3.2.2
Connection using an Adapterboard
Recommended cable type between a Polyx and the Sirius card reader, using an Adapterboard
is:
Shielded cable with twisted pairs
If a direct connection is not possible,
an Adapterboard must be placed between Polyx and the
Sirius card reader.
Adapterboard and Polyx are connected with a default UTP cat5 cable (or higher) (plug
connection).
Connecting wires as shown in the diagrams below.
Or
screw connection
on Adapterboard
Or
RJ45
connection
on
Adapterboard
TIA/EIA-568-B
Cable color
Signal
Connection
Sirius i80 Sirius
i80(/P) card
reader
A (or 1)
1
White/orange
B
2
B (or 2)
2
Orange
A
1
Y (or 3)
3
White/green
B
2
“+”
4
Blue
Vcc (+)
7
5
White/blue
Z (or 6)
6
Green
A
1
7
White/brown
“—”
8
Brown
GND (-)
6
Connect GND of the Adapterboard to the local Earth.
Connect the shield of the ground cable to the GND connection of the Adapterboard.
Do
not
place any
jumpers!
For more information see the Adapterboard manual.
Possible connections of the card reader Sirius on the Adapterboard