Keysight Technologies M9035A Startup Manual Download Page 27

Keysight M9035A PXIe Embedded Controller Startup Guide

27

Controller Operating System

Controller Operating System

Your M9035A comes with the Microsoft Windows operating system pre-installed 
along with the latest version of Keysight's IO Libraries Suite. This section provides 
some general system configuration and preventative maintenance procedures 
that you, the customer, are responsible for. In general, the M9035A operates as 
any other PC, including remote desktop access.

The Windows operating system supplied with your M9035A is licensed for use on 
the hard drive mounted to the controller. If the hard drive is replaced, it may be 
your responsibility to purchase or relicense the operating system.

M9018 PXIe Chassis PCIe Link Configuration

This discussion is applicable when using the M9035A in an M9018A or M9018B 
PXIe Chassis. It does not apply for use with the M9019A or M9010A PXIe chassis, 
because they have a fixed configuration of 1x8 and 1x16 for their PCIe Link fabric.

PCIe link configuration

 refers to how the PXIe chassis PCIe Switch Fabric is 

configured to connect PCI Express signals between slot 1, the system controller 
slot, and the other chassis slots. For a review of the supported PCIe link 
configurations, please refer to the 

PXIe Chassis User Guide

 (available from the 

Windows 

Start

 button, then look under Keysight). 

For a detailed graphics, explaining the operation of the chassis PCIe data paths, 
see the 

Keysight PXIe Chassis Interactive Block Diagram

 at 

www.keysight.com/find/pxi-blockdiagram

.

Keysight’s M9035A embedded controller can boot and run with all of the PCIe 
switch fabric configurations supported by the M9018 chassis. The supported 
switch fabric configurations are:

- 1x8 Configuration 

— Referred to as 1x8, this configuration provides one x8 link 

from the M9035A embedded controller to the PCIe switch fabric. While the 
1x8 configuration will work with the M9035A, it is better suited for use with 
the M9021A system module which supports 8 PCIe lanes.

- 2x8 Configuration - 

Referred to as 2x8, this configuration provides two x8 links 

from the M9035A embedded controller to the PCIe switch fabric. The two x8 
links provide the highest performance I/O to the 18 chassis slots; therefore, 
the 2x8 configuration is recommended for use with the M9035A.

The default Administrator password is 

Keysight4u!

Keysight recommends that you change the password.

Summary of Contents for M9035A

Page 1: ...Keysight M9035A PXIe Embedded Controller Startup Guide...

Page 2: ......

Page 3: ...D IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EIT...

Page 4: ...with the equipment switched off To avoid dangerous elec trical shock DO NOT perform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Wh...

Page 5: ...Canada This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use Forty years is the expected useful life of thi...

Page 6: ...vi...

Page 7: ...Chassis Drivers 18 Step 4 Review Windows Configuration 19 Windows OS Versions 19 Microsoft Windows OS is Activated 19 Windows Security 19 Windows Update 19 User Data Backup 20 System Backup and Recov...

Page 8: ...viii Keysight M9035A PXIe Embedded Controller Startup Guide...

Page 9: ...35A documentation as well as the PXIe Chassis Family documentation is pre installed on the M9035A SSD It can be found from the Windows Start menu under Keysight Descriptions of the PXIe Chassis Family...

Page 10: ...information about the module follows in this manual DisplayPort Connectors GPIB USB 2 0 Ports LED Indicators USB 3 0 Ports Handle for LAN GbE Port 1 LAN GbE Port 2 Connector supports multiple monitors...

Page 11: ...f LAN RST Button The LAN RST button is reserved for Keysight use only Depressing the LAN RST button has no effect LED Indicator Color Description PWR Green If the LED is on the power supply to the con...

Page 12: ...ificant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provid...

Page 13: ...uipment Name and address of owner A Post Office box is not acceptable as a return address Product model number for example M9035A Product serial number for example TWXXXXXXXX The serial number label i...

Page 14: ...re drivers If possible you should connect the M9035A to the Internet and download drivers from the original source Alternately you can transfer the drivers on a USB memory stick and install them accor...

Page 15: ...xercise care when handling the module as the heat sink can get very hot Do not touch the heat sink when installing or removing the module The board should not be placed on any surface or in any form o...

Page 16: ...guide rails 6 Push inward on the module until it is firmly seated in the chassis Do not force the handle if there is resistance this may damage the connectors and or backplane 7 Pull up on the ejecto...

Page 17: ...with any PC Windows based instruments should not be shutdown by either turning off the power via an external power source or by pulling the power plug out from the chassis rear panel This could corru...

Page 18: ...M9035A web page www keysight com find M9035A for the most current M9035A software and drivers Likewise check the PXIe chassis web page for the latest PXIe Chassis Family Driver You cannot enable the...

Page 19: ...r If you want to verify Windows Activation do the following 1 In Windows 10 Enterprise LTSC right click Windows Start button then click System 2 Scroll down to the bottom of the screen Under Windows A...

Page 20: ...xposes the controller to periodic OS changes and possible new system behaviors Downloading and installing Windows Updates can be network and CPU intensive impacting system performance and some Windows...

Page 21: ...They Keysight standard for the Administrator password is Keysight4u Your M9035A Administrator account is most likely is set with this password If it is not set with this password then there is no pas...

Page 22: ...he accounts have passwords If your Administrator password is set on your M9035A then the Remote Desktop Connection is enabled by default Anyone with network access to your M9035A can control your M903...

Page 23: ...lready running run it now to verify your I O configuration From the Windows Start button select Keysight Connection Expert Alternately you can click the icon from the Windows messaging area in the low...

Page 24: ...tup Guide Step 6 Verify Operation Step 6 Verify Operation If your M9035A Embedded Controller boots to Windows and the front panel status LEDs do not indicate an error see Front Panel LED Indicators on...

Page 25: ...er operation but should install them on the controller at this time Consult the module provider for software requirements and instructions Static Electricity The components and connectors on modules a...

Page 26: ...tput and cables are not compatible The M9035A unlike the M9036A and M9037A does not have a Soft Front Panel or its own IVI drivers The PXIe chassis driver provides the IVI KtMTrig driver to provide Tr...

Page 27: ...Express signals between slot 1 the system controller slot and the other chassis slots For a review of the supported PCIe link configurations please refer to the PXIe Chassis User Guide available from...

Page 28: ...ile the 4x4 configuration will work with the M9035A it is more advantageous with certain non Keysight system modules Use the PCIe Switch Fabric Configurator utility to change the PCIe Switch Fabric of...

Page 29: ...Keysight M9036A PXIe Embedded Controller they are not compatible Y1261A Display Port to DVI adapter Y1262A DisplayPort cable Y1263A Display Port to VGA adapter Y1267A Spare SSD with Carrier Win10 64 b...

Page 30: ...hazard Condensation can occur when the module is moved from a cold to a warm environment or if the temperature and or humidity of the environment change quickly Samples of this product have been type...

Page 31: ...Keysight M9035A PXIe Embedded Controller Startup Guide 31...

Page 32: ...This information is subject to change without notice Keysight Technologies Inc 2021 Published in USA First Edition September 2021 M9035 90001 M9035 90001 www keysight com...

Reviews: