1 Installing the PXI Chassis Hardware

Keysight

 

M9347A

H02

 

Getting

 

Started

 

Guide

1

1 Installing the PXI Chassis Hardware

The PXI System consists of the following items:

M9037A

 

PXIe

 

High

 

Performance

 

Embedded

 

Controller

 (or an appropriate 

external controller; see 

supported 

list at 

https://www.keysight.com/ca/en/

assets/7018-02925/technical-overviews/5990-7632.pdf

)

M9019A 

PXI

 

Chassis

 

M9347

A

 Module

Keysight

 

M9347

A

 

software

The installation procedure in this chapter will lead you through setting up the
hardware. After that is complete, you will refer to

2 Installing the Graphical User

Interface Softpanel (page 5)

.

This installation procedure will lead you through a series of steps to set up your PLTS
hardware. The following is a list of the installation steps:

Step

 

1.

 

Verify

 

your

 

System

 

Shipment

Step

 

2.

 

Set

 

Up

 

the

 

PXI

 

Chassis

Step

 

3.

 

Insert

 

the

 

M9347

A

 

into

 

the

 

PXI

 

Chassis

Step

 

4.

 

Power

 

up

 

the

 

Chassis

Step

 

5.

 

Install

 

the

 

M9347

A

 

Software

 

on

 

the

 

PXIe

 

Controller

Verify your System Shipment

1. Unpack your system from the containers in which it was shipped.

Summary of Contents for M9347AH02

Page 1: ...Getting Started Guide Keysight M9347AH02 Direct Digital Synthesizer...

Page 2: ...ms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End...

Page 3: ...ith local AC mains connections Assume all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user documentation Exercise...

Page 4: ...ompliance with the Canadian Interference Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 South Kore...

Page 5: ...llation 5 Starting the Software 7 Clock Selection 8 Reference Out 8 Setting the Synthesizers 9 Troubleshooting 10 3 M9347A SCPI Command Reference 11 Introduction 11 DDS Subsystem 11 Frequency DDS 1 2...

Page 6: ...stallation procedure in this chapter will lead you through setting up the hardware After that is complete you will refer to 2 Installing the Graphical User Interface Softpanel page 5 This installation...

Page 7: ...re that it was not damaged during shipment If your system was damaged during shipment contact Keysight Technologies Refer to Contacting Keysight page 3 If an instrument handle is damaged you should re...

Page 8: ...ds and the chassis Ventilation Requirements When installing the product in a cabinet the convection into and out of the product must not be restricted The ambient temperature outside the cabinet must...

Page 9: ...eer Make sure have the following information readily available the serial number of the test set a list of any options or accessories installed in or in use with the test set any information you can s...

Page 10: ...e Graphical User Interface Softpanel Installation Run the M9347A Setup file Select Yes to trust the Keysight installer The InstallShield Wizard should pop up on your computer screen Click Next Read th...

Page 11: ...setup type and click Next Click Install The software will take some time to install You will need to restart your computer before you can use the program Once the restart is complete the software is i...

Page 12: ...Keysight M9347AH02 Getting Started Guide 7 Starting the Software Search for the M9347A program on your computer and run the application x64 version if your computer is able The following screen shoul...

Page 13: ...s Do not change any DDS settings before the clock alignment as this could produce inaccurate signals 8 Keysight M9347AH02 Getting Started Guide The M9347A H02 module needs a 100 MHz clock signal to al...

Page 14: ...zers control boxes DDS 1 and DDS 2 Frequency 1MHz to 20GHz with a resolution of 1mHz Power Range 0 to to 12dBm up to 13GHz and 5 dBm 20GHz with a resolution of 1dB Phase Resolution 0 0054 degrees Refe...

Page 15: ...Self Test located in Utilities Self Test For the latest driver and firmware software contact your local Applications Engineer or visit http www keysight com find contactus The Self Test Dialog Box wi...

Page 16: ...two direct digital synthesizer channels Each channel is independently controllable Frequency DDS 1 2 DDS 1 2 FREQuency val unit DDS 1 2 FREQuency MAXimum MINimum This command sets the RF output freque...

Page 17: ...zers 2 PhaseOffset 45 0 Output Enabled DDS 1 2 DDS 1 2 OUTPut STATe ON OFF 1 0 DDS 1 2 OUTPut STATe This command enables or disables the RF output of the synthesizer Example DDS2 OUTP OFF The precedin...

Page 18: ...clock A direct clock from 17 20 0 GHz a direct clock at 4 8 GHz or a 100 MHz reference clock The direct clock must be provided at the Clock In port of the front panel and the 100 MHz must be provided...

Page 19: ...nce Example CLK OUT REFOUT4800MHZ The preceding example sets the reference output frequency to 4 8 GHz IVI Equivalent KtM9347 Clock ReferenceOutFrequency RefOutFrequency RefOut4800MHz 14 Keysight M934...

Page 20: ...This information is subject to change without notice Keysight Technologies 2013 2020 Edition 2 September 2020 Supersedes February 2018 Printed In USA M9347 90001 www keysight com...

Reviews: