Keysight Technologies M9393A Configuration Manual Download Page 8

08 | Keysight | M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8.4 GHz, 14 GHz, 18 GHz or 27 GHz - Configuration Guide

Step 1. Start with M9393A base configuration 

The M9393A comes standard with the following software:

 

Keysight IO Libraries Suite including Connection Expert

1

 

Instrument software, soft front panel, drivers for use with MATLAB, LabVIEW, Visual Studio (including VB Net, C#, C/C++), Keysight VEE 

2

 

Sample waveforms and programming examples

Step 2. Download free Keysight Command Expert software 

3

 (optional)

FREE software that provides fast and easy instrument control for the PC. Command Expert combines instrument command sets, command 
sequences, documentation, syntax checking and command execution in one simple interface. Command Expert helps you to:

 

Find instrument commands

 

Access command documentation

 

Verify command syntax

 

Build instrument command sequences

 

Execute instrument command sequences

 

Integrate sequences in MATLAB, Visual Studio, Excel, LabVIEW, Keysight VEE or Keysight SystemVue PC application environment

 

Generate code for command sequences in MATLAB, Visual C#, Visual Basic.NET and Visual C/C++

 

Profile command execution time

 

Debug command sequences using breakpoints and single stepping

Step 3. Add X-Series Measurement Applications for Modular Instruments 

4

 (optional)

Provides essential RF conformance measurements and tasks for specific communications standards.  
Transportable, perpetual licenses support up to 4 modular VSAs in one chassis.

M9080A/B

LTE FDD, LTE-Advanced FDD

M9082A/B

LTE TDD, LTE-Advanced TDD

M9073A

W-CDMA/HSPA+

M9071A

GSM/EDGE/EVO

M9079A

TD-SCDMA/HSPA

M9076A

1xEV-D0

M9072A

cdma2000

®

/cdmaOne

M9077A

WLAN 802.11a/b/g/n/ac

M9063A

Analog modulation

M9064A

VXA vector signal analysis

M9081A

Bluetooth

®

E. Select software for M9393A PXIe performance VSA

1. 

Both IO library (version 16.3 or newer) and Connection Expert software need to be installed on the PC controlling the equipment. To download, visit 

 

www.keysight.com/find/iosuite

2. 

Find latest versions of this software at www.keysight.com/find/m9393a

3. 

To download or get more information on Command Expert, visit www.keysight.com/find/commandexpert

 

4. 

For more information, see “Accelerate PXI VSA Measurements with X-Series Measurement Applications”, literature number

 

5991-2604EN

.

Summary of Contents for M9393A

Page 1: ...Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide...

Page 2: ...ect services Warranty calibration start up assistance 10 Multiple M9393A PXIe performance VSAs in a single chassis 10 Configuration Single M9393A PXIe performance VSA 11 Single PXIe performance VSA M9...

Page 3: ...s bandwidth M9393A B04 40 MHz Included in base configuration M9393A B10 100 MHz M9393A B16 160 MHz Step 4 Choose memory size M9393A M01 128 MSa Included in base configuration M9393A M05 512 MSa M9393A...

Page 4: ...the PC from the PXIe chassis Features removable SSD drive for security and x8 connector from front for connection to second chassis Step 2 Upgrade from standard memory size optional For M9036A M9036A...

Page 5: ...pressCard adaptor Y1200B PCIe cable M9021A PCIe cable interface1 1 slot To use your Desktop PC as a controller M9048A PCIe desktop adaptor Y1202A PCIe cable M9021A PCIe cable interface1 1 slot C Selec...

Page 6: ...212A Slot blocker kit 5 slots Y1213A PXI EMC filler panel kit 5 slots Step 3 Choose a rack mount kit optional Y1215A Rack mount kit for M9018A 18 slot PXIe chassis Step 4 Choose an air inlet kit optio...

Page 7: ...07 Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide Physical Connections Physical connection diagram for controllers...

Page 8: ...ate code for command sequences in MATLAB Visual C Visual Basic NET and Visual C C Profile command execution time Debug command sequences using breakpoints and single stepping Step 3 Add X Series Measu...

Page 9: ...ypes of presets 89601B BHF Custom OFDM modulation analysis of propriety and pre standard OFDM formats 89601B B7R WLAN 802 11a b g j p 89601B B7Z WLAN 802 11n MIMO 89601B BHJ WLAN 802 11ac MIMO require...

Page 10: ...grades the global warranty to provide 5 day typical turnaround repair service in the US Japan China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world Prio...

Page 11: ...e for detailed cabling diagram and parts list Additional cables shipped One 8121 2063 BNC Male SMB Female 1200mm for external reference connection One 8120 5091 SMB Female SMB Female 120mm for shorter...

Page 12: ...our M9393As in a single M9018A chassis Multiple PXIe performance VSAs in a single PXIe chassis It is recommended that you install the M9393A modules entirely in consecutive slots beginning with slot 2...

Page 13: ...ght chassis The M9393A with M9300A frequency reference can be successfully installed in a non Keysight PXI chassis Please use the following guidelines Ensure that the chassis has 5 consecutive PXIe or...

Page 14: ...isted countries www keysight com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality...

Reviews: