3.2.2

 

Connection using an Adapterboard 

Recommended cable type between a Polyx and the Sirius card reader, using an Adapterboard 
is: 

 

Shielded cable with twisted pairs 
 

If  a  direct  connection  is  not  possible, 

an  Adapterboard  must  be  placed  between  Polyx  and  the 

Sirius card reader. 
Adapterboard  and  Polyx  are  connected  with  a  default  UTP  cat5  cable  (or  higher)  (plug 
connection). 
 
 
Connecting wires as shown in the diagrams below. 
 

Or

 screw connection 

on Adapterboard 

Or

 RJ45 

connection 

on 

Adapterboard  

TIA/EIA-568-B

 

Cable color 

Signal 

Connection 

Sirius i80 Sirius 

i80(/P) card 

reader 

A (or 1) 

White/orange 

B (or 2) 

Orange 

Y (or 3) 

White/green 

“+” 

Blue 

Vcc (+) 

 

White/blue 

 

 

Z (or 6) 

Green 

 

White/brown 

 

 

“—” 

Brown 

GND (-) 

 

 

Connect GND of the Adapterboard to the local Earth. 

 

Connect the shield of the ground cable to the GND connection of the Adapterboard. 

 

 

 Do 

not

 place any 

jumpers! 

For more information see the Adapterboard manual. 

 
 
 
 
 
 
 
 
 
           
Possible connections of the card reader Sirius on the Adapterboard 
 
 
 
 
 
 

Summary of Contents for Sirius i80

Page 1: ...Card reader Sirius i80 P Installation manual o Product o Installation o Connection o Technical data...

Page 2: ...MifareDesfire 4 1 3 2 Chip Serie nummer CSN 5 1 3 3 Sirius i 80 programmable using configuration cards 5 1 3 4 Sirius i 80 programmable using PS application and configuration cards 5 2 Installation a...

Page 3: ...activate the antenna when a person or card is detected near to the card reader This manual provides the necessary information concerning the installation instructions mounting and use of the card read...

Page 4: ...sed on RS485 An Orbit based on Clock Data MIFARE Classic MIFARE DESFire EV1 coded Output length when using Clock Data When using Mifare Classic the output length is 8 digits When using Mifare DESFire...

Page 5: ...ty When this function is needed you need to order another card reader See chapter 1 2 3 1 2 4 Programmable The card reader is not programmable 1 3 3 Sirius i 80 programmable using configuration cards...

Page 6: ...ader with a minimum lateral distance of 20 cm from each other 2 2 Mounting instructions Mount the card reader preferably on an outlet Picture 1 Sirius i80 measurements Pull the cable through the mount...

Page 7: ...2 3 Use of the i80 P When entering the PIN code the finger must be released at least 1 cm from the panel before the next digit is entered...

Page 8: ...f the conductor When using an external power supply it must comply with the SELV guidelines 3 2 If door controller Polyx The Sirius card reader can be connected in two ways with the Polyx directly or...

Page 9: ...a Polyx is NOT possible when Sirius and Polyx are installed in different buildings and thus the connection leaves the building or the wiring is no UTP cable CAT5 or CAT6 or an existing non UTP cable...

Page 10: ...n in the diagrams below Or screw connection on Adapterboard Or RJ45 connection on Adapterboard TIA EIA 568 B Cable color Signal Connection Sirius i80 Sirius i80 P card reader A or 1 1 White orange B 2...

Page 11: ...ductors 3 3 1 Connecting with UTP cable TIA EIA 568 B Cable color Connection on the Orbit Connection Sirius i80 card reader White orange Data D0 3 Orange White green Clock D1 4 Blue 5V 7 White blue LE...

Page 12: ...on both on 100 On 12V max 1 8W LED input LED input with pull up active low Ext output max Voltage 45V Open collector output sinked current Max current 500mA Ext input 1 Resistance 1kOhm Dimensions mm...

Page 13: ...signal Wiegand Interface Maximum cable length min conductor size with 12 VDC supply 1 5V DC Meters Feet mm2 AWG Wiegand 40 130 0 14 26 80 260 0 25 24 120 390 0 34 22 Clock Data 201 661 0 14 26 0 25 2...

Page 14: ...4 1 3 Data signal RS485...

Page 15: ...4 2 Certificates...

Reviews: