U3047AM08
Controlling the Test Set
Address and Data example: addr.data (3)
0.0
16.1
32.2
Channel: (4)
Specifies the channel number for dialog settings. Each channel is configured
individually. The drop-down list illustrates the channels that currently have
measurements. There must be at least one displayed trace for the test set I/O
Interface to function.
Channel Control Label: (5)
Specifies the label to be displayed on the network analyzer screen during the
channel sweep.
Before Sweep Start – After Sweep End Tabs: (6)
Commands (GPIB, I/O and Dwell) can be sent Before Sweep Start and After
Sweep End. However, they are configured and enabled separately on the
Interface Control dialog box. For example; to send a command before and
after a network analyzer sweep, the Enable Interface Control check box must
be selected and commands entered in both the Before Sweep Start and After
Sweep End tabs. The Before Sweep Start data is sent before the first trace on
the channel begins sweeping. The After Sweep Start data is sent after the last
trace on the channel sweep is completed.
Dwell After Command: (7)
Specifies a wait time, in milliseconds, after all commands to all interfaces are
sent. Any positive integer is allowed. This is used to allow all external devices
to settle before beginning a measurement. An erratic trace could indicate that
more settling time is necessary.
Handler I/O Control and Aux I/O Output Voltage: (8)
Provides I/O interface control through the rear panel of the network analyzer.
Refer to the network analyzer Help menu for further information.
Reset All:
Sets all fields on all channels to their default values.
Save and Recall:
Saves and recalls the contents of the dialog box. If the Interface Control
dialog box is populated with settings during an Instrument State Save, the
settings are automatically recalled with the instrument state settings.
Interface control uses an *.xml file type. An example file is stored on the
network analyzer hard drive. You can recall it into the dialog, or you can open
and edit it with a word processor, such as Word Pad.