily reached by the operator The detachable power cord is the...

Page 25: ...be installed in any of the four slots Two slot modules can be installed in slots 1 2 or 3 4 but not 2 3 Three slot modules can be installed in slots 1 2 3 only 2 While gently pressing on the top inch...

Page 26: ...ur own Since the N1000A has a touch screen the use of these devices is optional When connecting or using a mouse or keyboard always consider ergonomic principles After completing the installation clic...

Page 27: ...ower Cord Connection to N1000A This instrument has auto ranging line voltage input be sure the supply voltage is within the specified range and that voltage fluctuations do not to exceed 10 percent of...

Page 28: ...andby switch Figure 11 Location of ON Standby Button 2 Wait while the instrument boots up During the process you will be asked to accept the Windows 10 End User License Agreement EULA Once accep ted t...

Page 29: ...you should avoid changing The front panel ON Standby switch places the instrument in standby The instrument is still energized When you press the ON Standby switch to place the instrument in standby m...

Page 30: ...File Exit to close the N1000A DCA application and view the Windows desktop 4 Use Windows to setup your instrument with the appropriate client protocol and configuration for your LAN If you do not kno...

Page 31: ...icate that you must use to install the license on your N1000A Refer to the instrument s help system for information on installing licenses Step 10 Connect a Printer Optional You can connect a printer...

Page 32: ...xternal Display Optional 1 Connect your display to the rear panel Display Port or VGA connector 2 Refer to Windows Help for information on using a Windows second desktop feature Figure 15 External Dis...

Page 33: ...moved and then reinserted n A change in the temperature of the mainframe exceeds 5 C compared to the temperature of the last vertical amplitude calibration T 5 C n The time since the last calibration...

Page 34: ...ases cal ibration accuracy 4 In the dialog box select a tab that represents the module that you want to calibrate 5 Calibrations with a green check mark are valid Select any items without a green chec...

Page 35: ...the N1000A and on FlexDCA s menu click n Help User s Guide to open learn how to use the instrument n Help Programmer s Guide to learn how to remote control the instrument via SCPI commands n Help Spe...

Page 36: ...with its sensitive data never has to leave your site Keysight does not need your hard disk to perform the calibration The hard disk includes both drive C INFINIIUM and drive D USER Drive C contains t...

Page 37: ...ch to the standby position 2 Remove the power cord 3 Locate the hard disk on the N1000A s rear panel as shown in Figure 18 Figure 18 Removable Hard Disk 4 Turn the locking screw counter clockwise to r...

Page 38: ...o the instrument s hard disk To declassify instrument memory 1 Optional Press the Clear button in the N1000A s Calibration dialog box to clear mainframe user timebase calibration data and optical dark...

Page 39: ...3 Removable Hard Disk 39 N1000A Quick Start Guide...

Page 40: ...te the required nature of the line module input power The chassis ground symbol The chassis ground symbol is used to indicate a chassis connection The CE marking is a registered trademark of the Europ...

Page 41: ...YYY ZZZZ This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as of August 13 2005 All electric and electronic equipment are required to be separate...

Page 42: ...IAN EMC REQUIREMENTS This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB du Canada EMC Complies with the essential requirements of the European EMC Directive a...

Page 43: ...rument Markings and Regulatory Information Acoustic statement European Machinery Directive Acoustic noise emission LpA 70 dB Operator position Normal operation mode per ISO 7779 43 N1000A Quick Start...

Page 44: ...ng Keysight For technical assistance with the contact your local Keysight Call Center n In the Americas call 1 800 829 4444 n In other regions visit http www keysight com find assist 44 N1000A Quick S...

Page 45: ...ies will notify you of the cost of the repair after examining the unit Remember to always make backups of important files Data stored on the instrument hard disk may be erased after a repair You can r...

Page 46: ...y of damage caused by electrostatic discharge n For instruments weighing less than 54 kg 120 lb use a double walled corrugated cardboard carton of 159 kg 350 lb test strength n The carton must be larg...

Page 47: ...5 Contacting Keysight 47 N1000A Quick Start Guide...

Page 48: ...ile sharing 30 front panel features 7 G grounding receptacle 21 H hard disk removable 36 I instrument markings 40 ISM1 A 40 K keyboard 18 26 L LAN connecting to 30 licenses installing 31 line cord 27...

Reviews: