37/44
Scienlab Regenerative AC Emulator
–
Keysight SL1200A Series
–
Operating Instructions
Action in an Emergency 5
5
Action in an Emergency
In the event of an emergency, the system may only be switched on and recom-
missioned by specially trained personnel. (see
Qualification of the Operating Per-
In case of emergency, please carry out the described steps and inform the
local KeysightCare department:
Contact KeysightCare
Keysight Technologies Technical Support
www.keysight.com/find/keysightcare-contact
Control elements for switch-off
The following control elements are installed on the system for switching
off and shutting down the system in an emergency:
Emergency stop push button
•
On the front side
•
Press: forces local emergency stop of the system
(Responds: see safety relay)
•
Turn counter-clockwise: unlocks
Main switch
•
On the front side
•
I ON: power supply switched on
•
O OFF: power supply switched off, communication with the
system is maintained
•
Trip: when emergency stop is triggered → system switches
off, main switch in position Trip
•
Note: In the 0 OFF position, the main switch can be locked
using a padlock
Service switch/motor circuit breaker
•
Behind the front panel (detachable)
•
Fuse for the circuit (logic path) tapped upstream of the main
switch
•
O OFF: Circuit breaker has triggered → sys
tem is inactive; all
power and communication connections (logic path) are inac-
tive.
•
I ON: Logic path active, system can be activated via main
switch
NOTICE