background image

Notices

Copyright

 

Notice

©

 

Keysight

 

Technologies

 

2013

 

-

 

20

20

No

 

part

 

of

 

this

 

manual

 

may

 

be

 

reproduced

 

in

 

any

 

form

 

or

 

by

 

any

 

means

 

(including

 

electronic

 

storage

 

and

 

retrieval

 

or

 

translation

 

into

 

a

 

foreign

 

language

 

without

 

prior

 

agreement

 

and

 

written

 

consent

 

from

 

Keysight

 

Technologies,

 

Inc.

 

as

 

governed

 

by

 

United

 

States

 

and

 

international

 

copyright

 

laws.

Manual

 

Part

 

Number

M9347

-90001

Published

 

By

Keysight

 

Technologies

1400

 

Fountaingrove

 

Parkway

Santa

 

Rosa

CA

 

95405

Edition

Edition

 

2

,

 

September

 2020

 

Supersedes: 

February

 

2018

Printed

 

In

 

USA

Regulatory

 

Compliance

This

 

product

 

has

 

been

 

designed

 

and

 

tested

 

in

 

accordance

 

with

 

accepted

 

industry

 

standards,

 

and

 

has

 

been

 

supplied

 

in

 

a

 

safe

 

condition.

 

To

 

review

 

the

 

Declaration

 

of

 

Conformity,

 

go

 

to

 

http://www.keysight.com/go/conformity

.

Warranty

THE

 

MATERIAL

 

CONTAINED

 

IN

 

THIS

 

DOCUMENT

 

IS

 

PROVIDED

 

“AS

 

IS,”

 

AND

 

IS

 

SUBJECT

 

TO

 

BEING

 

CHANGED,

 

WITHOUT

 

NOTICE,

 

IN

 

FUTURE

 

EDITIONS.

 

FURTHER,

 

TO

 

THE

 

MAXIMUM

 

EXTENT

 

PERMITTED

 

BY

 

APPLICABLE

 

LAW,

 

KEYSIGHT

 

DISCLAIMS

 

ALL

 

WARRANTIES,

 

EITHER

 

EXPRESS

 

OR

 

IMPLIED,

 

WITH

 

REGARD

 

TO

 

THIS

 

MANUAL

 

AND

 

ANY

 

INFORMATION

 

CONTAINED

 

HEREIN,

 

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

THE

 

IMPLIED

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

AND

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE.

 

KEYSIGHT

 

SHALL

 

NOT

 

BE

 

LIABLE

 

FOR

 

ERRORS

 

OR

 

FOR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

 

IN

 

CONNECTION

 

WITH

 

THE

FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE
USER HAVE A SEPARATE WRITTEN
AGREEMENT WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.

KEYSIGHT TECHNOLOGIES DOES NOT
WARRANT THIRD-PARTY SYSTEM-
LEVEL (COMBINATION OF CHASSIS,
CONTROLLERS, MODULES, ETC.)
PERFORMANCE, SAFETY, OR
REGULATORY COMPLIANCE, UNLESS
SPECIFICALLY STATED.

Technology Licenses

The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance with
the terms of such license.

U.S. Government Rights

The Software is “commercial computer
software,” as defined by Federal
Acquisition Regulation (“FAR”) 2.101.
Pursuant to FAR 12.212 and 27.405-3
and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the
U.S. government acquires commercial
computer software under the same
terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User
License Agreement (EULA), a copy of
which can be found at

http://www.keysight.com/find/sweula

. The

license set forth in the EULA represents
the exclusive authority by which the
U.S. government may use, modify,
distribute, or disclose the Software. The
EULA and the license set forth therein,
does not require or permit, among other
things, that Keysight: (1) Furnish
technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish

to, or otherwise provide, the
government rights in excess of these
rights customarily provided to the
public to use, modify, reproduce,
release, perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional
government requirements beyond
those set forth in the EULA shall apply,
except to the extent that those terms,
rights, or licenses are explicitly required
from all providers of commercial
computer software pursuant to the FAR
and the DFARS and are set forth
specifically in writing elsewhere in the
EULA. Keysight shall be under no
obligation to update, revise or otherwise
modify the Software. With respect to
any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the U.S.
government acquires no greater than
Limited Rights as defined in FAR 27.401
or DFAR 227.7103-5 (c), as applicable in
any technical data.

Safety Notices

A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.

A WARNING notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.

The following safety precautions should
be observed before using this product
and any associated instrumentation.

This product is intended for use by
qualified personnel who recognize

ii

Summary of Contents for M9347AH02

Page 1: ...Getting Started Guide Keysight M9347AH02 Direct Digital Synthesizer...

Page 2: ...ms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End...

Page 3: ...ith local AC mains connections Assume all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user documentation Exercise...

Page 4: ...ompliance with the Canadian Interference Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 South Kore...

Page 5: ...llation 5 Starting the Software 7 Clock Selection 8 Reference Out 8 Setting the Synthesizers 9 Troubleshooting 10 3 M9347A SCPI Command Reference 11 Introduction 11 DDS Subsystem 11 Frequency DDS 1 2...

Page 6: ...stallation procedure in this chapter will lead you through setting up the hardware After that is complete you will refer to 2 Installing the Graphical User Interface Softpanel page 5 This installation...

Page 7: ...re that it was not damaged during shipment If your system was damaged during shipment contact Keysight Technologies Refer to Contacting Keysight page 3 If an instrument handle is damaged you should re...

Page 8: ...ds and the chassis Ventilation Requirements When installing the product in a cabinet the convection into and out of the product must not be restricted The ambient temperature outside the cabinet must...

Page 9: ...eer Make sure have the following information readily available the serial number of the test set a list of any options or accessories installed in or in use with the test set any information you can s...

Page 10: ...e Graphical User Interface Softpanel Installation Run the M9347A Setup file Select Yes to trust the Keysight installer The InstallShield Wizard should pop up on your computer screen Click Next Read th...

Page 11: ...setup type and click Next Click Install The software will take some time to install You will need to restart your computer before you can use the program Once the restart is complete the software is i...

Page 12: ...Keysight M9347AH02 Getting Started Guide 7 Starting the Software Search for the M9347A program on your computer and run the application x64 version if your computer is able The following screen shoul...

Page 13: ...s Do not change any DDS settings before the clock alignment as this could produce inaccurate signals 8 Keysight M9347AH02 Getting Started Guide The M9347A H02 module needs a 100 MHz clock signal to al...

Page 14: ...zers control boxes DDS 1 and DDS 2 Frequency 1MHz to 20GHz with a resolution of 1mHz Power Range 0 to to 12dBm up to 13GHz and 5 dBm 20GHz with a resolution of 1dB Phase Resolution 0 0054 degrees Refe...

Page 15: ...Self Test located in Utilities Self Test For the latest driver and firmware software contact your local Applications Engineer or visit http www keysight com find contactus The Self Test Dialog Box wi...

Page 16: ...two direct digital synthesizer channels Each channel is independently controllable Frequency DDS 1 2 DDS 1 2 FREQuency val unit DDS 1 2 FREQuency MAXimum MINimum This command sets the RF output freque...

Page 17: ...zers 2 PhaseOffset 45 0 Output Enabled DDS 1 2 DDS 1 2 OUTPut STATe ON OFF 1 0 DDS 1 2 OUTPut STATe This command enables or disables the RF output of the synthesizer Example DDS2 OUTP OFF The precedin...

Page 18: ...clock A direct clock from 17 20 0 GHz a direct clock at 4 8 GHz or a 100 MHz reference clock The direct clock must be provided at the Clock In port of the front panel and the 100 MHz must be provided...

Page 19: ...nce Example CLK OUT REFOUT4800MHZ The preceding example sets the reference output frequency to 4 8 GHz IVI Equivalent KtM9347 Clock ReferenceOutFrequency RefOutFrequency RefOut4800MHz 14 Keysight M934...

Page 20: ...This information is subject to change without notice Keysight Technologies 2013 2020 Edition 2 September 2020 Supersedes February 2018 Printed In USA M9347 90001 www keysight com...

Reviews: