Step 3: Install the M9035A Embedded Controller

Step 3: Install the M9035A Embedded Controller

The Keysight M9035A has been designed for easy installation. However, the 
following standard precautions, installation procedures, and general information 
must be observed to ensure proper installation and to prevent damage to the 
board, other system components, or injury to personnel. 

Keysight’s M9035A can operate with all of the PCIe fabric configurations found 
on a Keysight PXIe chassis as well as the standard 4x4 fabric used on 
non-Keysight PXIe chassis.

The following safety precautions must be observed when installing or 

operating the Keysight M9035A. Exercise care when handling the module 

as the heat sink can get very hot. Do not touch the heat sink when 

installing or removing the module. The board should not be placed on any 

surface or in any form of storage container until the board and heat sink 

have cooled to room temperature.

Embedded controllers, such as the M9035A, can only be installed 
in System Controller slot (Slot 1) of the chassis.

M9018 PXIe Chassis Backplane Switch: 
The default position of the chassis backplane switch is to the left. 
However, if a Keysight M9021A Cable Interface module was 
previously installed in the M9018 chassis, then the backplane 
switch was moved to the right. To use the M9035A Embedded 
Controller in the M9018 chassis, the slide switch should be in the 
left position before installing the controller. Refer to the M9018 
chassis documentation for more information.

Ensure the M9018A/B
backplane switch is
in the left position

Summary of Contents for M9035A

Page 1: ...Keysight M9035A PXIe Embedded Controller Startup Guide...

Page 2: ......

Page 3: ...D IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EIT...

Page 4: ...with the equipment switched off To avoid dangerous elec trical shock DO NOT perform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Wh...

Page 5: ...Canada This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use Forty years is the expected useful life of thi...

Page 6: ...vi...

Page 7: ...Chassis Drivers 18 Step 4 Review Windows Configuration 19 Windows OS Versions 19 Microsoft Windows OS is Activated 19 Windows Security 19 Windows Update 19 User Data Backup 20 System Backup and Recov...

Page 8: ...viii Keysight M9035A PXIe Embedded Controller Startup Guide...

Page 9: ...35A documentation as well as the PXIe Chassis Family documentation is pre installed on the M9035A SSD It can be found from the Windows Start menu under Keysight Descriptions of the PXIe Chassis Family...

Page 10: ...information about the module follows in this manual DisplayPort Connectors GPIB USB 2 0 Ports LED Indicators USB 3 0 Ports Handle for LAN GbE Port 1 LAN GbE Port 2 Connector supports multiple monitors...

Page 11: ...f LAN RST Button The LAN RST button is reserved for Keysight use only Depressing the LAN RST button has no effect LED Indicator Color Description PWR Green If the LED is on the power supply to the con...

Page 12: ...ificant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provid...

Page 13: ...uipment Name and address of owner A Post Office box is not acceptable as a return address Product model number for example M9035A Product serial number for example TWXXXXXXXX The serial number label i...

Page 14: ...re drivers If possible you should connect the M9035A to the Internet and download drivers from the original source Alternately you can transfer the drivers on a USB memory stick and install them accor...

Page 15: ...xercise care when handling the module as the heat sink can get very hot Do not touch the heat sink when installing or removing the module The board should not be placed on any surface or in any form o...

Page 16: ...guide rails 6 Push inward on the module until it is firmly seated in the chassis Do not force the handle if there is resistance this may damage the connectors and or backplane 7 Pull up on the ejecto...

Page 17: ...with any PC Windows based instruments should not be shutdown by either turning off the power via an external power source or by pulling the power plug out from the chassis rear panel This could corru...

Page 18: ...M9035A web page www keysight com find M9035A for the most current M9035A software and drivers Likewise check the PXIe chassis web page for the latest PXIe Chassis Family Driver You cannot enable the...

Page 19: ...r If you want to verify Windows Activation do the following 1 In Windows 10 Enterprise LTSC right click Windows Start button then click System 2 Scroll down to the bottom of the screen Under Windows A...

Page 20: ...xposes the controller to periodic OS changes and possible new system behaviors Downloading and installing Windows Updates can be network and CPU intensive impacting system performance and some Windows...

Page 21: ...They Keysight standard for the Administrator password is Keysight4u Your M9035A Administrator account is most likely is set with this password If it is not set with this password then there is no pas...

Page 22: ...he accounts have passwords If your Administrator password is set on your M9035A then the Remote Desktop Connection is enabled by default Anyone with network access to your M9035A can control your M903...

Page 23: ...lready running run it now to verify your I O configuration From the Windows Start button select Keysight Connection Expert Alternately you can click the icon from the Windows messaging area in the low...

Page 24: ...tup Guide Step 6 Verify Operation Step 6 Verify Operation If your M9035A Embedded Controller boots to Windows and the front panel status LEDs do not indicate an error see Front Panel LED Indicators on...

Page 25: ...er operation but should install them on the controller at this time Consult the module provider for software requirements and instructions Static Electricity The components and connectors on modules a...

Page 26: ...tput and cables are not compatible The M9035A unlike the M9036A and M9037A does not have a Soft Front Panel or its own IVI drivers The PXIe chassis driver provides the IVI KtMTrig driver to provide Tr...

Page 27: ...Express signals between slot 1 the system controller slot and the other chassis slots For a review of the supported PCIe link configurations please refer to the PXIe Chassis User Guide available from...

Page 28: ...ile the 4x4 configuration will work with the M9035A it is more advantageous with certain non Keysight system modules Use the PCIe Switch Fabric Configurator utility to change the PCIe Switch Fabric of...

Page 29: ...Keysight M9036A PXIe Embedded Controller they are not compatible Y1261A Display Port to DVI adapter Y1262A DisplayPort cable Y1263A Display Port to VGA adapter Y1267A Spare SSD with Carrier Win10 64 b...

Page 30: ...hazard Condensation can occur when the module is moved from a cold to a warm environment or if the temperature and or humidity of the environment change quickly Samples of this product have been type...

Page 31: ...Keysight M9035A PXIe Embedded Controller Startup Guide 31...

Page 32: ...This information is subject to change without notice Keysight Technologies Inc 2021 Published in USA First Edition September 2021 M9035 90001 M9035 90001 www keysight com...

Reviews: