background image

2

Keysight 33210A Retrofit Instructions

Notices

Copyright Notice

© Keysight Technologies 2008 - 2017
No part of this manual may be repro-

duced in any form or by any means 

(including electronic storage and 

retrieval or translation into a foreign 

language) without prior agreement and 

written consent from Keysight Technol-

ogies as governed by United States and 

international copyright laws.

Manual Part Number

33210-90020

Edition

Edition 2, October 1, 2017

Printed in:

Printed in Malaysia

Published by:

Keysight Technologies

Bayan Lepas Free Industrial Zone,

11900 Penang, Malaysia

Technology Licenses 

The hardware and/or software 

described in this document are fur-

nished under a license and may be 

used or copied only in accordance with 

the terms of such license.

Declaration of Conformity

Declarations of Conformity for this 

product and for other Keysight prod-

ucts may be downloaded from the 

Web. Go to 

http://www.keysight.com/

go/conformity

. You can then search by 

product number to find the latest Dec-

laration of Conformity.

U.S. Government Rights

The Software is “commercial computer 

software,” as defined by Federal Acqui-

sition Regulation (“FAR”) 2.101. Pursu-

ant to FAR 12.212 and 27.405-3 and 

Department of Defense FAR Supple-

ment (“DFARS”) 227.7202, the U.S. 

government acquires commercial com-

puter software under the same terms 

by which the software is customarily 

provided to the public. Accordingly, 

Keysight provides the Software to U.S. 

government customers under its stan-

dard commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of which can 

be found at 

http://www.keysight.com/

find/sweula

. The license set forth in the 

EULA represents the exclusive authority 

by which the U.S. government may use, 

modify, distribute, or disclose the Soft-

ware. The EULA and the license set 

forth therein, does not require or per-

mit, among other things, that Keysight: 

(1) Furnish technical information 

related to commercial computer soft-

ware or commercial computer software 

documentation that is not customarily 

provided to the public; or (2) Relinquish 

to, or otherwise provide, the govern-

ment rights in excess of these rights 

customarily provided to the public to 

use, modify, reproduce, release, per-

form, display, or disclose commercial 

computer software or commercial com-

puter software documentation. No 

additional government requirements 

beyond those set forth in the EULA 

shall apply, except to the extent that 

those terms, rights, or licenses are 

explicitly required from all providers of 

commercial computer software pursu-

ant to the FAR and the DFARS and are 

set forth specifically in writing else-

where in the EULA. Keysight shall be 

under no obligation to update, revise or 

otherwise modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant to FAR 

12.211 and 27.404.2 and DFARS 

227.7102, the U.S. government 

acquires no greater than Limited Rights 

as defined in FAR 27.401 or DFAR 

227.7103-5 (c), as applicable in any 

technical data.

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO THE 

MAXIMUM EXTENT PERMITTED BY 

APPLICABLE LAW, KEYSIGHT DIS-

CLAIMS ALL WARRANTIES, EITHER 

EXPRESS OR IMPLIED, WITH REGARD 

TO THIS MANUAL AND ANY INFORMA-

TION CONTAINED HEREIN, INCLUD-

ING BUT NOT LIMITED TO THE 

IMPLIED WARRANTIES OF MER-

CHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE. KEYSIGHT 

SHALL NOT BE LIABLE FOR ERRORS 

OR FOR INCIDENTAL OR CONSE-

QUENTIAL DAMAGES IN CONNECTION 

WITH THE FURNISHING, USE, OR 

PERFORMANCE OF THIS DOCUMENT 

OR OF ANY INFORMATION CON-

TAINED HEREIN. SHOULD KEYSIGHT 

AND THE USER HAVE A SEPARATE 

WRITTEN AGREEMENT WITH WAR-

RANTY TERMS COVERING THE MATE-

RIAL IN THIS DOCUMENT THAT 

CONFLICT WITH THESE TERMS, THE 

WARRANTY TERMS IN THE SEPARATE 

AGREEMENT SHALL CONTROL.

Safety Information

CAUTION

A CAUTION notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in damage to the product 

or loss of important data. Do not pro-

ceed beyond a CAUTION notice until 

the indicated conditions are fully 

understood and met.

WARNING

A WARNING notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in personal injury or death. 

Do not proceed beyond a WARNING 

notice until the indicated conditions are 

fully understood and met.

Summary of Contents for 33210-80001

Page 1: ...Keysight 33210A 10 MHz Function Arbitrary Waveform Generator Installation Instructions for 33210 80001 Retrofit Kit Retrofit Instructions ...

Page 2: ...ghts customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No additional government requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of commercial computer software pursu ...

Page 3: ...ng and Control Instrument product The affixed product label is as shown below Do not dispose in domestic household waste To return this unwanted instrument contact your nearest Keysight Service Center or visit http about keysight com en companyinfo environment takeback shtml for more information Sales and Technical Support To contact Keysight for sales and technical support refer to the support li...

Page 4: ...4 Keysight 33210A Retrofit Instructions THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Page 5: ...Retrofit Kit This guide shows how to install the Option 001 External Timebase Reference assembly into the Keysight 33210A This assembly can be installed on all Keysight 33210A instruments all serial numbers that were not shipped with Option 001 installed The Keysight 33210A Function Arbitrary Waveform Generator User s Guide contains instructions on using the features identified as option 001 only ...

Page 6: ...ternal Timebase Reference 6 Keysight 33210A Retrofit Instructions Installing the Timebase Assembly 1 Turn off the power Remove all cables from the instrument 2 Rotate the handle upright and pull off 3 Pull off the instrument bumpers ...

Page 7: ...ve the rear bezel 5 Slide off the instrument cover Loosen Screws Torx T 20 Slide Cover Off WARNING SHOCK HAZARD Make sure that the power cable has been removed from the instrument before proceeding Dangerous voltages may be encountered inside the instrument chassis at any time when the power cord is connected to power even with the power switch turned off ...

Page 8: ...m the chassis CAUTION Electrostatic discharge ESD can damage components on unprotected circuit boards Use static safe procedures when handling circuit boards Avoid high static areas such as carpeted floors If an anti static wrist strap is available its use is recommended Otherwise touch the metal instrument chassis to discharge static electricity before removing the timebase assembly from its anti...

Page 9: ...o the side 9 Remove the two plastic caps from the back panel The holes in the back panel for the 10 MHz In and 10 MHz Out connectors are capped in all instruments that do not have Option 001 installed Locate the plastic caps and from inside the chassis compress the retention tabs and push each cap out through the back panel Keyed connector Push out both plastic caps ...

Page 10: ...en them with the hex nuts and lock washers provided The installed assembly should be component side up as shown below c Tighten the hex nuts with a 9 16 inch open end or adjustable wrench to secure the assembly Do not overtighten just one quarter turn past hand tight 11 Reassemble the instrument by reversing steps 1 through 8 The Keysight 33210A is ready to use No software updates are required The...

Page 11: ...ion Installing the External Timebase Reference assembly has no effect on the instrument s calibration No recalibration is necessary unless it is time for a scheduled calibration Refer to the Keysight 33210A 10 MHz Function Arbitrary Waveform Generator Service Guide for further information about calibration ...

Page 12: ...1 Keysight 33210A Option 001 External Timebase Reference 12 Keysight 33210A Retrofit Instructions THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Page 13: ...n is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2008 2017 Edition 2 October 1 2017 Printed in Malaysia 33210 90020 33210 90020 www keysight com ...