10 | Keysight | M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8.4 GHz, 14 GHz, 18 GHz or 27 GHz - Configuration Guide

One day start-up assistance

Included in base configuration

M9393A-UK6

Commercial calibration certificate with test data for 
M9393A (M9308A, M9365A, M9214A)

Calibration certificate with measurement results available only at 
time of purchase.

M9300A-UK6

Commercial calibration certificate with test data for 

M9300A

Calibration certificate with measurement results available only at 
time of purchase.

N7800A Calibration and adjustment software

F. Select services: Calibration, start-up assistance

Global warranty

Keysight Technologies, Inc. provides the peace of mind that today’s high tech industry 

 

requires. Your investment is protected by Keysight’s global reach in more than 100 

 

countries (either directly or through distributors). The warranty gives you convenient 

 

standard coverage for the country in which the product is used, eliminating the need to 
ship equipment back to the country of purchase. Keysight’s warranty service provides:

 

All parts and labor necessary to return your investment to full specified performance

 

Recalibration for products supplied originally with a calibration certificate

 

Return shipment

Express warranty

Reduce downtime with the fastest repair service in the industry.  The express warranty 
upgrades the global warranty to provide:

 

 5 day typical turnaround repair service in the US, Japan, China and many EU 

 

countries or up to a 10 day improvement in turnaround time in the rest of the world

 

Priority return shipment

One day start-up assistance

A Keysight Technologies applications engineer will get you started quickly by helping you 
install the modules in a chassis, configure the controller, load software and start making 
measurements.

Calibration services

The modular products are factory calibrated and shipped with an ISO-9002, 

 

NIST-traceable calibration certificate. A one year calibration cycle is recommended. The 
M9393A PXIe performance VSA is supported by the Keysight N7800A calibration 

 

software to perform calibrations that test all product specifications and is compliant with 
ISO 17025:2005, ANSI/NCSL Z540.3-2006 and measurement uncertainty per ISO Guide to 
Expression of Measurement Uncertainty 1995.

N7800A calibration & adjustment software

The M9393A PXIe performance VSA is supported by Keysight’s calibration and 

 

adjustment software. This is the same software used at Keysight’s service centers to 
automate calibration. The software offers compliance tests for ISO 17025:2005, 

 

ANSI/NCSL Z540.3-2006, and measurement uncertainty per ISO Guide to Expression of 
Measurement Uncertainty.

Product Information:  

www.keysight.com/find/contactus

Or call:  1 800 829-4444 US

Repair and Calibration:  

www.keysight.com/find/infoline

Parts and Accessories:  

www.parts.keysight.com

For all modular products:  

www.keysight.com/find/modular

Summary of Contents for M9393A

Page 1: ...Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide...

Page 2: ...ect services Warranty calibration start up assistance 10 Multiple M9393A PXIe performance VSAs in a single chassis 10 Configuration Single M9393A PXIe performance VSA 11 Single PXIe performance VSA M9...

Page 3: ...s bandwidth M9393A B04 40 MHz Included in base configuration M9393A B10 100 MHz M9393A B16 160 MHz Step 4 Choose memory size M9393A M01 128 MSa Included in base configuration M9393A M05 512 MSa M9393A...

Page 4: ...the PC from the PXIe chassis Features removable SSD drive for security and x8 connector from front for connection to second chassis Step 2 Upgrade from standard memory size optional For M9036A M9036A...

Page 5: ...pressCard adaptor Y1200B PCIe cable M9021A PCIe cable interface1 1 slot To use your Desktop PC as a controller M9048A PCIe desktop adaptor Y1202A PCIe cable M9021A PCIe cable interface1 1 slot C Selec...

Page 6: ...212A Slot blocker kit 5 slots Y1213A PXI EMC filler panel kit 5 slots Step 3 Choose a rack mount kit optional Y1215A Rack mount kit for M9018A 18 slot PXIe chassis Step 4 Choose an air inlet kit optio...

Page 7: ...07 Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide Physical Connections Physical connection diagram for controllers...

Page 8: ...ate code for command sequences in MATLAB Visual C Visual Basic NET and Visual C C Profile command execution time Debug command sequences using breakpoints and single stepping Step 3 Add X Series Measu...

Page 9: ...ypes of presets 89601B BHF Custom OFDM modulation analysis of propriety and pre standard OFDM formats 89601B B7R WLAN 802 11a b g j p 89601B B7Z WLAN 802 11n MIMO 89601B BHJ WLAN 802 11ac MIMO require...

Page 10: ...grades the global warranty to provide 5 day typical turnaround repair service in the US Japan China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world Prio...

Page 11: ...e for detailed cabling diagram and parts list Additional cables shipped One 8121 2063 BNC Male SMB Female 1200mm for external reference connection One 8120 5091 SMB Female SMB Female 120mm for shorter...

Page 12: ...our M9393As in a single M9018A chassis Multiple PXIe performance VSAs in a single PXIe chassis It is recommended that you install the M9393A modules entirely in consecutive slots beginning with slot 2...

Page 13: ...ght chassis The M9393A with M9300A frequency reference can be successfully installed in a non Keysight PXI chassis Please use the following guidelines Ensure that the chassis has 5 consecutive PXIe or...

Page 14: ...isted countries www keysight com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality...

Reviews: