![Keysight Technologies M9393A Configuration Manual Download Page 13](http://html1.mh-extra.com/html/keysight-technologies/m9393a/m9393a_configuration-manual_1962009013.webp)
13 | Keysight | M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8.4 GHz, 14 GHz, 18 GHz or 27 GHz - Configuration Guide
Windows 7
Operating system
Windows 7 (32 & 64 bit)
Processor speed
1.5 GHz dual core (x86 or x64) minimum,
2.4 GHz recommended
No support for Itanium64
Available memory
4 GB minimum
8 GB recommended
Available disk space
1
1.5 GB available hard disk space includes:
1 GB for Microsoft.NET framework 4.0
100 MB for Keysight IO libraries suite
Video
Support for DirectX 9 graphics with 128 MB graphics recommended (SuperVGA supported)
Browser
Microsoft Internet Explorer 7.0 or greater
PC requirements for M9393A PXIe performance VSA control
1
Related literature
For more detailed product and specification information refer to the following literature and web pages:
–
M9018A PXIe 18 slot Chassis Data Sheet (literature no.
–
M9037A PXIe High Performance Embedded Controller Data Sheet (literature no.
–
M9036A PXIe Embedded Controller Data Sheet (literature no.
–
X-Series Measurement Applications for Modular Instruments Brochure (literature no.
)
Using a non-Keysight chassis
The M9393A (with M9300A frequency reference) can be successfully installed in a
non-Keysight PXI chassis. Please use the
following guidelines.
–
Ensure that the chassis has 5 consecutive PXIe or PXI-H slots which can be used by
the M9393A and M9300A.
–
Ensure that the chassis and controller supports peer-to-peer PXI Express I/O switch
topology.
–
Ensure that controller selected is compatible with chassis.
Please contact your Keysight representative for more detailed information. For technical
assistance with non-Keysight equipment, please refer to the equipment manufacturer’s
website.
Upgrading your system
Your product can be easily upgraded after the initial purchase. All PXIe VSA options are
controlled by a licensing key and can be quickly upgraded by the user.
How to upgrade your M9393A PXIe performance VSA:
1.
Contact your Keysight representative to place an order for an option upgrade.
2.
You will receive your hardware entitlement certificate via email.
3.
Redeem the certificate online by following the instructions provided to receive a
license key file.
4.
Install the license key file using the Keysight License Manager.
5.
Begin using the new capability.
1.