M9506A-BC1 5-Slot AXIe Chassis with Integrated Controller User Guide
65
SCPI Programming Interface
4
Query
:DIGitizer[N]:TRIGger:INPut:SLOPe?
Description
This query returns the current setting for channel trigger slope, [RISing, FALLing]
std_string.
Example
-> dig3:trig:inp:slop?
<- RIS
:DIGitizer[N]:TRIGger:FORCe
Command
:DIGitizer[N]:TRIGger:FORCe
Description
This command sends a software trigger to the specific digitizer.
Example
-> dig3:trig:forc
:DIGitizer[N]:ARM
Command
:DIGitizer[N]:ARM
Description
This command arms a single module in the chassis for acquisition.
Example
-> dig3:arm
:DIGitizer[N]:UNARM
Command
:DIGitizer[N]:UNARM
Description
This command dis-arms a single module in a chassis for acquisition.
Example
-> dig3:unarm
:ARM
Command
:ARM
Description
This command arms all modules in chassis for acquisition.
All modules need to be configured and self-calibrated.
Example
-> arm
Summary of Contents for M9506A-BC1
Page 1: ...Keysight M9506A BC1 5 Slot AXIe Chassis with Integrated Controller User Guide...
Page 22: ......
Page 42: ......
Page 94: ......