System Requirements

Table 

10

  

External PC Requirements

General Information

Window 7 SP1 and Windows 10 (64-bit only)
Intel i5 6th generation or newer / Intel Xeon 3E v3 or newer
16 GB recommended; 4 GB minimum
2 GB available disk space minimum
1064 x 768 minimum
USB 3.0 port directly connected to Intel chipset

Operating System
Processor Speed
Available Memory
Available Disk Space
Display Resolution
USB

Table 1

1

  

Regulatory and Safety Compliance

Instrument Drivers

Keysight IO Libraries

IO Libraries Suite 2019 (18.1.24130.0) or later

EMC

Complies with the essential requirements of the European EMC 
Directive and the UK Electromagnetic Compatibility Regulations 
2016, as well as current editions of the following standards (dates 
and editions are cited in the Declaration of Conformity):

IEC/EN 61326-1

CISPR Pub 11, Group 1, class A

Caution: This equipment is not intended for use in residential 
environments and may not provide adequate protection to radio 
reception in such environments.

AS/NZS CISPR 11

CAN ICES/NMB-001(A)

This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.

Safety

Complies with the following standard (dates and editions are cited 
in the Declaration of Conformity):

IEC/EN 61010-1

Acoustic Statement: (European Machinery Directive)
Acoustic noise emission
LpA <70 dB
Operator position
Normal operation mode per ISO 7779

Temperature

For indoor use only.

46

Keysight P939xA Streamline Customs User's Guide

Summary of Contents for P939 A Series

Page 1: ...User s Guide Keysight Technologies P939xA USB Streamline Customs ...

Page 2: ...tware to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not requi...

Page 3: ...eral Characteristics 13 Block Diagram of P9391A Option OTX 14 Block Diagram of the P9391A Option OTX Combined Test Configuration 15 P9391A Option ORX 16 General Characteristics 16 Block Diagram of P9391A Option ORX 17 P9392A Option R53 18 General Characteristics 18 Block Diagram of P9392A Option R53 21 P9392A Option L53 22 General Characteristics 22 Block Diagram of P9392A Option L53 25 Instrument...

Page 4: ... are setup for independent standalone mode that don t require control Some option configurations can be controlled by an external computer allowing various functionalities such as monitoring or signal conditioning Description Congratulations on your purchase from Keysight Technologies P9390A 1 Slot USB Keysight Streamline Custom P9391A 2 Slot USB Keysight Streamline Custom P9392A 4 Slot USB Keysig...

Page 5: ...Keysight P939xA Streamline Customs User s Guide 5 Keysight P9392A Option R53 Remote OPE 10 MHz to 50 GHz Keysight P9392A Option L53 Local OPE 10 MHz to 50 GHz ...

Page 6: ... E Optical Receiver with 10 MHz to 50 GHz RF Amplifier Optical Transmitter Tx Receiver Rx with 10 MHz to 50 GHz RF Amplifier P9392A L53 R53 Local OPE 10 MHz to 50 GHz RF Dual O E Rx E O Tx and three RF Amplifiers Remote OPE 10 MHz to 50 GHz RF TR O E Rx Two E O Tx and three RF Amplifiers Rack Mount Kits Description Rack mount kit for 1 slot USB instruments Rack mount kit for 2 slot USB instruments...

Page 7: ...contains information and warnings that must be followed by the user to ensure safe operation and to maintain the product in a safe condition Only Keysight approved accessories shall be used To get the most out of your purchase it is recommended that this User s Guide be read carefully and completely Keysight P939xA Streamline Customs User s Guide 7 ...

Page 8: ...GHz 8 5 dBm 7 mW 1 RF Frequency Range Input Power 1 0 dB Compression Maximum RF Input Power Impedance RF Input Return Loss NF link loss with no amplification RF Connector Optical Connector Optical Wavelength Maximum Optical Transmission Distance Maximum Optical Power Out Laser Product Class Figure 1 Block Diagram of the P9390A Option OTX Optical Modulator RF IN Laser Modulator Assembly Optical Out...

Page 9: ...5 dBm 7 mW 1 RF Frequency Range Input Power 1 0 dB Compression Maximum RF Input Power Impedance RF Input Return Loss NF link loss with no amplification RF Connector Optical Connector Optical Wavelength Maximum Optical Transmission Distance Maximum Optical Power Out Laser Product Class Optical RX Module Specification 10 MHz to 50 GHz 50 Ohms 4 dB 2 4 mm female FC APC female 1550 nm 20 to 13 dBm 16 ...

Page 10: ...Optical Modulator RF IN Laser Modulator Assembly Optical Output Photodetector RF Out Optical Input Figure 2 Block Diagram of the P9390A Option OTR 10 Keysight P939xA Streamline Customs User s Guide ...

Page 11: ...F General Characteristics 10 MHz to 50 GHz 50 Ohms 4 dB 2 4 mm female FC APC female 1550 nm 20 to 13 dBm 16 dBm 40 mW RF Frequency Range Impedance RF Output Return Loss RF Connector Optical Connector Optical Wavelength Optical Average Input Power Range Optical Maximum Power In Figure 3 Block Diagram of the P9390A Option ORX Photodetector RF Out Optical Input Keysight P939xA Streamline Customs User...

Page 12: ...aracteristics 10 MHz to 50 GHz 50 Ohms 4 dB 2 4 mm female FC APC female 1550 nm 20 to 13 dBm 16 dBm 40 mW RF Frequency Range Impedance RF Output Return Loss RF Connectors Optical Connectors Optical Wavelength Optical Average Input Power Range Optical Maximum Power In Figure 4 Block Diagram of the P9390A Option ORR Photodetector RF Out Optical Input Photodetector RF Out Optical Input 12 Keysight P9...

Page 13: ... 8 5 dBm 7 mW 1 RF Frequency Range Input Power 1 0 dB Compression Maximum RF Input Power Impedance RF Input Return Loss NF link loss with no amplification RF Connector Optical Wavelength Maximum Optical Transmission Distance Maximum Optical Power Out Laser Product Class Amplifier Module Specification RF Frequency Range Input Power 0 1 dB Compression 10 MHz to 50 GHz Input Power 1 0 dB Compression ...

Page 14: ...cal Receiver and post M9405A Opt F50 Amplifier Output Power 1 dB Compression measured with M9403B Optical Receiver and post M9405A Opt F50 Amplifier Amplifier RF IN Amplifier RF Out Optical Modulator RF IN 25 Amplifier Laser Modulator Assembly Optical Output NF 1 GHz to 26 5 GHz 26 5 GHz to 50 GHz 7 dB 9 dB 10 MHz to 50 Ghz 25 dBm 10 dBm 16 dB 16 dB 15 dB Block Diagram of the P9391A Option OTX 14 ...

Page 15: ...s Amplifier RF IN Amplifier RF Out Optical Modulator RF IN 25 Amplifier Laser Modulator Assembly Optical Output Photodetector Amplifier RF IN Amplifer RF Out RF Out 25 Amplifier Optical Input Photodetector RF Out Optical Input Keysight P939xA Streamline Customs User s Guide 15 ...

Page 16: ...mW RF Frequency Range Impedance RF Output Return Loss RF Connector Optical Connector Optical Wavelength Optical Average Input Power Range Optical Maximum Power In Amplifier Module Specification RF Frequency Range Input Power 0 1 dB Compression 10 MHz to 50 GHz Input Power 1 0 dB Compression 10 MHz to 1 GHz 1 GHz to 50 GHz Maximum RF Input Power Gain 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz 10 MHz to ...

Page 17: ...Figure 7 Block Diagram of the P9391A Option ORX Photodetector Amplifier RF IN Amplifier RF Out RF Out 25 Amplifier Optical Input Keysight P939xA Streamline Customs User s Guide 17 ...

Page 18: ...on RF Input Power 1 0 dB Compression Maximum RF Input Power Impedance RF Input Return Loss NF link loss with no amplification RF Connector Optical Connector Optical Wavelength Maximum Optical Transmission Distance Maximum Optical Power Out Laser Product Class Slot 1 An OTX Optical Transmitter E O module has a built in RF 10 dB amplifier connected to the optical modulator input Slot 2 An OTR Optica...

Page 19: ...m 15 dBm 10 dBm 27 dB Typical 30 dB 24 dB Typical 27 dB 50 Ohms 10 dB 5 dB 7 dB 9 dB 2 4 mm female RF Frequency Range RF Input Power 0 1 dB Compression 10 MHz to 50 GHz RF Input Power 1 0 dB Compression 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz Maximum RF Input Power Gain 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz Impedance Return Loss RF Input Output 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz NF 1 GHz to 26 5 ...

Page 20: ...F Input to REF RCVR Out 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz Test Port to Test RCVR Out 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz R53 Shipped Configured with Jumper Cables Specifications 10 MHz to 50 GHz 30 dBm 28 dBm 25 dBm 27 dBm 6 dBm 10 dBm RF Frequency Range RF on Optical O E Input Power 0 1 dB Compression 10 MHz to 50 GHz 1 0 dB Compression 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz Maximum Test Por...

Page 21: ... RF Amp Input RF Amp Output O E Output O E Input SRC Out CPLR Thru Test Port Test CPLR Arm REF CPLR Arm SRC RF Input E O A Output 10 Amplifier Laser Modulator Assembly 10 Amplifier 25 Amplifier E O Input B E O Input A E O B Output REF CPLR Test CPLR Keysight P939xA Streamline Customs User s Guide 21 ...

Page 22: ...ers 26 5 GHz 1400 meters 50 GHz 8 5 dBm 7 mW 1 RF Frequency Range RF Input Power 0 1 dB Compression RF Input Power 1 0 dB Compression Maximum RF Input Power Impedance RF Input Return Loss NF link loss with no amplification RF Connector Optical Connector Optical Wavelength Maximum Optical Transmission Distance Maximum Optical Power Out Laser Product Class Slot 1 OTX Optical Transmitter E O module S...

Page 23: ...m 40 mW RF Frequency Range Impedance RF Output Return Loss RF Connectors Optical Connectors Optical Wavelength Optical Average Input Power Range Optical Maximum Power In Slot 4 Dual Amplifier Module Specifications 10 MHz to 50 GHz 22 dBm 18 dBm 15 dBm 10 dBm 27 dB Typical 30 dB 24 dB Typical 27 dB 50 Ohms 10 dB 5 dB RF Frequency Range Input Power 0 1 dB Compression 10 MHz to 50 GHz Input Power 1 0...

Page 24: ...fications 10 MHz to 50 GHz 32 dBm 28 dBm 28 dBm 23 dBm RF Frequency Range RF Amp Input C Input Power 0 1 dB Compression 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz 10 MHz to 26 5 GHz 26 5 GHz to 50 GHz 7 dB 9 dB 2 4 mm female 1 0 dB Compression 10 dBm Maximum RF Input Power 10 MHz to 50 GHz 24 Keysight P939xA Streamline Customs User s Guide ...

Page 25: ...O Output 25 Amplifier 25 Amplifier O E Input A 25 Amplifier RF Amp Input C RF Amp Output C E O Input O E Output A RF Amp Input A Test RCVR RF Amp Output A O E Output B RF Amp Input B REF RCVR RF Amp Output B O E Input B Keysight P939xA Streamline Customs User s Guide 25 ...

Page 26: ...ct Keysight Support at www keysight com find assist Use the following procedure to install the software 1 Launch the Keysight IO Libraries Suite installer and follow the prompts 2 Launch the Keysight M940x installer and follow the prompts 3 Restart the host PC 4 Save M940x_Setup 1 0 474 0 exe on the controller that will connect to your device Figure 10 5 Run the Windows InstallShield and follow th...

Page 27: ...Step 1 If you see the error message below install a newer version of the Keysight IO Libraries Suite Keysight P939xA Streamline Customs User s Guide 27 ...

Page 28: ...Step 2 Step 3 28 Keysight P939xA Streamline Customs User s Guide ...

Page 29: ...Step 4 Step 5 Keysight P939xA Streamline Customs User s Guide 29 ...

Page 30: ...amline Custom SFP App 6 When the InstallShield has finished running locate the Keysight P939x USB Streamline Custom folder in your file directory Figure 11 Click on P939x SFP or P939x SFP x64 Step 6 30 Keysight P939xA Streamline Customs User s Guide ...

Page 31: ...eysight Connection Expert application The P9391A shows up as Chassis 5 with model number P6002A Each chassis has its own unique serial number Slot information shows that the P9391A has two slots Each slot has its own SFP and can only be accessed through the Keysight P939x USB Streamline Custom P939x SFP application located under the Front Panel Windows icon see Figure 12 If your system has more th...

Page 32: ...nection In this example Figure 14 we have the instrument connected directly to a PC as indicated by Chassis 1 The instrument indicates two slots and each slot has an independent SFP Select the slot SFP and press the Connect button P9391A Option Slot Information OTX Slot 1 Optical Laser Modulator Slot 2 RF Amplifier ORX Slot 1 Optical Detector Slot 2 RF Amplifier 32 Keysight P939xA Streamline Custo...

Page 33: ... quadrature point The quadrature point establishes the modulation format For the P939xA the analog modulation format is chosen Environmental and internal temperature changes can cause the quadrature point to drift over time Initially when the P939xA optical transmitter is turned on the instrument goes through a temperature stabilization and self calibration before the quadrature point is recognize...

Page 34: ...performance output This can be seen in changes in magnitude of several dB with changes of 1 degree C 2 If stabilization has not occurred after ten minutes the unit will tune to a quadrature set point 3 It s recommended that after a thirty minute warm up another Modulator Calibrate be done 4 Measurements should only be made after the unit has had enough time to warm up and has stabilized A daily Mo...

Page 35: ...ely Bias Locked indicates the laser and optical modulator has tuned for optimal RF performance Bias Unlocked condition can happen if exceeding RF power for locked state The Rx Interrupt Detection resets the status of the Rx Fault No Fault Once a Fault has been detected the status must be reset once the connection has been reestablished Resetting the power will also reset the Fault status P939xA OT...

Page 36: ...le internal diagnosis Rx indicates No Fault Fault monitoring optical connection RX Fault indicates the fiber connection has been temporarily broken or lost completely The Rx Interrupt Detection resets the status of the Rx Fault No Fault Once a Fault has been detected the status must be reset once the connection has been reestablished Resetting the power will also reset the Fault status P939xA ORX ...

Page 37: ... Self Test can be run to diagnose module issues Status will indicate Good if no problems are found P939xA Soft Front Panel Amplifier Module Figure 19 Utilities Menu The utilities menu allows the user to check the status of the module and load new firmware when available Keysight P939xA Streamline Customs User s Guide 37 ...

Page 38: ...Figure 20 Self Test A diagnostic test that checks the modules internal power supply status 38 Keysight P939xA Streamline Customs User s Guide ...

Page 39: ...r Firmware Scroll down until you see CARRIER Firmware The current carrier firmware for each slot can be found in the Soft Front Panel under the Help tab and selecting About Figure 21 Keysight P939xA Streamline Customs User s Guide 39 ...

Page 40: ...r R53 Slot 1 Optical Transmitter Slot 2 Optical Transmitter Receiver Slot 3 Amplifier Slot 4 Dual Reflectometer 1 5 1 2 2018 03 21 17 00 00 1 5 1 5 2021 05 25 15 00 00 1 5 1 5 2021 05 25 15 00 00 1 5 1 2 2018 03 21 17 00 00 1 5 0 7 2021 04 13 10 00 00 1 5 1 5 2021 05 25 15 00 00 1 5 0 7 2021 04 13 10 00 00 1 5 1 5 2021 05 25 15 00 00 1 5 0 7 2021 04 13 10 00 00 1 5 1 2 2018 03 21 17 00 00 1 5 0 7 ...

Page 41: ...Figure 22 Keysight Connection Expert P9390A P9391A Keysight P939xA Streamline Customs User s Guide 41 ...

Page 42: ...t B Test Port Connect To PNA Test Port 2 RF Amp Input C Connect To PNA Test Port 1 Source X Input DUT RF Amp Output B Connect To PNA Test Port 4 Reference X RCVR Input RF Amp Output A Connect To PNA Test Port 3 Test X RCVR Input 20 dBm 30 to 55 dBm 4 dBm 4 to 2 dBm 32 dBm 30 to 45 dBm 4 to 17 dBm 2 to 22 dBm 10 dBm 12 to 34 dBm 6 dBm 30 to 55 dBm 20 dBm P9392A Option R53 P9392A Option L53 Notes Re...

Page 43: ...Link Loss with No Amplification RF IN RF OUT 1550nm Laser Diode 1530 1610 nm Modulator 1480 1620 nm Photodetector Optical Link E O O E Optical OUT Optical IN Option 702 Standard Keysight P939xA Streamline Customs User s Guide 43 ...

Page 44: ...sion with RF Amplification after Optical Rx Plot taken using P9391A Option OTX and P9391A Option ORX Figure 25 Typical RF Amplifier Gain Plot taken using P9391A Option OTX and P9391A Option ORX 44 Keysight P939xA Streamline Customs User s Guide ...

Page 45: ...ure 27 Typical Optical Link Loss Conversion with RF Amplification before Optical Tx and after RX Plot taken using P9391A Option OTX and P9391A Option ORX Keysight P939xA Streamline Customs User s Guide 45 ...

Page 46: ...ic Compatibility Regulations 2016 as well as current editions of the following standards dates and editions are cited in the Declaration of Conformity IEC EN 61326 1 CISPR Pub 11 Group 1 class A Caution This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments AS NZS CISPR 11 CAN ICES NMB 001 A This ISM device...

Page 47: ...eet Up to 4 572 meters 15 000 feet Operating Non operating Instrument Protection Warm up Time IP 30 IEC EN 60529 60 minutes To find a current Declaration of Conformity for a specific Keysight product go to http www keysight com go conformity Keysight P939xA Streamline Customs User s Guide 47 ...

Page 48: ...g connectors with alcohol shall only be done with the instruments power cord removed and in a well ventilated area Allow all residual alcohol moisture to evaporate and the fumes to dissipate prior to energizing the instrument This product is designed for use in Installation Category II and Pollution Degree 2 Install the instrument so that the detachable power cord is readily identifiable and is ea...

Page 49: ...upply voltage fluctuations up to 10 of the nominal voltage The mains wiring and connectors shall be compatible with the connector used in the premise electrical system Failure to ensure adequate earth grounding by not using the correct components may cause product damage and serious injury The input terminals for this product are classified as Measurement Category None Keysight P939xA Streamline C...

Page 50: ...ll The Keysight email address is required by EU directives applicable to our product The CSA mark is a registered trademark of the CSA International This is a symbol of an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 5 This is a marking to indicate product compliance with the Industry Canada Interference Causing Equipment Standard ICES 001 Cet appareil ISM est conforme...

Page 51: ...tion Table 14 Front Panel Information RF Connector Types Impedance Optical Connector Type Optical Wavelength Maximum Optical Power Out Maximum Optical Input Power Laser Product Class 2 4 mm female nominal 50 Ohm 3 5 mm female nominal 50 Ohm 50 Ohm FCAPC 1550 nm 8 5 dBm 7 mW 16 dBm 40 mW 1 Description Table 15 Rear Panel Information USB Ports Power Connector 10 MHz In SMB 10 MHz Out SMB Trig 1 Trig...

Page 52: ... with NI I O software Free software download at www keysight com find iosuite Description Information Keysight IO Library The USB Customs includes a soft front panel SFP a software based graphical user interface GUI which enables the instrument s capabilities from your PC Keysight Soft Front Panel Assists in finding the right instrument commands and setting correct parameters A simple interface in...

Page 53: ...ght representative can determine whether your unit is still within its warranty period To verify the contents shipped with your product refer to the Box Content List included with the shipment Inspect the shipping container If the container or packing material is damaged it should be kept until the contents of the shipment have been checked mechanically and electrically If there is any physical da...

Page 54: ...This information is subject to change without notice Keysight Technologies 2020 2021 Edition 5 August 2021 Supersedes June 2021 www keysight com ...

Reviews: