4. Connect Your M9021A to your Laptop or Desktop PC (optional)

If your solution contains an M9021A PXIe Cable Interface, you will find your adaptor and cable in one of the
accessory boxes.

If you are using a laptop as your controller, connect to your M9021A using the following components:

Keysight does not support the use of a laptop computer for controlling multiple PXIe chassis.

If you are using a desktop PC as your controller, connect to the M9021A using the following components:

5. Power up Your Solution

If you are using a remote controller and you have installed the interface cable, you must power up the chassis

BEFORE you power up the PC. When you power down your chassis, shut down the PC BEFORE you power
down the chassis.

Step 5: Redeem Your Software Licenses

The basic software required to operate your solution requires no license. This includes:

30

LTE/LTE-A Multi-Channel Reference Solution

Summary of Contents for LTE

Page 1: ...anced Multi Channel Reference Solution Notice This document contains references to Agilent Please note that Agilent s Test and Measurement busi ness has become Keysight Technologies For more informati...

Page 2: ......

Page 3: ...DFAR 252 227 7014 June 1995 or as a com mercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract...

Page 4: ...from the entire test system and discharge any capacitors before connecting or disconnecting cables or jumpers installing or removing switching cards or making internal changes such as installing or r...

Page 5: ...ed Protect the circuits from ESD damage by wearing a grounding strap that provides a high res istance path to ground Alternatively ground yourself to discharge any built up static charge by touching t...

Page 6: ......

Page 7: ...w 15 MIMO Instrument Connections 17 Recommended MIMO Configurations 18 Sharing the M9300A Frequency Reference 20 2x2 MIMO Configuration in a Single PXIe Chassis 22 3x3 MIMO Configuration in Two PXIe C...

Page 8: ......

Page 9: ...technique using the backplane of the PXIe chassis Refer to the Keysight M9391A PXIe Vector Signal Analyzer and M9381A PXIe Vector Signal Gen erator Programming Guide for details The scope of this doc...

Page 10: ...Depending upon your particular order you may find the following product documentation useful Keysight Multiple PXIe and AXIe Chassis System Configuration Tool Download and save this CHM file from www...

Page 11: ...volts Inspect for Damage After unpacking a solution inspect all components for any shipping damage Report any damage to the ship ping agent immediately as such damage is not covered by the warranty s...

Page 12: ...shipped in multiple boxes Refer to the box content list attached to each box Step 3 Install the Modules PXI hardware does not support hot swap changing modules while power is applied to the chassis c...

Page 13: ...M9018A has multiple air intakes They are located at the lower sides lower front and bottom of the chassis If Your Solution Contains a Keysight M9021A Cable Interface Module For greater detail on confi...

Page 14: ...supply those voltages to the connector The default position of the switch is to the left and does not supply the voltages to the connector To use the M9021A in Slot 1 of the M9018A chassis you must m...

Page 15: ...k the mounting screws out to ensure that there is no interference between the screws and the mounting rails 5 Refer to MIMO Instrument Connections page 17 for M9381A and M9391A cabling For MIMO config...

Page 16: ...A male Connect this adapter to the RF Out connector of each M9310A and torque to 8 Lb In 0 904 Nm This will extend the life of often used connector 10 Cable the system according to the information on...

Page 17: ...e coaxial SMB female SMB female 8120 5091 M9310A 100 MHz Out to M9311A 100 MHz In Cable coaxial SMB female SMB female 8120 5091 M9310A Trig 1 to M9311A Trig 1 for Pulse Mod Cable coaxial SMB female SM...

Page 18: ...onfiguration in Two PXIe Chassis with External Controller page 23 The next configuration consists of three receivers M9391A in a single M9018A Chassis with or without an M9036A M9037A PXIe Embedded Co...

Page 19: ...ingle chassis See the 3x3 or 4x4 configurations for module placements within a single chassis Placing the M9391A VSAs recommendation Install the M9391A VSA instruments in the chassis with the Keysight...

Page 20: ...ed before use so including it in all configurations allows applications to be started in any order However when sharing a module the user interface of some applications may not reflect M9300A settings...

Page 21: ...ed to the reference module in a shared default mode and you try to connect a second instance of the SFP to the same reference with ShareRe ferenceVisaSession 0 Advanced Option you will get the resourc...

Page 22: ...ut 1 to M9301A 100 MHz In slot 5 l 100 MHz Out 2 to M9301A 100 MHz In slot 7 l 100 MHz Out 3 to M9301A 100 MHz In slot 11 l 100 MHz Out 4 to M9301A 100 MHz In slot 18 2x2 MIMO Configuration with Exter...

Page 23: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 For the second bottom configuration master From the M9300A slot 10 use three 8...

Page 24: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 For the second bottom configuration master From the M9300A slot 10 use three 8...

Page 25: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 l 100 MHz Out 4 to M9301A 100 MHz In slot 18 For the second bottom configurati...

Page 26: ...Step 3 Install the Modules These configurations can be used for x4 source only or analyzer only configurations 26 LTE LTE A Multi Channel Reference Solution...

Page 27: ...z Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 l 100 MHz Out 4 to M9301A 100 MHz In slot 4 For the second bottom configuration master From the M9300A slot 10 use four...

Page 28: ...m slot link configuration l Run one of the operating systems listed in System Requirements above Remote con troller Keysight M9018A chassis only A PC running one of the operating systems listed in Sys...

Page 29: ...s Suite version 16 3 update 2 version 16 3 16603 3 or newer includes Keysight Connection Expert www keysight com find iosuite 2 M9018A 18 Slot PXIe Chassis Drivers www keysight com find M9018A 3 Keysi...

Page 30: ...computer for controlling multiple PXIe chassis If you are using a desktop PC as your controller connect to the M9021A using the following components 5 Power up Your Solution If you are using a remote...

Page 31: ...perability In this section you will run the Keysight MIMO Configuration Utility that you installed in Step 4 See 2 Install the Software page 29 After installing the files on the Keysight MIMO Accessor...

Page 32: ...instrument for repair To ensure that you send in the group of modules that was reported in a Self Test failure open the SFP and go to Utilities Calibration Options to view this screen The string point...

Page 33: ...river files are installed in the standard IVI Foundation dir ectories for example C Program Files IVI Foundation IVI Drivers AgM9391 Example programs are provided to demonstrate most driver functional...

Page 34: ......

Reviews: