94
Chapter 4
Dynamic Sequencing Option 300
Dynamic Sequencing
Dynamic Sequencing
Dynamic sequencing is a mode where the AWG scenario handle memory is
bypassed and scenarios are selectedfrom an external source. You must first
load the data into the N8241A LXI-AWG memory, then, in real-time,
provide the scenario handles through the AUX PORT input connector.
NOTE
The dynamic sequencing option is only available through the programmatic
interfaces since it operates in the advanced sequencing mode that is not
available through the Control Utility. Refer to
.
Figure 4-1
Dynamic Sequencing Block Diagram
AUX PORT Connector
Description:
Receptacle, Mini D
Number of Contacts: 20
Manufacturer:
3M
Part Number:
10220-0210EC